U.S. flag

An official website of the United States government

Safe Drinking Water Information System (SDWIS) Federal Reporting Services

Your Drinking Water Query results from SDWIS Fed Reporting Services

PWS IDVA2820775
PWS NameWAYNESBORO, CITY OF
PWS TypeCommunity water system
Owner TypeLocal government
Primary SourceGroundwater under influence of surface water
Primacy TypeState
Is Wholesaler?No
Population Served22630
County Served

Note


The tables below list all violations that the state reported to EPA for this water system. Health-based violations are listed first, followed by treatment technique, MRDL, monitoring, reporting, and other violations.

Health-based Violations of maximum contaminant levels (MCLs) or maximum residual disinfectant levels (MRDLs), which specify the highest concentrations of contaminants or disinfectants, respectively, allowed in drinking water; or of treatment technique (TT) rules, which specify required processes intended to reduce the amounts of contaminants in drinking water. MCLs, MRDLs, and treatment technique rules are all health-based drinking water standards.
Maximum Contaminant Level or MCL The highest level of a contaminant that is allowed in drinking water. MCLs are set as close to the MCLGs as feasible using the best available treatment technology.
Treatment Technique A required process intended to reduce the level of a contaminant in drinking water.
Maximum residual disinfectant level or MRDL The highest level of a disinfectant allowed in drinking water. There is convincing evidence that addition of a disinfectant is necessary for control of microbial contaminants.
Monitoring & reporting Failure to conduct regular monitoring of drinking water quality, as required by SDWA, or to submit monitoring results in a timely fashion to the primacy agency or EPA.
Public notification & other Failure to provide notification to the public as required by the Violations of Public Notification Rule and the Consumer Confidence Report Rule, and violations of other requirements such as those violations related to variances and exemptions.

PWS Violation


Violations

Violation Category CodeViolation Type DescriptionRule NameContaminant NameViolation IDCompliance Status DescriptionCompliance Period Begin DateCompliance Period End DateIs Health Based Ind
MRMonitoring of Treatment (SWTR-Filter)Surface Water Treatment RuleSurface Water Treatment Rule2321914Returned to Compliance01-JUL-202231-JUL-2022No
MRLead Consumer NoticeLead and Copper RuleLead and Copper Rule2321915Returned to Compliance01-JUN-2022 - No
MCLMaximum Contaminant Level Violation, Monthly (TCR)Total Coliform RuleColiform (TCR)2321913Returned to Compliance01-SEP-201530-SEP-2015Yes
MRMonitoring, Routine (IDSE)Stage 2 Disinfectants and Disinfection Byproducts RuleTTHM2321911Returned to Compliance01-APR-201530-JUN-2015No
MRMonitoring, Routine (IDSE)Stage 2 Disinfectants and Disinfection Byproducts RuleTotal Haloacetic Acids (HAA5)2321912Returned to Compliance01-APR-201530-JUN-2015No
MRMonitoring, Source Water (LT2)Long Term 2 Enhanced Surface Water Treatment RuleLong Term 2 Enhanced Surface Water Treatment Rule2321908Returned to Compliance01-JAN-2008 - No
MCLMaximum Contaminant Level Violation, Monthly (TCR)Total Coliform RuleColiform (TCR)2321806Returned to Compliance01-AUG-200631-AUG-2006Yes
MCLMaximum Contaminant Level Violation, Monthly (TCR)Total Coliform RuleColiform (TCR)2321705Returned to Compliance01-JUL-200531-JUL-2005Yes
MCLMaximum Contaminant Level Violation, Monthly (TCR)Total Coliform RuleColiform (TCR)2321592Known01-JUL-199231-JUL-1992Yes
MCLMaximum Contaminant Level Violation, Monthly (TCR)Total Coliform RuleColiform (TCR)2315591Known01-AUG-199131-AUG-1991Yes
  • 1 - 10 of 10

Enforcement Actions


Enforcement Actions

Latest Enforcement IDAssociated To Violation IDEnforcement Action Type CodeEnforcement Action DescriptionEnforcement DateOriginator DescriptionEnforcement Comment
12332321914SIFState Public Notification received22-MAY-2023State -
12312321915SFJState Formal Notice of Violation issued21-SEP-2022State -
12262321913SOXState Compliance achieved29-OCT-2015State -
12232321912SOXState Compliance achieved11-AUG-2015State -
12202321911SOXState Compliance achieved11-AUG-2015State -
12122321908SIFState Public Notification received06-FEB-2009State -
11062321806SOXState Compliance achieved20-SEP-2006State -
12162321705SOXState Compliance achieved13-OCT-2005State -
4E922321592SIFState Public Notification received08-SEP-1992State -
5E912315591SIFState Public Notification received27-SEP-1991State -
  • 1 - 10 of 10

PWS Facilities


All Facilities

Facility NameFacility IDIs SourceFacility Type DescriptionWater Type DescriptionAvailability DescriptionFacility Activity Status
METER VAULT - SOUTH RIVER36493YesConsecutive ConnectionSurface waterEmergencyActive
B STREET WELL18729YesWell Ground waterPermanentInactive
JEFFERSON WELL 15902YesWell Ground waterPermanentActive
JEFFERSON WELL 218728YesWell Ground waterPermanentActive
DISTRICT HOME14620YesSpringGround water under the influence of surface waterPermanentInactive
COYNER SPRINGS14626YesSpringGround water under the influence of surface waterPermanentActive
WAYNESBORO21410NoDistribution System/Zone - - Active
FAIRFAX HALL PUMP STATION40204NoPump Facility - - Active
SHENANDOAH VILLAGE DRIVE PUMP STATION40205NoPump Facility - - Active
HOPEMAN PARKWAY PUMP STATION40206NoPump Facility - - Active
COYNER SPRINGS ENTRY POINT19301NoSampling Station - - Active
JEFFERSON WELL 1 ENTRY POINT19302NoSampling Station - - Inactive
JEFFERSON WELL 2 ENTRY POINT21772NoSampling Station - - Inactive
B STREET WELL ENTRY POINT21773NoSampling Station - - Inactive
2MG MAUPINTOWN RESERVOIR40199NoStorage - - Active
1MG RED TOP ORCHARD TANK40200NoStorage - - Active
1MG LANDFILL TANK40201NoStorage - - Active
500K WAYNE HILLS TANK40202NoStorage - - Active
300K MONDOMAIN TANK40203NoStorage - - Active
COYNER SPRINGS WTP5069NoTreatment Plant - - Active
DISTRICT HOME5794NoTreatment Plant - - Inactive
JEFFERSON STREET WELL6029NoTreatment Plant - - Inactive
  • 1 - 22 of 22

PWS Treatment Processes


Treatment Processes

Facility NameFacility IDTreatment ProcessTreatment Objective
COYNER SPRINGS WTP5069Hypochlorination, PostDisinfection
COYNER SPRINGS WTP5069FluoridationOther
COYNER SPRINGS WTP50694-Log Treatment of VirusesDisinfection
COYNER SPRINGS WTP5069Filtration, UltrafiltrationParticulate removal
JEFFERSON STREET WELL6029Hypochlorination, PostDisinfection
JEFFERSON STREET WELL6029FluoridationOther
  • 1 - 6 of 6

For more information on a Water System:
Ask the operators of your water system, contact your primacy agency or file a Freedom of Information Act (FOIA) request.
Drinking water in general: Find out more about your drinking water web site or call the Safe Drinking Water Hotline (1-800-426-4791). EPA has also prepared a table about various regulated drinking water contaminants.
Tools for accessing EPA drinking water data: Safe Drinking Water Information System (SDWIS) Federal Reporting Services and Drinking Water Performance and Results Report.
Research Data: As well as monitoring the levels of drinking water contaminants for which EPA has set standards, EPA, states, and water systems also carry out studies of contaminants that may need to be regulated in the future. For more information about these contaminants, please see the National Contaminant Occurrence Database.