U.S. flag

An official website of the United States government

Safe Drinking Water Information System (SDWIS) Federal Reporting Services

Your Drinking Water Query results from SDWIS Fed Reporting Services

PWS IDTX2120024
PWS NameWALNUT GROVE WSC
PWS TypeCommunity water system
Owner TypeLocal government
Primary SourceSurface water purchased
Primacy TypeState
Is Wholesaler?No
Population Served8775
County ServedSmith

Note


The tables below list all violations that the state reported to EPA for this water system. Health-based violations are listed first, followed by treatment technique, MRDL, monitoring, reporting, and other violations.

Health-based Violations of maximum contaminant levels (MCLs) or maximum residual disinfectant levels (MRDLs), which specify the highest concentrations of contaminants or disinfectants, respectively, allowed in drinking water; or of treatment technique (TT) rules, which specify required processes intended to reduce the amounts of contaminants in drinking water. MCLs, MRDLs, and treatment technique rules are all health-based drinking water standards.
Maximum Contaminant Level or MCL The highest level of a contaminant that is allowed in drinking water. MCLs are set as close to the MCLGs as feasible using the best available treatment technology.
Treatment Technique A required process intended to reduce the level of a contaminant in drinking water.
Maximum residual disinfectant level or MRDL The highest level of a disinfectant allowed in drinking water. There is convincing evidence that addition of a disinfectant is necessary for control of microbial contaminants.
Monitoring & reporting Failure to conduct regular monitoring of drinking water quality, as required by SDWA, or to submit monitoring results in a timely fashion to the primacy agency or EPA.
Public notification & other Failure to provide notification to the public as required by the Violations of Public Notification Rule and the Consumer Confidence Report Rule, and violations of other requirements such as those violations related to variances and exemptions.

PWS Violation


Violations

Violation Category CodeViolation Type DescriptionRule NameContaminant NameViolation IDCompliance Status DescriptionCompliance Period Begin DateCompliance Period End DateIs Health Based Ind
OtherConsumer Confidence Report Inadequate ReportingConsumer Confidence RuleConsumer Confidence Rule90062006Open01-JUL-2025 - No
MCLMaximum Contaminant Level Violation, AverageStage 2 Disinfectants and Disinfection Byproducts RuleTTHM90062000Returned to Compliance01-APR-201630-JUN-2016Yes
MCLMaximum Contaminant Level Violation, AverageStage 2 Disinfectants and Disinfection Byproducts RuleTTHM90061999Returned to Compliance01-JAN-201631-MAR-2016Yes
MCLMaximum Contaminant Level Violation, Acute (TCR)Total Coliform RuleColiform (TCR)90061993Returned to Compliance01-OCT-201531-OCT-2015Yes
MCLMaximum Contaminant Level Violation, AverageStage 2 Disinfectants and Disinfection Byproducts RuleTTHM90061990Returned to Compliance01-OCT-201431-DEC-2014Yes
MRLead Consumer NoticeLead and Copper RuleLead and Copper Rule90061927Returned to Compliance30-DEC-2013 - No
MCLMaximum Contaminant Level Violation, AverageStage 1 Disinfectants and Disinfection Byproducts RuleTTHM408Returned to Compliance01-APR-200830-JUN-2008Yes
MCLMaximum Contaminant Level Violation, AverageStage 1 Disinfectants and Disinfection Byproducts RuleTTHM308Returned to Compliance01-JAN-200831-MAR-2008Yes
MCLMaximum Contaminant Level Violation, AverageStage 1 Disinfectants and Disinfection Byproducts RuleTTHM208Returned to Compliance01-OCT-200731-DEC-2007Yes
MCLMaximum Contaminant Level Violation, AverageStage 1 Disinfectants and Disinfection Byproducts RuleTTHM108Returned to Compliance01-JUL-200730-SEP-2007Yes
MRInitial Tap Sampling for Pb and CuLead and Copper RuleLead and Copper Rule9999193Returned to Compliance01-JUL-199230-JUN-1993No
MCLMaximum Contaminant Level Violation, Monthly (TCR)Total Coliform RuleColiform (TCR)3099692Known01-APR-199230-APR-1992Yes
  • 1 - 12 of 12

Enforcement Actions


Enforcement Actions

Latest Enforcement IDAssociated To Violation IDEnforcement Action Type CodeEnforcement Action DescriptionEnforcement DateOriginator DescriptionEnforcement Comment
9009289690062006SIAState Violation/Reminder Notice31-DEC-2025State -
9009289290061999SOXState Compliance achieved26-SEP-2016State10/20/16;PER 3Q2016 TTHM DBP2-01 LRAA SOX'D PREVIOUS VIOLATIONS
9009289290062000SOXState Compliance achieved26-SEP-2016State10/20/16;PER 3Q2016 TTHM DBP2-01 LRAA SOX'D PREVIOUS VIOLATIONS
9009288290061993SFOState Administrative/Compliance Order with penalty issued13-JUL-2016StateDOCKET NO 2015-1743-PWS-E;
9009288290061927SFOState Administrative/Compliance Order with penalty issued13-JUL-2016StateDOCKET NO 2015-1743-PWS-E;
9009286590061990SOXState Compliance achieved27-MAR-2015State03/27/15; SYSTEM HAS COME BACK INTO COMPLIANCE WITH 1Q 2015 DBP DATA, PAST VIOLATIONS HAVE BEEN SOXED
90092849408SOXState Compliance achieved01-JUL-2010StateSDWIS 2010 CLEANUP
90092849308SOXState Compliance achieved01-JUL-2010StateSDWIS 2010 CLEANUP
90092849108SOXState Compliance achieved01-JUL-2010StateSDWIS 2010 CLEANUP
90092849208SOXState Compliance achieved01-JUL-2010StateSDWIS 2010 CLEANUP
1939999193SOXState Compliance achieved30-JUN-1993State -
  • 1 - 11 of 11

PWS Facilities


All Facilities

Facility NameFacility IDIs SourceFacility Type DescriptionWater Type DescriptionAvailability DescriptionFacility Activity Status
GW FROM NORTH CHEROKEE65296YesConsecutive ConnectionGround waterEmergencyActive
3 - JOYE LN / PLUGGED26663YesWell Ground waterPermanentInactive
7 - GANDY MOUNTAIN RD / PLUGGED26658YesWell Ground waterPermanentInactive
4 - CR 2173 / PLUGGED26655YesWell Ground waterPermanentInactive
2 - FM 246 / FM 2964 (PLUGGED)26653YesWell Ground waterPermanentInactive
1 - FM 756 / CR 2173 (PLUGGED)26652YesWell Ground waterPermanentInactive
5 - CR 2173 / E OF PLANT 126606YesWell Ground waterPermanentActive
10 - CARL DOWDY RD167066YesWell Ground waterPermanentActive
9 - JOYE LN26670YesWell Ground waterEmergencyActive
6 - FM 756 / CR 1526657YesWell Ground waterEmergencyActive
SURFACE WATER FROM SOUTHERN UTILITIES35815YesConsecutive ConnectionSurface waterEmergencyActive
GW FROM CITY OF TYLER35816YesConsecutive ConnectionSurface waterPermanentActive
DISTRIBUTION SYSTEM45248NoDistribution System/Zone - - Active
DOWDY - 300 GPM - SP121819NoPump Facility - - Active
DOWDY - 300 GPM - SP121824NoPump Facility - - Active
FM 2964 - 550 GPM - SP75829NoPump Facility - - Active
FM 2964 - 550 GPM - SP75830NoPump Facility - - Active
JOYE PLANT - 924 GPM-SP121827NoPump Facility - - Inactive
JOYE PLANT - 924 GPM-SP121830NoPump Facility - - Inactive
PLANTS 1; 5139910NoSampling Station - - Active
JOYE LN139911NoSampling Station - - Active
PLANT 8139912NoSampling Station - - Active
EP007141803NoSampling Station - - Active
PLANTS 1, 5- 9689 CR2173, WHITEHOUSE58129NoSampling Station - - Active
JOYE LN58130NoSampling Station - - Active
PLANT 8-17018 FM2964, WHITEHOUSE61697NoSampling Station - - Active
EP00765355NoSampling Station - - Active
EP00358131NoSampling Station - - Inactive
EP00460786NoSampling Station - - Inactive
EP00561230NoSampling Station - - Inactive
FM 2964 - 0.25 MG - GR93142NoStorage - - Active
CR 2182 / GANDY MT - 0.103 MG - ST93143NoStorage - - Active
CR 2173 / DOWDY - 0.100 MG - EL93144NoStorage - - Active
DOWDY - 0.063 MG - GR93145NoStorage - - Active
DOWDY - 0.040 MG - GR93146NoStorage - - Active
CR 15 - 0.100 MG - EL93147NoStorage - - Active
JOYE PLANT - 0.063 MG - GR93148NoStorage - - Active
JOYE PLANT - 0.041 MG- GR93149NoStorage - - Active
NORTH CHEROKEE DIRECT PRESSURE66107NoTransmission Main (Manifold) - - Inactive
PLANT 8 - FM 296412523NoTreatment Plant - - Active
PLANT - DOWDY / CR 21737983NoTreatment Plant - - Active
PLANT - JOYE LN8378NoTreatment Plant - - Active
PLANT 2 - FM 34663275NoTreatment Plant - - Inactive
PLANT - WELL 48429NoTreatment Plant - - Inactive
PLANT 5 - GANDY MT8455NoTreatment Plant - - Inactive
  • 1 - 45 of 45

PWS Treatment Processes


Treatment Processes

Facility NameFacility IDTreatment ProcessTreatment Objective
PLANT 8 - FM 296412523Gaseous Chlorination, PreDisinfection
PLANT 8 - FM 296412523ChloraminesDisinfection
PLANT - DOWDY / CR 21737983Gaseous Chlorination, PreDisinfection
PLANT - DOWDY / CR 21737983ChloraminesDisinfection
PLANT - JOYE LN8378Gaseous Chlorination, PreDisinfection
PLANT - JOYE LN8378Inhibitor, PolyphosphateIron removal
PLANT - JOYE LN8378ChloraminesDisinfection
PLANT - WELL 48429Gaseous Chlorination, PreDisinfection
  • 1 - 8 of 8

For more information on a Water System:
Ask the operators of your water system, contact your primacy agency or file a Freedom of Information Act (FOIA) request.
Drinking water in general: Find out more about your drinking water web site or call the Safe Drinking Water Hotline (1-800-426-4791). EPA has also prepared a table about various regulated drinking water contaminants.
Tools for accessing EPA drinking water data: Safe Drinking Water Information System (SDWIS) Federal Reporting Services and Drinking Water Performance and Results Report.
Research Data: As well as monitoring the levels of drinking water contaminants for which EPA has set standards, EPA, states, and water systems also carry out studies of contaminants that may need to be regulated in the future. For more information about these contaminants, please see the National Contaminant Occurrence Database.