U.S. flag

An official website of the United States government

Safe Drinking Water Information System (SDWIS) Federal Reporting Services

Your Drinking Water Query results from SDWIS Fed Reporting Services

PWS IDTX0470015
PWS NameUPPER LEON RIVER MWD
PWS TypeCommunity water system
Owner TypeLocal government
Primary SourceSurface water
Primacy TypeState
Is Wholesaler?Yes
Population Served2919
County ServedComanche

Note


The tables below list all violations that the state reported to EPA for this water system. Health-based violations are listed first, followed by treatment technique, MRDL, monitoring, reporting, and other violations.

Health-based Violations of maximum contaminant levels (MCLs) or maximum residual disinfectant levels (MRDLs), which specify the highest concentrations of contaminants or disinfectants, respectively, allowed in drinking water; or of treatment technique (TT) rules, which specify required processes intended to reduce the amounts of contaminants in drinking water. MCLs, MRDLs, and treatment technique rules are all health-based drinking water standards.
Maximum Contaminant Level or MCL The highest level of a contaminant that is allowed in drinking water. MCLs are set as close to the MCLGs as feasible using the best available treatment technology.
Treatment Technique A required process intended to reduce the level of a contaminant in drinking water.
Maximum residual disinfectant level or MRDL The highest level of a disinfectant allowed in drinking water. There is convincing evidence that addition of a disinfectant is necessary for control of microbial contaminants.
Monitoring & reporting Failure to conduct regular monitoring of drinking water quality, as required by SDWA, or to submit monitoring results in a timely fashion to the primacy agency or EPA.
Public notification & other Failure to provide notification to the public as required by the Violations of Public Notification Rule and the Consumer Confidence Report Rule, and violations of other requirements such as those violations related to variances and exemptions.

PWS Violation


Violations

Violation Category CodeViolation Type DescriptionRule NameContaminant NameViolation IDCompliance Status DescriptionCompliance Period Begin DateCompliance Period End DateIs Health Based Ind
OtherPublic Notification Violation for NPDWR ViolationPublic Notice Rule and Revised PN RulePublic Notice772Returned to Compliance05-JAN-2024 - No
MCLMaximum Contaminant Level Violation, AverageStage 2 Disinfectants and Disinfection Byproducts RuleTTHM774Returned to Compliance01-JAN-202431-MAR-2024Yes
MCLMaximum Contaminant Level Violation, AverageStage 2 Disinfectants and Disinfection Byproducts RuleTTHM767Returned to Compliance01-OCT-202331-DEC-2023Yes
OtherPublic Notification Violation for NPDWR ViolationPublic Notice Rule and Revised PN RulePublic Notice758Returned to Compliance31-MAR-2021 - No
OtherPublic Notification Violation without NPDWR ViolationPublic Notice Rule and Revised PN RulePublic Notice757Returned to Compliance22-MAR-2021 - No
OtherPublic Notification Violation without NPDWR ViolationPublic Notice Rule and Revised PN RulePublic Notice756Returned to Compliance17-MAR-2021 - No
TTMonthly Turbidity Exceed (Enhanced SWTR)Interim and Long Term 1 Enhanced Surface Water Treatment RuleInterim Enhanced Surface Water Treatment Rule755Returned to Compliance01-FEB-202128-FEB-2021Yes
MRWater Quality Parameter M/RLead and Copper RuleLead and Copper Rule759Returned to Compliance01-JAN-202130-JUN-2021No
MRMonitoring, Turbidity (Enhanced SWTR)Interim and Long Term 1 Enhanced Surface Water Treatment RuleInterim Enhanced Surface Water Treatment Rule752Returned to Compliance01-SEP-202030-SEP-2020No
MRMonitoring, Turbidity (Enhanced SWTR)Interim and Long Term 1 Enhanced Surface Water Treatment RuleInterim Enhanced Surface Water Treatment Rule750Returned to Compliance01-SEP-202030-SEP-2020No
MRMonitoring, Turbidity (Enhanced SWTR)Interim and Long Term 1 Enhanced Surface Water Treatment RuleInterim Enhanced Surface Water Treatment Rule746Returned to Compliance01-AUG-202031-AUG-2020No
MRMonitoring, Turbidity (Enhanced SWTR)Interim and Long Term 1 Enhanced Surface Water Treatment RuleInterim Enhanced Surface Water Treatment Rule748Returned to Compliance01-AUG-202031-AUG-2020No
OtherPublic Notification Violation for NPDWR ViolationPublic Notice Rule and Revised PN RulePublic Notice739Returned to Compliance08-FEB-2016 - No
MRFollow-up Or Routine LCR Tap M/RLead and Copper RuleLead and Copper Rule738Returned to Compliance01-OCT-2015 - No
MCLMaximum Contaminant Level Violation, AverageStage 1 Disinfectants and Disinfection Byproducts RuleTTHM716Returned to Compliance01-JAN-201231-MAR-2012Yes
MCLMaximum Contaminant Level Violation, AverageStage 1 Disinfectants and Disinfection Byproducts RuleTTHM714Returned to Compliance01-OCT-201131-DEC-2011Yes
MCLMaximum Contaminant Level Violation, AverageStage 1 Disinfectants and Disinfection Byproducts RuleTTHM715Returned to Compliance01-JUL-201130-SEP-2011Yes
MCLMaximum Contaminant Level Violation, AverageStage 1 Disinfectants and Disinfection Byproducts RuleTTHM713Returned to Compliance01-APR-201130-JUN-2011Yes
MCLMaximum Contaminant Level Violation, AverageStage 1 Disinfectants and Disinfection Byproducts RuleTTHM712Returned to Compliance01-JAN-201131-MAR-2011Yes
MCLMaximum Contaminant Level Violation, AverageStage 1 Disinfectants and Disinfection Byproducts RuleTTHM711Returned to Compliance01-OCT-201031-DEC-2010Yes
MRMonitoring, Turbidity (Enhanced SWTR)Interim and Long Term 1 Enhanced Surface Water Treatment RuleInterim Enhanced Surface Water Treatment Rule406Returned to Compliance01-JUL-200631-JUL-2006No
MRMonitoring, Repeat Minor (TCR)Total Coliform RuleColiform (TCR)191Known01-MAR-199131-MAR-1991No
  • 1 - 22 of 22

Enforcement Actions


Enforcement Actions

Latest Enforcement IDAssociated To Violation IDEnforcement Action Type CodeEnforcement Action DescriptionEnforcement DateOriginator DescriptionEnforcement Comment
706774SOXState Compliance achieved09-MAY-2024State20240509 XGONZALE; VIOLS SOX'D BASED ON DBP2-01 AND DBP2-02 2Q2024 TTHM LRAA
706767SOXState Compliance achieved09-MAY-2024State20240509 XGONZALE; VIOLS SOX'D BASED ON DBP2-01 AND DBP2-02 2Q2024 TTHM LRAA
697772SOXState Compliance achieved24-JAN-2024State -
687759SOXState Compliance achieved18-JAN-2022State6M2 2021 SUCCESSFUL WQP MP -MROSS 1/18/22
672755SIFState Public Notification received01-JUN-2021State -
675756SOXState Compliance achieved27-MAY-2021State -
676757SOXState Compliance achieved27-MAY-2021State -
677758SOXState Compliance achieved27-MAY-2021State -
662752SIFState Public Notification received22-APR-2021State -
661750SIFState Public Notification received22-APR-2021State -
657748SIFState Public Notification received22-APR-2021State -
658746SIFState Public Notification received22-APR-2021State -
629738SOXState Compliance achieved27-SEP-2016State -
627739SOXState Compliance achieved24-JUN-2016State -
622715SOXState Compliance achieved03-SEP-2013State09/03/2013;KSAMPLES; DBP COMPLIANCE REVIEW
622712SOXState Compliance achieved03-SEP-2013State09/03/2013;KSAMPLES; DBP COMPLIANCE REVIEW
622711SOXState Compliance achieved03-SEP-2013State09/03/2013;KSAMPLES; DBP COMPLIANCE REVIEW
622714SOXState Compliance achieved03-SEP-2013State09/03/2013;KSAMPLES; DBP COMPLIANCE REVIEW
622716SOXState Compliance achieved03-SEP-2013State09/03/2013;KSAMPLES; DBP COMPLIANCE REVIEW
622713SOXState Compliance achieved03-SEP-2013State09/03/2013;KSAMPLES; DBP COMPLIANCE REVIEW
611406SOXState Compliance achieved01-SEP-2006State -
191191SFJState Formal Notice of Violation issued20-APR-1991State -
  • 1 - 22 of 22

PWS Facilities


All Facilities

Facility NameFacility IDIs SourceFacility Type DescriptionWater Type DescriptionAvailability DescriptionFacility Activity Status
INTAKE 1 - LK PROCTOR33464YesIntakeSurface waterPermanentActive
RAW-TAP117457NoCommon Headers - - Active
RAW-TAP151483NoCommon Headers - - Active
DISTRIBUTION SYSTEM39277NoDistribution System/Zone - - Active
DUBLIN PS - 750 GPM - SP130689NoPump Facility - - Active
DUBLIN PS - 750 GPM - SP130691NoPump Facility - - Active
DUBLIN PS - 750 GPM - SP130692NoPump Facility - - Active
HIGH POINT PS - 250 GPM - SP159914NoPump Facility - - Active
HIGH POINT PS - 250 GPM - SP159916NoPump Facility - - Active
COUNTY LINE PS DUBLIN - 990 GPM - SP159918NoPump Facility - - Active
COUNTY LINE PS DUBLIN - 990 GPM - SP159920NoPump Facility - - Active
COUNTY LINE PS DUBLIN - 990 GPM - SP159922NoPump Facility - - Active
COUNTY LINE PS DE LEON - 510 GPM - SP159924NoPump Facility - - Active
COUNTY LINE PS DE LEON - 510 GPM - SP159926NoPump Facility - - Active
COUNTY LINE PS DE LEON - 510 GPM - SP159928NoPump Facility - - Active
INTERMEDIATE PS - 500 GPM - SP159930NoPump Facility - - Active
WTP COUNTY LINE - 1530 GPM - SP159933NoPump Facility - - Active
WTP COUNTY LINE - 1530 GPM - SP159935NoPump Facility - - Active
WTP COUNTY LINE - 1530 GPM - SP159937NoPump Facility - - Active
WTP COMANCHE LINE - 900 GPM - SP159939NoPump Facility - - Active
WTP COMANCHE LINE - 900 GPM - SP159941NoPump Facility - - Active
WTP COMANCHE LINE - 900 GPM - SP159943NoPump Facility - - Active
GORMAN PS - 600 GPM - SP82557NoPump Facility - - Active
GORMAN PS - 360 GPM - SP82558NoPump Facility - - Active
GORMAN PS - 360 GPM - SP82559NoPump Facility - - Active
INTERMEDIATE PS - 350 GPM - SP82570NoPump Facility - - Active
WTP HAMILTON LINE - 1200 GPM - SP82572NoPump Facility - - Active
WTP HAMILTON LINE - 1200 GPM - SP82573NoPump Facility - - Active
WTP HAMILTON LINE - 1200 GPM - SP82574NoPump Facility - - Active
HAMILTON 4 PS - 1200 GPM - SP82581NoPump Facility - - Active
HAMILTON 4 PS - 1200 GPM - SP82582NoPump Facility - - Active
HAMILTON 4 PS - 1200 GPM - SP82583NoPump Facility - - Active
HAMILTON 3 PS - 1200 GPM - SP82584NoPump Facility - - Active
HAMILTON 3 PS - 1200 GPM - SP82585NoPump Facility - - Active
HAMILTON 3 PS - 1200 GPM - SP82586NoPump Facility - - Active
BUFFALO SPRINGS PS - 150 GPM - SP82560NoPump Facility - - Inactive
BUFFALO SPRINGS PS - 150 GPM - SP82561NoPump Facility - - Inactive
FOLEY HIGH POINT PS - 150 GPM - SP82562NoPump Facility - - Inactive
FOLEY HIGH POINT PS - 150 GPM - SP82563NoPump Facility - - Inactive
COUNTY LINE DUBLIN PS - 360 GPM - SP82564NoPump Facility - - Inactive
COUNTY LINE DUBLIN PS - 700 GPM - SP82565NoPump Facility - - Inactive
COUNTY LINE DUBLIN PS - 1400 GPM - SP82566NoPump Facility - - Inactive
COUNTY LINE DE LEON PS - 350 GPM - SP82567NoPump Facility - - Inactive
COUNTY LINE DE LEON PS - 1050 GPM - SP82568NoPump Facility - - Inactive
COUNTY LINE DE LEON PS - 1400 GPM - SP82569NoPump Facility - - Inactive
INTERMEDIATE PS - 450 GPM - SP82571NoPump Facility - - Inactive
WTP COUNTY LINE - 700 GPM - SP82575NoPump Facility - - Inactive
WTP COUNTY LINE - 1750 GPM - SP82576NoPump Facility - - Inactive
WTP COUNTY LINE - 2800 GPM - SP82577NoPump Facility - - Inactive
WTP COMANCHE LINE - 350 GPM - SP82578NoPump Facility - - Inactive
  • 1 - 50 of 69

PWS Treatment Processes


Treatment Processes

Facility NameFacility IDTreatment ProcessTreatment Objective
MEMBRANE PLANT - LK PROCTOR148452Chlorine DioxideDisinfection
MEMBRANE PLANT - LK PROCTOR148452InnovativeDisinfection
MEMBRANE PLANT - LK PROCTOR148452Gaseous Chlorination, PreDisinfection
MEMBRANE PLANT - LK PROCTOR148452InnovativeDisinfection
MEMBRANE PLANT - LK PROCTOR148452InnovativeDisinfection
MEMBRANE PLANT - LK PROCTOR148452InnovativeDisinfection
MEMBRANE PLANT - LK PROCTOR148452InnovativeParticulate removal
MEMBRANE PLANT - LK PROCTOR148452FlocculationParticulate removal
MEMBRANE PLANT - LK PROCTOR148452FlocculationParticulate removal
MEMBRANE PLANT - LK PROCTOR148452FlocculationParticulate removal
MEMBRANE PLANT - LK PROCTOR148452SedimentationParticulate removal
MEMBRANE PLANT - LK PROCTOR148452InnovativeParticulate removal
MEMBRANE PLANT - LK PROCTOR148452FilteredParticulate removal
MEMBRANE PLANT - LK PROCTOR148452InnovativeDisinfection
MEMBRANE PLANT - LK PROCTOR148452InnovativeDisinfection
MEMBRANE PLANT - LK PROCTOR148452InnovativeDisinfection
MEMBRANE PLANT - LK PROCTOR148452Gaseous Chlorination, PreDisinfection
MEMBRANE PLANT - LK PROCTOR148452Rapid MixParticulate removal
MEMBRANE PLANT - LK PROCTOR148452Rapid MixParticulate removal
MEMBRANE PLANT - LK PROCTOR148452InnovativeDisinfection
MEMBRANE PLANT - LK PROCTOR148452InnovativeDisinfection
MEMBRANE PLANT - LK PROCTOR148452Gaseous Chlorination, PostDisinfection
MEMBRANE PLANT - LK PROCTOR148452InnovativeDisinfection
MEMBRANE PLANT - LK PROCTOR148452InnovativeDisinfection
MEMBRANE PLANT - LK PROCTOR148452Gaseous Chlorination, PreDisinfection
SWTP CONVENTIONAL PLANT - LK PROCTOR8678InnovativeDisinfection
SWTP CONVENTIONAL PLANT - LK PROCTOR8678InnovativeDisinfection
SWTP CONVENTIONAL PLANT - LK PROCTOR8678InnovativeDisinfection
SWTP CONVENTIONAL PLANT - LK PROCTOR8678InnovativeDisinfection
SWTP CONVENTIONAL PLANT - LK PROCTOR8678CoagulationParticulate removal
SWTP CONVENTIONAL PLANT - LK PROCTOR8678CoagulationParticulate removal
SWTP CONVENTIONAL PLANT - LK PROCTOR8678InnovativeParticulate removal
SWTP CONVENTIONAL PLANT - LK PROCTOR8678CoagulationParticulate removal
SWTP CONVENTIONAL PLANT - LK PROCTOR8678PermanganateTaste / odor control
SWTP CONVENTIONAL PLANT - LK PROCTOR8678Rapid MixParticulate removal
SWTP CONVENTIONAL PLANT - LK PROCTOR8678InnovativeParticulate removal
SWTP CONVENTIONAL PLANT - LK PROCTOR8678Hypochlorination, PreDisinfection
SWTP CONVENTIONAL PLANT - LK PROCTOR8678InnovativeDisinfection
SWTP CONVENTIONAL PLANT - LK PROCTOR8678InnovativeParticulate removal
SWTP CONVENTIONAL PLANT - LK PROCTOR8678InnovativeDisinfection
SWTP CONVENTIONAL PLANT - LK PROCTOR8678Hypochlorination, PostDisinfection
SWTP CONVENTIONAL PLANT - LK PROCTOR8678InnovativeDisinfection
SWTP CONVENTIONAL PLANT - LK PROCTOR8678InnovativeDisinfection
SWTP CONVENTIONAL PLANT - LK PROCTOR8678InnovativeDisinfection
SWTP CONVENTIONAL PLANT - LK PROCTOR8678InnovativeDisinfection
SWTP CONVENTIONAL PLANT - LK PROCTOR8678InnovativeDisinfection
SWTP CONVENTIONAL PLANT - LK PROCTOR8678InnovativeDisinfection
SWTP CONVENTIONAL PLANT - LK PROCTOR8678InnovativeDisinfection
SWTP CONVENTIONAL PLANT - LK PROCTOR8678InnovativeDisinfection
SWTP CONVENTIONAL PLANT - LK PROCTOR8678InnovativeParticulate removal
  • 1 - 50 of 84

For more information on a Water System:
Ask the operators of your water system, contact your primacy agency or file a Freedom of Information Act (FOIA) request.
Drinking water in general: Find out more about your drinking water web site or call the Safe Drinking Water Hotline (1-800-426-4791). EPA has also prepared a table about various regulated drinking water contaminants.
Tools for accessing EPA drinking water data: Safe Drinking Water Information System (SDWIS) Federal Reporting Services and Drinking Water Performance and Results Report.
Research Data: As well as monitoring the levels of drinking water contaminants for which EPA has set standards, EPA, states, and water systems also carry out studies of contaminants that may need to be regulated in the future. For more information about these contaminants, please see the National Contaminant Occurrence Database.