U.S. flag

An official website of the United States government

Safe Drinking Water Information System (SDWIS) Federal Reporting Services

Your Drinking Water Query results from SDWIS Fed Reporting Services

PWS IDTX0980004
PWS NameGRUVER MUNICIPAL WATER SYSTEM
PWS TypeCommunity water system
Owner TypeLocal government
Primary SourceGround water
Primacy TypeState
Is Wholesaler?No
Population Served1130
County ServedHansford

Note


The tables below list all violations that the state reported to EPA for this water system. Health-based violations are listed first, followed by treatment technique, MRDL, monitoring, reporting, and other violations.

Health-based Violations of maximum contaminant levels (MCLs) or maximum residual disinfectant levels (MRDLs), which specify the highest concentrations of contaminants or disinfectants, respectively, allowed in drinking water; or of treatment technique (TT) rules, which specify required processes intended to reduce the amounts of contaminants in drinking water. MCLs, MRDLs, and treatment technique rules are all health-based drinking water standards.
Maximum Contaminant Level or MCL The highest level of a contaminant that is allowed in drinking water. MCLs are set as close to the MCLGs as feasible using the best available treatment technology.
Treatment Technique A required process intended to reduce the level of a contaminant in drinking water.
Maximum residual disinfectant level or MRDL The highest level of a disinfectant allowed in drinking water. There is convincing evidence that addition of a disinfectant is necessary for control of microbial contaminants.
Monitoring & reporting Failure to conduct regular monitoring of drinking water quality, as required by SDWA, or to submit monitoring results in a timely fashion to the primacy agency or EPA.
Public notification & other Failure to provide notification to the public as required by the Violations of Public Notification Rule and the Consumer Confidence Report Rule, and violations of other requirements such as those violations related to variances and exemptions.

PWS Violation


Violations

Violation Category CodeViolation Type DescriptionRule NameContaminant NameViolation IDCompliance Status DescriptionCompliance Period Begin DateCompliance Period End DateIs Health Based Ind
MRLead Consumer NoticeLead and Copper RuleLead and Copper Rule27Returned to Compliance30-DEC-2016 - No
MRLead Consumer NoticeLead and Copper RuleLead and Copper Rule22Returned to Compliance30-DEC-2013 - No
MRMonitoring and Reporting (DBP)Stage 1 Disinfectants and Disinfection Byproducts RuleChlorine21Returned to Compliance01-APR-201330-JUN-2013No
MCLMaximum Contaminant Level Violation, Monthly (TCR)Total Coliform RuleColiform (TCR)6Returned to Compliance01-NOV-201230-NOV-2012Yes
MRMonitoring, Source Water (GWR)Ground Water RuleE. COLI11Returned to Compliance01-NOV-2012 - No
MCLMaximum Contaminant Level Violation, Monthly (TCR)Total Coliform RuleColiform (TCR)5Returned to Compliance01-OCT-201231-OCT-2012Yes
OtherPublic Notification Violation for NPDWR ViolationPublic Notice Rule and Revised PN RulePublic Notice10Returned to Compliance01-SEP-2012 - No
MCLMaximum Contaminant Level Violation, Monthly (TCR)Total Coliform RuleColiform (TCR)4Returned to Compliance01-SEP-201230-SEP-2012Yes
MRMonitoring, Routine Major (TCR)Total Coliform RuleColiform (TCR)3Returned to Compliance01-JUN-201230-JUN-2012No
OtherPublic Notification Violation for NPDWR ViolationPublic Notice Rule and Revised PN RulePublic Notice2Returned to Compliance10-JUN-2011 - No
MRMonitoring, Routine Minor (TCR)Total Coliform RuleColiform (TCR)1Returned to Compliance01-FEB-201128-FEB-2011No
MRFollow-up Or Routine LCR Tap M/RLead and Copper RuleLead and Copper Rule20Returned to Compliance01-OCT-2010 - No
MCLMaximum Contaminant Level Violation, AverageInorganic ChemicalsFluoride87586Known17-AUG-198416-AUG-1985Yes
MCLMaximum Contaminant Level Violation, AverageInorganic ChemicalsFluoride1233282Known26-MAR-198225-APR-1982Yes
MCLMaximum Contaminant Level Violation, AverageInorganic ChemicalsFluoride408885Known26-MAR-198225-MAR-1983Yes
  • 1 - 15 of 15

Enforcement Actions


Enforcement Actions

Latest Enforcement IDAssociated To Violation IDEnforcement Action Type CodeEnforcement Action DescriptionEnforcement DateOriginator DescriptionEnforcement Comment
4622SOXState Compliance achieved08-MAR-2017State -
4527SOXState Compliance achieved08-MAR-2017State -
386SOXState Compliance achieved11-MAY-2015State -
375SOXState Compliance achieved11-MAY-2015State -
364SOXState Compliance achieved11-MAY-2015State -
393SOXState Compliance achieved11-MAY-2015State -
3521SOXState Compliance achieved17-JUL-2014StateSubmitted first quarter of 2014 DLQOR
3120SOXState Compliance achieved14-NOV-2013State -
3011SOXState Compliance achieved30-MAY-2013State -
2410SIAState Violation/Reminder Notice29-JAN-2013State -
101SOXState Compliance achieved01-SEP-2011State -
32SOXState Compliance achieved21-JUL-2011State -
  • 1 - 12 of 12

PWS Facilities


All Facilities

Facility NameFacility IDIs SourceFacility Type DescriptionWater Type DescriptionAvailability DescriptionFacility Activity Status
2 - NORTH PS (100 BLK OF CATOR)17147YesWell Ground waterPermanentActive
1 - SOUTH PS (4TH / CATOR)17167YesWell Ground waterPermanentActive
3 - 7TH / CATOR17148YesWell Ground waterPermanentActive
DISTRIBUTION SYSTEM40848NoDistribution System/Zone - - Active
NORTH PS - 400 GPM - SP122799NoPump Facility - - Active
SOUTH PS - 200 GPM - SP122800NoPump Facility - - Active
CATOR ST PS - 750 GPM - SP122801NoPump Facility - - Active
NORTH PS - 250 GPM - SP122802NoPump Facility - - Active
CATOR ST PS - 750 GPM - SP122804NoPump Facility - - Active
CATOR ST PS - 750 GPM - SP122806NoPump Facility - - Active
SOUTH PS - 600 GPM - SP122803NoPump Facility - - Inactive
SOUTH PS - 750 GPM - SP122805NoPump Facility - - Inactive
4TH ST AND CATOR AVE; GRUVER135417NoSampling Station - - Active
1ST ST AND CATOR AVE; GRUVER135418NoSampling Station - - Active
4TH ST AND CATOR AVE, GRUVER51590NoSampling Station - - Active
1ST ST AND CATOR AVE, GRUVER51591NoSampling Station - - Active
CATOR STREET PS - 0.25 MG - ST112573NoStorage - - Active
CATOR STREET PS - 0.25 MG - GR112575NoStorage - - Active
100 BLK OF CATOR NORTH PS - 0.1 MG - GR112578NoStorage - - Active
4TH AND CATOR SOUTH PS - 0.1 MG - GR112580NoStorage - - Active
4TH & CATOR SOUTH PS - 0.05 MG - EL112574NoStorage - - Inactive
PLANT - NORTH PS - 1ST / CATOR5241NoTreatment Plant - - Active
PLANT - SOUTH PS - 4TH / CATOR9858NoTreatment Plant - - Active
  • 1 - 23 of 23

PWS Treatment Processes


Treatment Processes

Facility NameFacility IDTreatment ProcessTreatment Objective
PLANT - NORTH PS - 1ST / CATOR5241Gaseous Chlorination, PreDisinfection
PLANT - SOUTH PS - 4TH / CATOR9858Gaseous Chlorination, PreDisinfection
  • 1 - 2 of 2

For more information on a Water System:
Ask the operators of your water system, contact your primacy agency or file a Freedom of Information Act (FOIA) request.
Drinking water in general: Find out more about your drinking water web site or call the Safe Drinking Water Hotline (1-800-426-4791). EPA has also prepared a table about various regulated drinking water contaminants.
Tools for accessing EPA drinking water data: Safe Drinking Water Information System (SDWIS) Federal Reporting Services and Drinking Water Performance and Results Report.
Research Data: As well as monitoring the levels of drinking water contaminants for which EPA has set standards, EPA, states, and water systems also carry out studies of contaminants that may need to be regulated in the future. For more information about these contaminants, please see the National Contaminant Occurrence Database.