PWS NameCITY OF FRIENDSWOOD
PWS TypeCommunity water system
Owner TypeLocal government
Primary SourceSurface water purchased
Primacy TypeState
Is Wholesaler?No
Population Served43190
County ServedGalveston

Note


The tables below list all violations that the state reported to EPA for this water system. Health-based violations are listed first, followed by treatment technique, MRDL, monitoring, reporting, and other violations.

Health-based Violations of maximum contaminant levels (MCLs) or maximum residual disinfectant levels (MRDLs), which specify the highest concentrations of contaminants or disinfectants, respectively, allowed in drinking water; or of treatment technique (TT) rules, which specify required processes intended to reduce the amounts of contaminants in drinking water. MCLs, MRDLs, and treatment technique rules are all health-based drinking water standards.
Maximum Contaminant Level or MCL The highest level of a contaminant that is allowed in drinking water. MCLs are set as close to the MCLGs as feasible using the best available treatment technology.
Treatment Technique A required process intended to reduce the level of a contaminant in drinking water.
Maximum residual disinfectant level or MRDL The highest level of a disinfectant allowed in drinking water. There is convincing evidence that addition of a disinfectant is necessary for control of microbial contaminants.
Monitoring & reporting Failure to conduct regular monitoring of drinking water quality, as required by SDWA, or to submit monitoring results in a timely fashion to the primacy agency or EPA.
Public notification & other Failure to provide notification to the public as required by the Violations of Public Notification Rule and the Consumer Confidence Report Rule, and violations of other requirements such as those violations related to variances and exemptions.

PWS Violation


Violations

Violation Category CodeViolation Type DescriptionRule NameContaminant NameViolation IDCompliance Status DescriptionCompliance Period Begin DateCompliance Period End DateIs Health Based Ind
MRLead Consumer NoticeLead and Copper RuleLead and Copper Rule56Returned to Compliance30-DEC-2013 - No
OtherNotification, PublicTotal Coliform RuleColiform (TCR)4041693Known01-SEP-199330-SEP-1993No
MRMonitoring, Routine Minor (TCR)Total Coliform RuleColiform (TCR)4041593Known01-SEP-199330-SEP-1993No
  • 1 - 3 of 3

Enforcement Actions


Enforcement Actions

PWS Facilities


All Facilities

Facility NameFacility IDIs SourceFacility Type DescriptionWater Type DescriptionAvailability DescriptionFacility Activity Status
SW FROM CITY OF HOUSTON34868YesConsecutive ConnectionSurface waterPermanentActive
4 - 500 W CASTLE HARBOR / PLANT 415868YesWell Ground waterSeasonalActive
6 - 5006 PENNY STONE / PLANT 615854YesWell Ground waterSeasonalActive
2 - 809 MERRIWOOD / PLANT 215850YesWell Ground waterSeasonalActive
3 - 605 STONELEDGE DR / PLANT 315848YesWell Ground waterSeasonalActive
7 - 3635 FRIENDSWOOD LINK / PLANT 715844YesWell Ground waterSeasonalActive
5 - 1100 COLT RD / PLANT 515842YesWell Ground waterSeasonalActive
8 - FM 528 / MOORE / PLUGGED15874YesWell Ground waterPermanentInactive
TOWER ESTATES / PLUGGED15846YesWell Ground waterPermanentInactive
SW FROM CITY OF HOUSTON34869YesConsecutive ConnectionSurface waterPermanentActive
DISTRIBUTION SYSTEM40394NoDistribution System/Zone - - Active
4428 FM 2351 - 4000 GPM - SP124140NoPump Facility - - Active
809 MERRIEWOOD DR - 650 GPM - SP82861NoPump Facility - - Active
809 MERRIEWOOD DR - 650 GPM - SP82862NoPump Facility - - Active
605 STONELEDGE DR - 650 GPM - SP82863NoPump Facility - - Active
605 STONELEDGE DR - 650 GPM - SP82864NoPump Facility - - Active
500 W CASTLE HARBOUR DR - 1000 GPM - SP82865NoPump Facility - - Active
500 W CASTLE HARBOUR DR - 1000 GPM - SP82866NoPump Facility - - Active
1100 COLT AVE - 875 GPM - SP82869NoPump Facility - - Active
1100 COLT AVE - 875 GPM - SP82870NoPump Facility - - Active
1100 COLT AVE - 875 GPM - SP82871NoPump Facility - - Active
5006 PENNYSTONE WAY - 700 GPM - SP82872NoPump Facility - - Active
5006 PENNYSTONE WAY - 700 GPM - SP82873NoPump Facility - - Active
3635 FRIENDSWOOD LINK RD - 750 GPM - SP82874NoPump Facility - - Active
3635 FRIENDSWOOD LINK RD - 750 GPM - SP82875NoPump Facility - - Active
3635 FRIENDSWOOD LINK RD - 750 GPM - SP82876NoPump Facility - - Active
BLACK HAWK - 2000 GPM - SP82877NoPump Facility - - Active
BLACK HAWK - 2000 GPM - SP82878NoPump Facility - - Active
BLACK HAWK - 2000 GPM - SP82879NoPump Facility - - Active
BLACK HAWK - 2000 GPM - SP82880NoPump Facility - - Active
4428 FM 2351 - 4000 GPM - SP82881NoPump Facility - - Active
4428 FM 2351 - 4000 GPM - SP82882NoPump Facility - - Active
4428 FM 2351 - 4000 GPM - SP82883NoPump Facility - - Active
5006 PENNYSTONE WAY - 700 GPM - SP83175NoPump Facility - - Active
3635 FRIENDSWOOD LINK RD - 600 GPM - SP83176NoPump Facility - - Active
17158 BLACKHAWK BLVD; FRIENDSWOOD135044NoSampling Station - - Active
605 STONELEDGE135045NoSampling Station - - Active
500 W CASTLE HARBOR135046NoSampling Station - - Active
702 GREENBRIAR DR; FRIENDSWOOD135047NoSampling Station - - Active
5006 PENNYSTONE WAY; FRIENDSWOOD135048NoSampling Station - - Active
4428 FM 2351; FRIENDSWOOD135049NoSampling Station - - Active
17158 BLACKHAWK BLVD, FRIENDSWOOD51023NoSampling Station - - Active
5006 PENNYSTONE WAY, FRIENDSWOOD51025NoSampling Station - - Active
605 STONELEDGE51026NoSampling Station - - Active
500 W CASTLE HARBOR51028NoSampling Station - - Active
702 GREENBRIAR DR, FRIENDSWOOD51029NoSampling Station - - Active
4428 FM 2351, FRIENDSWOOD62354NoSampling Station - - Active
809 MERRIWOOD51024NoSampling Station - - Inactive
3635 FRIENDSWOOD LINK51027NoSampling Station - - Inactive
605 STONELEDGE - 0.5 MG - GR102081NoStorage - - Active
  • 1 - 50 of 71

PWS Treatment Processes


Treatment Processes

Facility NameFacility IDTreatment ProcessTreatment Objective
PLANT - MERRIWOOD1034ChloraminesDisinfection
PLANT - MERRIWOOD1034Inhibitor, PolyphosphateCorrosion control
PLANT - MERRIWOOD1034Gaseous Chlorination, PreDisinfection
PLANT - FM 528111156ChloraminesDisinfection
PLANT - FM 528111156Gaseous Chlorination, PreDisinfection
PLANT - FM 528111156Inhibitor, PolyphosphateCorrosion control
PLANT - WEST CASTLE HARBOR11386ChloraminesDisinfection
PLANT - WEST CASTLE HARBOR11386Inhibitor, PolyphosphateCorrosion control
PLANT - WEST CASTLE HARBOR11386Gaseous Chlorination, PreDisinfection
PLANT - BLACK HAWK1477Inhibitor, PolyphosphateCorrosion control
PLANT - BLACK HAWK1477ChloraminesDisinfection
PLANT - BLACK HAWK1477Gaseous Chlorination, PreDisinfection
PLANT - COLT RD2945Gaseous Chlorination, PreDisinfection
PLANT - COLT RD2945ChloraminesDisinfection
PLANT - COLT RD2945Inhibitor, PolyphosphateCorrosion control
PLANT - FRIENDSWOOD LINK3698Gaseous Chlorination, PreDisinfection
PLANT - FRIENDSWOOD LINK3698ChloraminesDisinfection
PLANT - FRIENDSWOOD LINK3698Inhibitor, PolyphosphateCorrosion control
PLANT - FM 23514975Gaseous Chlorination, PreDisinfection
PLANT - FM 23514975ChloraminesDisinfection
PLANT - PENNY STONE5532Gaseous Chlorination, PreDisinfection
PLANT - PENNY STONE5532ChloraminesDisinfection
PLANT - PENNY STONE5532Inhibitor, PolyphosphateCorrosion control
PLANT - STONELEDGE DR9977Inhibitor, PolyphosphateCorrosion control
PLANT - STONELEDGE DR9977ChloraminesDisinfection
PLANT - STONELEDGE DR9977Gaseous Chlorination, PreDisinfection
  • 1 - 26 of 26

For more information on a Water System:
Ask the operators of your water system, contact your primacy agency or file a Freedom of Information Act (FOIA) request.
Drinking water in general: Find out more about your drinking water web site or call the Safe Drinking Water Hotline (1-800-426-4791). EPA has also prepared a table about various regulated drinking water contaminants.
Tools for accessing EPA drinking water data: Safe Drinking Water Information System (SDWIS) Federal Reporting Services and Drinking Water Performance and Results Report.
Research Data: As well as monitoring the levels of drinking water contaminants for which EPA has set standards, EPA, states, and water systems also carry out studies of contaminants that may need to be regulated in the future. For more information about these contaminants, please see the National Contaminant Occurrence Database.