U.S. flag

An official website of the United States government

Safe Drinking Water Information System (SDWIS) Federal Reporting Services

Your Drinking Water Query results from SDWIS Fed Reporting Services

PWS IDTX1090041
PWS NameHILL COUNTY WSC
PWS TypeCommunity water system
Owner TypeLocal government
Primary SourceSurface water purchased
Primacy TypeState
Is Wholesaler?Yes
Population Served4383
County ServedHill

Note


The tables below list all violations that the state reported to EPA for this water system. Health-based violations are listed first, followed by treatment technique, MRDL, monitoring, reporting, and other violations.

Health-based Violations of maximum contaminant levels (MCLs) or maximum residual disinfectant levels (MRDLs), which specify the highest concentrations of contaminants or disinfectants, respectively, allowed in drinking water; or of treatment technique (TT) rules, which specify required processes intended to reduce the amounts of contaminants in drinking water. MCLs, MRDLs, and treatment technique rules are all health-based drinking water standards.
Maximum Contaminant Level or MCL The highest level of a contaminant that is allowed in drinking water. MCLs are set as close to the MCLGs as feasible using the best available treatment technology.
Treatment Technique A required process intended to reduce the level of a contaminant in drinking water.
Maximum residual disinfectant level or MRDL The highest level of a disinfectant allowed in drinking water. There is convincing evidence that addition of a disinfectant is necessary for control of microbial contaminants.
Monitoring & reporting Failure to conduct regular monitoring of drinking water quality, as required by SDWA, or to submit monitoring results in a timely fashion to the primacy agency or EPA.
Public notification & other Failure to provide notification to the public as required by the Violations of Public Notification Rule and the Consumer Confidence Report Rule, and violations of other requirements such as those violations related to variances and exemptions.

PWS Violation


Violations

Violation Category CodeViolation Type DescriptionRule NameContaminant NameViolation IDCompliance Status DescriptionCompliance Period Begin DateCompliance Period End DateIs Health Based Ind
MCLMaximum Contaminant Level Violation, AverageStage 1 Disinfectants and Disinfection Byproducts RuleTTHM505Returned to Compliance01-APR-200530-JUN-2005Yes
MCLMaximum Contaminant Level Violation, AverageStage 1 Disinfectants and Disinfection Byproducts RuleTotal Haloacetic Acids (HAA5)605Returned to Compliance01-APR-200530-JUN-2005Yes
MCLMaximum Contaminant Level Violation, AverageStage 1 Disinfectants and Disinfection Byproducts RuleTTHM805Returned to Compliance01-JAN-200531-MAR-2005Yes
MCLMaximum Contaminant Level Violation, AverageStage 1 Disinfectants and Disinfection Byproducts RuleTotal Haloacetic Acids (HAA5)705Returned to Compliance01-JAN-200531-MAR-2005Yes
MCLMaximum Contaminant Level Violation, AverageStage 1 Disinfectants and Disinfection Byproducts RuleTTHM105Returned to Compliance01-OCT-200431-DEC-2004Yes
MCLMaximum Contaminant Level Violation, AverageStage 1 Disinfectants and Disinfection Byproducts RuleTotal Haloacetic Acids (HAA5)205Returned to Compliance01-OCT-200431-DEC-2004Yes
MCLMaximum Contaminant Level Violation, AverageStage 1 Disinfectants and Disinfection Byproducts RuleTTHM304Returned to Compliance01-JUL-200430-SEP-2004Yes
MCLMaximum Contaminant Level Violation, AverageStage 1 Disinfectants and Disinfection Byproducts RuleTotal Haloacetic Acids (HAA5)404Returned to Compliance01-JUL-200430-SEP-2004Yes
MCLMaximum Contaminant Level Violation, AverageSynthetic Organic ChemicalsAtrazine980009579Returned to Compliance01-JAN-199831-MAR-1998Yes
  • 1 - 9 of 9

Enforcement Actions


Enforcement Actions

Latest Enforcement IDAssociated To Violation IDEnforcement Action Type CodeEnforcement Action DescriptionEnforcement DateOriginator DescriptionEnforcement Comment
3006105SOXState Compliance achieved22-FEB-2006State -
3006205SOXState Compliance achieved22-FEB-2006State -
3006304SOXState Compliance achieved22-FEB-2006State -
3006404SOXState Compliance achieved22-FEB-2006State -
3006980009579SOXState Compliance achieved22-FEB-2006State -
3006605SOXState Compliance achieved22-FEB-2006State -
3006705SOXState Compliance achieved22-FEB-2006State -
3306805SOXState Compliance achieved22-FEB-2006State -
3206505SOXState Compliance achieved22-FEB-2006State -
  • 1 - 9 of 9

PWS Facilities


All Facilities

Facility NameFacility IDIs SourceFacility Type DescriptionWater Type DescriptionAvailability DescriptionFacility Activity Status
SW FROM AQUILLA WSD35423YesConsecutive ConnectionSurface waterPermanentActive
4 - OAK SPRINGS / 165 WILD PLUM LN18088YesWell Ground waterPermanentActive
5 - SPIRES / 696 HCR 122118083YesWell Ground waterPermanentActive
1 - EUBANK / 1302 HCR 212417977YesWell Ground waterPermanentActive
2 - CLYMER / 510 HCR 124017976YesWell Ground waterPermanentActive
3 - ROGERS / 2365 S HWY 2217962YesWell Ground waterPermanentActive
6 - FARQUHAR / 266 FM 1534113012YesWell Ground waterPermanentActive
DISTRIBUTION SYSTEM42510NoDistribution System/Zone - - Active
PLANT 1 / EUBANK - 500 GPM - SP122481NoPump Facility - - Active
PLANT 2 / CLYMER - 225 GPM - SP122483NoPump Facility - - Active
PLANT 3 / ROGERS - 400 GPM - SP122484NoPump Facility - - Active
PLANT 4 / OAK SPRINGS - 300 GPM - SP122485NoPump Facility - - Active
PLANT 1 / EUBANK - 500 GPM - SP76854NoPump Facility - - Active
PLANT 4 / OAK SPRINGS - 300 GPM - SP76855NoPump Facility - - Active
PLANT 3 / ROGERS - 400 GPM - SP76856NoPump Facility - - Active
PLANT 2 / CLYMER - 225 GPM - SP76857NoPump Facility - - Active
266 FM 1534, WHITNEY114260NoSampling Station - - Active
1302 CR 2124; WHITNEY137120NoSampling Station - - Active
510 CR 1240; WHITNEY137121NoSampling Station - - Active
2365 HWY 22; WHITNEY137122NoSampling Station - - Active
165 WILD PLUM LN; WHITNEY137123NoSampling Station - - Active
4095 HWY 22; HILLSBORO137124NoSampling Station - - Active
696 CR 1221; WHITNEY137125NoSampling Station - - Active
266 FM 1534; WHITNEY137126NoSampling Station - - Active
1302 CR 2124, WHITNEY54279NoSampling Station - - Active
510 CR 1240, WHITNEY54280NoSampling Station - - Active
165 WILD PLUM LN, WHITNEY54281NoSampling Station - - Active
2365 HWY 22, WHITNEY54282NoSampling Station - - Active
4095 HWY 22, HILLSBORO54283NoSampling Station - - Active
696 CR 1221, WHITNEY61594NoSampling Station - - Active
PLANT 7 / FARQUAR - 0.1 MG - EL122493NoStorage - - Active
PLANT 1 / EUBANK - 0.006 MG - HD122495NoStorage - - Active
PLANT 2 / CLYMER - 0.005 MG - HD122497NoStorage - - Active
PLANT 2 / CLYMER - 0.005 MG - HD122499NoStorage - - Active
PLANT 3 / ROGERS - 0.006 MG - HD122500NoStorage - - Active
PLANT 4 / OAK SPRINGS - 0.004 MG - HD122501NoStorage - - Active
PLANT 4 / OAK SPRINGS - 0.004 MG - HD122502NoStorage - - Active
PLANT 6 / SPIRES - 0.183 MG - ST94513NoStorage - - Active
PLANT 5 / PEORIA - 0.31 MG - ST94514NoStorage - - Active
PLANT 4 / OAK SPRINGS - 0.06 MG - GR94515NoStorage - - Active
PLANT 3 / ROGERS - 0.1 MG - GR94516NoStorage - - Active
PLANT 2 / CLYMER - 0.03 MG - GR94517NoStorage - - Active
PLANT 2 / CLYMER - 0.03 MG - GR94518NoStorage - - Active
PLANT 2 / CLYMER - 0.06 MG - GR94519NoStorage - - Active
PLANT 1 / EUBANK - 0.1 MG - GR94520NoStorage - - Active
PLANT 7 - FARQUHAR / 266 FM 1534114261NoTreatment Plant - - Active
PLANT 2 - CLYMER / 510 HCR 2124 LOOP2922NoTreatment Plant - - Active
PLANT 1 - EUBANKS / 1302 HCR 2124 LOOP3487NoTreatment Plant - - Active
PLANT 4 - OAK SPRINGS / 165 WILD PLUM LN5320NoTreatment Plant - - Active
PLANT 5 - PEORIA / 133 HCR 131363134NoTreatment Plant - - Active
  • 1 - 50 of 52

PWS Treatment Processes


Treatment Processes

Facility NameFacility IDTreatment ProcessTreatment Objective
PLANT 7 - FARQUHAR / 266 FM 1534114261Gaseous Chlorination, PreDisinfection
PLANT 2 - CLYMER / 510 HCR 2124 LOOP2922Gaseous Chlorination, PreDisinfection
PLANT 1 - EUBANKS / 1302 HCR 2124 LOOP3487Gaseous Chlorination, PreDisinfection
PLANT 4 - OAK SPRINGS / 165 WILD PLUM LN5320Gaseous Chlorination, PreDisinfection
PLANT 5 - PEORIA / 133 HCR 131363134ChloraminesDisinfection
PLANT 5 - PEORIA / 133 HCR 131363134Gaseous Chlorination, PreDisinfection
PLANT 3 - ROGERS / 2365 S HWY 229574Gaseous Chlorination, PreDisinfection
PLANT 6 - SPIRE / 696 HCR 12219901Gaseous Chlorination, PreDisinfection
  • 1 - 8 of 8

For more information on a Water System:
Ask the operators of your water system, contact your primacy agency or file a Freedom of Information Act (FOIA) request.
Drinking water in general: Find out more about your drinking water web site or call the Safe Drinking Water Hotline (1-800-426-4791). EPA has also prepared a table about various regulated drinking water contaminants.
Tools for accessing EPA drinking water data: Safe Drinking Water Information System (SDWIS) Federal Reporting Services and Drinking Water Performance and Results Report.
Research Data: As well as monitoring the levels of drinking water contaminants for which EPA has set standards, EPA, states, and water systems also carry out studies of contaminants that may need to be regulated in the future. For more information about these contaminants, please see the National Contaminant Occurrence Database.