U.S. flag

An official website of the United States government

Safe Drinking Water Information System (SDWIS) Federal Reporting Services

Your Drinking Water Query results from SDWIS Fed Reporting Services

PWS IDTX2460003
PWS NameCITY OF ROUND ROCK
PWS TypeCommunity water system
Owner TypeLocal government
Primary SourceSurface water
Primacy TypeState
Is Wholesaler?Yes
Population Served130662
County ServedWilliamson

Note


The tables below list all violations that the state reported to EPA for this water system. Health-based violations are listed first, followed by treatment technique, MRDL, monitoring, reporting, and other violations.

Health-based Violations of maximum contaminant levels (MCLs) or maximum residual disinfectant levels (MRDLs), which specify the highest concentrations of contaminants or disinfectants, respectively, allowed in drinking water; or of treatment technique (TT) rules, which specify required processes intended to reduce the amounts of contaminants in drinking water. MCLs, MRDLs, and treatment technique rules are all health-based drinking water standards.
Maximum Contaminant Level or MCL The highest level of a contaminant that is allowed in drinking water. MCLs are set as close to the MCLGs as feasible using the best available treatment technology.
Treatment Technique A required process intended to reduce the level of a contaminant in drinking water.
Maximum residual disinfectant level or MRDL The highest level of a disinfectant allowed in drinking water. There is convincing evidence that addition of a disinfectant is necessary for control of microbial contaminants.
Monitoring & reporting Failure to conduct regular monitoring of drinking water quality, as required by SDWA, or to submit monitoring results in a timely fashion to the primacy agency or EPA.
Public notification & other Failure to provide notification to the public as required by the Violations of Public Notification Rule and the Consumer Confidence Report Rule, and violations of other requirements such as those violations related to variances and exemptions.

PWS Violation


Violations

Violation Category CodeViolation Type DescriptionRule NameContaminant NameViolation IDCompliance Status DescriptionCompliance Period Begin DateCompliance Period End DateIs Health Based Ind
MRMonitoring, RegularNitrate RuleNitrate420Returned to Compliance01-JUL-201130-SEP-2011No
TTTreatment Technique (SWTR and GWR)Surface Water Treatment RuleSurface Water Treatment Rule105Returned to Compliance01-DEC-200431-DEC-2004Yes
MRMonitoring, Turbidity (Enhanced SWTR)Interim and Long Term 1 Enhanced Surface Water Treatment RuleInterim Enhanced Surface Water Treatment Rule204Returned to Compliance01-NOV-200330-NOV-2003No
MCLMaximum Contaminant Level Violation, AverageStage 1 Disinfectants and Disinfection Byproducts RuleTotal Haloacetic Acids (HAA5)403Returned to Compliance01-JAN-200331-MAR-2003Yes
MCLMaximum Contaminant Level Violation, AverageStage 1 Disinfectants and Disinfection Byproducts RuleTotal Haloacetic Acids (HAA5)303Returned to Compliance01-OCT-200231-DEC-2002Yes
  • 1 - 5 of 5

Enforcement Actions


Enforcement Actions

Latest Enforcement IDAssociated To Violation IDEnforcement Action Type CodeEnforcement Action DescriptionEnforcement DateOriginator DescriptionEnforcement Comment
811420SOXState Compliance achieved13-APR-2015State20150413; MMELICK; RECEIVED 4Q2011 RESULTS
808303SOXState Compliance achieved03-SEP-2013State09/03/2013; Ctaylor; Levels under MCL
808403SOXState Compliance achieved03-SEP-2013State09/03/2013; Ctaylor; Levels under MCL
809204SOXState Compliance achieved09-NOV-2006State -
810105SOXState Compliance achieved01-FEB-2005StatePWS HAS MET REQUIREMENTS TO RETURN TO COMPLIANCE.
  • 1 - 5 of 5

PWS Facilities


All Facilities

Facility NameFacility IDIs SourceFacility Type DescriptionWater Type DescriptionAvailability DescriptionFacility Activity Status
SW FROM CITY OF AUSTIN145421YesConsecutive ConnectionSurface waterEmergencyActive
2 - LAKE CREEK / PLUGGED25251YesWell Ground waterPermanentInactive
9 - CHISHOLM TRL / PLUGGED25247YesWell Ground waterPermanentInactive
8 - CHISHOLM TRL / PLUGGED25246YesWell Ground waterPermanentInactive
6 - PECAN ST25244YesWell Ground waterPermanentInactive
5 - TOWER DR / PLUGGED25243YesWell Ground waterPermanentInactive
1 - LAKE CREEK PS / 501 N MAYS ST25248YesWell Ground waterPermanentActive
4 - LAKE CREEK PS / 501 N MAYS ST25242YesWell Ground waterPermanentActive
3 - LAKE CREEK PS / 501 N MAYS ST25191YesWell Ground waterPermanentActive
7 - 501 SPRING ST25245YesWell Ground waterOtherInactive
12 - NORTH / WESTINGHOUSE RD25220YesWell Ground waterOtherInactive
WSC25209YesWell Ground waterOtherInactive
10 - GATTIS SCHOOL R25183YesWell Ground waterOtherInactive
11 - SOUTH / WESTINGHOUSE RD25181YesWell Ground waterOtherInactive
INTAKE 1 - LAKE GEORGETOWN33900YesIntakeSurface waterPermanentActive
SW FROM CITY OF GEORGETOWN145459YesConsecutive ConnectionSurface waterEmergencyActive
SW FROM BRUSHY CREEK REGIONAL AUTHORITY145420YesConsecutive ConnectionSurface waterPermanentActive
RAW-TAP117785NoCommon Headers - - Active
SWTP - 1 MG - CW123184NoClear Well - - Active
SWTP - 2 MG - CW123185NoClear Well - - Active
SWTP - 2 MG - CW123186NoClear Well - - Active
SWTP - 1.5 MG - CW150388NoClear Well - - Active
DISTRIBUTION SYSTEM46364NoDistribution System/Zone - - Active
4300 STONE OAK - 600 GPM SP112939NoPump Facility - - Active
505 BOWMAN RD - 1500 GPM SP121657NoPump Facility - - Active
2303 S MAYS ST - 3500 GPM - SP130741NoPump Facility - - Active
2303 S MAYS ST -3500 GPM - SP130742NoPump Facility - - Active
WTP - 5200 GPM SP79090NoPump Facility - - Active
WTP - 5200 GPM SP79091NoPump Facility - - Active
WTP - 5200 GPM SP79092NoPump Facility - - Active
WTP - 4200 GPM SP79093NoPump Facility - - Active
WTP - 4200 GPM SP79094NoPump Facility - - Active
WTP - 2100 GPM SP79095NoPump Facility - - Active
WTP - 2100 GPM SP79096NoPump Facility - - Active
WTP - 2100 GPM SP79097NoPump Facility - - Active
WTP - 2100 GPM SP79098NoPump Facility - - Active
WESTINGHOUSE RD - 1200 GPM SP79099NoPump Facility - - Active
501 N MAYS ST (LAKE CREEK) - 2000 GPM SP79100NoPump Facility - - Active
1829 S MAYS ST (TOWER) - 1200 GPM SP79101NoPump Facility - - Active
1331 TREY ST (MCNEIL) - 1500 GPM SP79102NoPump Facility - - Active
SYCAMORE TRAIL & MOKAN - 3000 GPM SP79103NoPump Facility - - Active
2029 DOUBLE CREEK DR - 3000 GPM SP79104NoPump Facility - - Active
501 N MAYS ST (LAKE CREEK) - 2000 GPM SP82095NoPump Facility - - Active
501 N MAYS ST (LAKE CREEK) - 2000 GPM SP82096NoPump Facility - - Active
501 N MAYS ST (LAKE CREEK) - 2000 GPM SP82097NoPump Facility - - Active
501 N MAYS ST (LAKE CREEK) - 2000 GPM SP82098NoPump Facility - - Active
501 N MAYS ST (LAKE CREEK) - 2000 GPM SP82099NoPump Facility - - Active
1829 S MAYS ST (TOWER) - 1200 GPM SP82241NoPump Facility - - Active
1829 S MAYS ST (TOWER) - 1200 GPM SP82441NoPump Facility - - Active
1331 TREY ST (MCNEIL) - 1500 GPM SP82511NoPump Facility - - Active
  • 1 - 50 of 96

PWS Treatment Processes


Treatment Processes

Facility NameFacility IDTreatment ProcessTreatment Objective
SWTP I - PHASE III, IV, VA, VB10102InnovativeDisinfection
SWTP I - PHASE III, IV, VA, VB10102InnovativeDisinfection
SWTP I - PHASE III, IV, VA, VB10102InnovativeDisinfection
SWTP I - PHASE III, IV, VA, VB10102InnovativeDisinfection
SWTP I - PHASE III, IV, VA, VB10102Gaseous Chlorination, PreDisinfection
SWTP I - PHASE III, IV, VA, VB10102Gaseous Chlorination, PreDisinfection
SWTP I - PHASE III, IV, VA, VB10102Gaseous Chlorination, PreDisinfection
SWTP I - PHASE III, IV, VA, VB10102Gaseous Chlorination, PreDisinfection
SWTP I - PHASE III, IV, VA, VB10102Rapid MixParticulate removal
SWTP I - PHASE III, IV, VA, VB10102Rapid MixParticulate removal
SWTP I - PHASE III, IV, VA, VB10102Rapid MixParticulate removal
SWTP I - PHASE III, IV, VA, VB10102Rapid MixParticulate removal
SWTP I - PHASE III, IV, VA, VB10102CoagulationParticulate removal
SWTP I - PHASE III, IV, VA, VB10102CoagulationParticulate removal
SWTP I - PHASE III, IV, VA, VB10102CoagulationParticulate removal
SWTP I - PHASE III, IV, VA, VB10102CoagulationParticulate removal
SWTP I - PHASE III, IV, VA, VB10102CoagulationParticulate removal
SWTP I - PHASE III, IV, VA, VB10102CoagulationParticulate removal
SWTP I - PHASE III, IV, VA, VB10102CoagulationParticulate removal
SWTP I - PHASE III, IV, VA, VB10102CoagulationParticulate removal
SWTP I - PHASE III, IV, VA, VB10102InnovativeParticulate removal
SWTP I - PHASE III, IV, VA, VB10102InnovativeParticulate removal
SWTP I - PHASE III, IV, VA, VB10102InnovativeParticulate removal
SWTP I - PHASE III, IV, VA, VB10102InnovativeParticulate removal
SWTP I - PHASE III, IV, VA, VB10102InnovativeParticulate removal
SWTP I - PHASE III, IV, VA, VB10102InnovativeParticulate removal
SWTP I - PHASE III, IV, VA, VB10102InnovativeParticulate removal
SWTP I - PHASE III, IV, VA, VB10102InnovativeParticulate removal
SWTP I - PHASE III, IV, VA, VB10102InnovativeDisinfection
SWTP I - PHASE III, IV, VA, VB10102InnovativeDisinfection
SWTP I - PHASE III, IV, VA, VB10102InnovativeDisinfection
SWTP I - PHASE III, IV, VA, VB10102InnovativeDisinfection
SWTP I - PHASE III, IV, VA, VB10102InnovativeDisinfection
SWTP I - PHASE III, IV, VA, VB10102InnovativeDisinfection
SWTP I - PHASE III, IV, VA, VB10102InnovativeDisinfection
SWTP I - PHASE III, IV, VA, VB10102InnovativeDisinfection
SWTP I - PHASE III, IV, VA, VB10102Gaseous Chlorination, PreDisinfection
SWTP I - PHASE III, IV, VA, VB10102Gaseous Chlorination, PreDisinfection
SWTP I - PHASE III, IV, VA, VB10102Gaseous Chlorination, PreDisinfection
SWTP I - PHASE III, IV, VA, VB10102Gaseous Chlorination, PreDisinfection
SWTP I - PHASE III, IV, VA, VB10102Filtration, Rapid SandParticulate removal
SWTP I - PHASE III, IV, VA, VB10102Filtration, Rapid SandParticulate removal
SWTP I - PHASE III, IV, VA, VB10102Filtration, Rapid SandParticulate removal
SWTP I - PHASE III, IV, VA, VB10102Filtration, Rapid SandParticulate removal
SWTP I - PHASE III, IV, VA, VB10102InnovativeDisinfection
SWTP I - PHASE III, IV, VA, VB10102InnovativeDisinfection
SWTP I - PHASE III, IV, VA, VB10102InnovativeDisinfection
SWTP I - PHASE III, IV, VA, VB10102InnovativeDisinfection
SWTP I - PHASE III, IV, VA, VB10102Gaseous Chlorination, PostDisinfection
SWTP I - PHASE III, IV, VA, VB10102Gaseous Chlorination, PostDisinfection
  • 1 - 50 of 72

For more information on a Water System:
Ask the operators of your water system, contact your primacy agency or file a Freedom of Information Act (FOIA) request.
Drinking water in general: Find out more about your drinking water web site or call the Safe Drinking Water Hotline (1-800-426-4791). EPA has also prepared a table about various regulated drinking water contaminants.
Tools for accessing EPA drinking water data: Safe Drinking Water Information System (SDWIS) Federal Reporting Services and Drinking Water Performance and Results Report.
Research Data: As well as monitoring the levels of drinking water contaminants for which EPA has set standards, EPA, states, and water systems also carry out studies of contaminants that may need to be regulated in the future. For more information about these contaminants, please see the National Contaminant Occurrence Database.