Your Drinking Water Query results from SDWIS Fed Reporting Services

PWS IDTX0420001
PWS NameCITY OF COLEMAN
PWS TypeCommunity water system
Owner TypeLocal government
Primary SourceSurface water
Primacy TypeState
Is Wholesaler?Yes
Population Served4136
County ServedColeman

Note


The tables below list all violations that the state reported to EPA for this water system. Health-based violations are listed first, followed by treatment technique, MRDL, monitoring, reporting, and other violations.

Health-based Violations of maximum contaminant levels (MCLs) or maximum residual disinfectant levels (MRDLs), which specify the highest concentrations of contaminants or disinfectants, respectively, allowed in drinking water; or of treatment technique (TT) rules, which specify required processes intended to reduce the amounts of contaminants in drinking water. MCLs, MRDLs, and treatment technique rules are all health-based drinking water standards.
Maximum Contaminant Level or MCL The highest level of a contaminant that is allowed in drinking water. MCLs are set as close to the MCLGs as feasible using the best available treatment technology.
Treatment Technique A required process intended to reduce the level of a contaminant in drinking water.
Maximum residual disinfectant level or MRDL The highest level of a disinfectant allowed in drinking water. There is convincing evidence that addition of a disinfectant is necessary for control of microbial contaminants.
Monitoring & reporting Failure to conduct regular monitoring of drinking water quality, as required by SDWA, or to submit monitoring results in a timely fashion to the primacy agency or EPA.
Public notification & other Failure to provide notification to the public as required by the Violations of Public Notification Rule and the Consumer Confidence Report Rule, and violations of other requirements such as those violations related to variances and exemptions.

PWS Violation


Violations

Violation Category CodeViolation Type DescriptionRule NameContaminant NameViolation IDCompliance Status DescriptionCompliance Period Begin DateCompliance Period End DateIs Health Based Ind
MCLMaximum Contaminant Level Violation, AverageStage 2 Disinfectants and Disinfection Byproducts RuleTTHM1054Returned to Compliance01-JUL-201830-SEP-2018Yes
MCLMaximum Contaminant Level Violation, AverageStage 2 Disinfectants and Disinfection Byproducts RuleTTHM1052Returned to Compliance01-APR-201830-JUN-2018Yes
MCLMaximum Contaminant Level Violation, AverageStage 2 Disinfectants and Disinfection Byproducts RuleTTHM1050Returned to Compliance01-JAN-201831-MAR-2018Yes
MRLead Consumer NoticeLead and Copper RuleLead and Copper Rule1047Returned to Compliance30-DEC-2017 - No
MCLMaximum Contaminant Level Violation, AverageStage 2 Disinfectants and Disinfection Byproducts RuleTTHM1046Returned to Compliance01-OCT-201731-DEC-2017Yes
MCLMaximum Contaminant Level Violation, AverageStage 2 Disinfectants and Disinfection Byproducts RuleTTHM1042Returned to Compliance01-JAN-201731-MAR-2017Yes
MCLMaximum Contaminant Level Violation, AverageStage 2 Disinfectants and Disinfection Byproducts RuleTTHM1029Returned to Compliance01-OCT-201631-DEC-2016Yes
MCLMaximum Contaminant Level Violation, AverageStage 2 Disinfectants and Disinfection Byproducts RuleTTHM1022Returned to Compliance01-JUL-201630-SEP-2016Yes
MCLMaximum Contaminant Level Violation, AverageStage 2 Disinfectants and Disinfection Byproducts RuleTTHM1020Returned to Compliance01-APR-201630-JUN-2016Yes
OtherConsumer Confidence Report Inadequate ReportingConsumer Confidence RuleConsumer Confidence Rule1018Returned to Compliance01-JUL-2012 - No
MRMonitoring, Routine Major (TCR)Total Coliform RuleColiform (TCR)1010Returned to Compliance01-NOV-200830-NOV-2008No
MRMonitoring of Treatment (SWTR-Filter)Surface Water Treatment RuleSurface Water Treatment Rule205Returned to Compliance01-JAN-200531-JAN-2005No
MCLMaximum Contaminant Level Violation, AverageStage 1 Disinfectants and Disinfection Byproducts RuleTTHM805Returned to Compliance01-JAN-200531-MAR-2005Yes
MCLMaximum Contaminant Level Violation, AverageStage 1 Disinfectants and Disinfection Byproducts RuleTTHM105Returned to Compliance01-OCT-200431-DEC-2004Yes
MCLMaximum Contaminant Level Violation, AverageStage 1 Disinfectants and Disinfection Byproducts RuleTTHM504Returned to Compliance01-JUL-200430-SEP-2004Yes
MCLMaximum Contaminant Level Violation, AverageStage 1 Disinfectants and Disinfection Byproducts RuleTTHM604Returned to Compliance01-APR-200430-JUN-2004Yes
OtherConsumer Confidence Report Complete Failure to ReportConsumer Confidence RuleConsumer Confidence Rule403Returned to Compliance01-JUL-2003 - No
MRMonitoring, Turbidity (Enhanced SWTR)Interim and Long Term 1 Enhanced Surface Water Treatment RuleInterim Enhanced Surface Water Treatment Rule303Returned to Compliance01-JUN-200330-JUN-2003No
MRInitial Tap Sampling for Pb and CuLead and Copper RuleLead and Copper Rule9999193Returned to Compliance01-JUL-199230-JUN-1993No
  • 1 - 19 of 19

Enforcement Actions


Enforcement Actions

Latest Enforcement IDAssociated To Violation IDEnforcement Action Type CodeEnforcement Action DescriptionEnforcement DateOriginator DescriptionEnforcement Comment
14541052SFOState Administrative/Compliance Order with penalty issued29-AUG-2019StateTCEQ DOCKET NO. 2018-1049-PWS-E. FILE CLOSED 9/17/2019
14541050SFOState Administrative/Compliance Order with penalty issued29-AUG-2019StateTCEQ DOCKET NO. 2018-1049-PWS-E. FILE CLOSED 9/17/2019
14541046SFOState Administrative/Compliance Order with penalty issued29-AUG-2019StateTCEQ DOCKET NO. 2018-1049-PWS-E. FILE CLOSED 9/17/2019
14531054SOXState Compliance achieved06-NOV-2018State11/26/18; SOX'D TTHM VIOLATIONS BASED ON 4Q2018 -01 LRAA
14421047SOXState Compliance achieved26-FEB-2018State -
14371042SFOState Administrative/Compliance Order with penalty issued12-JUL-2017StateDOCKET NO 2017-0163-PWS-E; FILE CLOSED 7/26/2017
14371029SFOState Administrative/Compliance Order with penalty issued12-JUL-2017StateDOCKET NO 2017-0163-PWS-E; FILE CLOSED 7/26/2017
14371020SFOState Administrative/Compliance Order with penalty issued12-JUL-2017StateDOCKET NO 2017-0163-PWS-E; FILE CLOSED 7/26/2017
14371022SFOState Administrative/Compliance Order with penalty issued12-JUL-2017StateDOCKET NO 2017-0163-PWS-E; FILE CLOSED 7/26/2017
14131018SOXState Compliance achieved10-JUL-2013State07/10/13;MGONZALES; SYSTEM SUBMITTED 2012 CCR
1411205SOXState Compliance achieved06-AUG-2010State -
1411303SOXState Compliance achieved06-AUG-2010State -
1410604SOXState Compliance achieved07-JUL-2010StateSDWIS 2010 CLEANUP
1410504SOXState Compliance achieved07-JUL-2010StateSDWIS 2010 CLEANUP
1410105SOXState Compliance achieved07-JUL-2010StateSDWIS 2010 CLEANUP
1410805SOXState Compliance achieved07-JUL-2010StateSDWIS 2010 CLEANUP
14091010SOXState Compliance achieved01-JUN-2009StateAUTOMATIC RETURN TO COMPLIANCE 05/25/2010
1304403SOXState Compliance achieved20-JUL-2004StateCCR2002 - COMPLY
1939999193SOXState Compliance achieved30-JUN-1993State -
  • 1 - 19 of 19

PWS Facilities


All Facilities

Facility NameFacility IDIs SourceFacility Type DescriptionWater Type DescriptionAvailability DescriptionFacility Activity Status
INTAKE 1 - LAKE COLEMAN33424YesIntakeSurface waterPermanentActive
INTAKE 3 - LK SCARBAROUGH33435YesIntakeSurface waterSeasonalActive
INTAKE 2 - HORDS CREEK LAKE33425YesIntakeSurface waterPermanentActive
RAW-TAP157216NoCommon Headers - - Active
RAW-TAP117442NoCommon Headers - - Inactive
DISTRIBUTION SYSTEM39009NoDistribution System/Zone - - Active
701 WESTERN DR - 2400 GPM -FEED PUMP144330NoPump Facility - - Active
701 WESTERN DR - 2400 GPM - FEED PUMP144331NoPump Facility - - Active
AUSTIN ST HILL - 750 GPM - SP144332NoPump Facility - - Active
AUSTIN ST HILL - 750 GPM - SP144333NoPump Facility - - Active
AUSTIN ST HILL - 2000 GPM - SP144334NoPump Facility - - Active
AUSTIN ST HILL - 2000 GPM - SP144335NoPump Facility - - Active
AUSTIN ST HILL - 2000 GPM - SP144336NoPump Facility - - Active
701 WESTERN DR - 2300 GPM -FEED PUMP159931NoPump Facility - - Active
EGS SITE - 1740 GPM - SP78250NoPump Facility - - Inactive
EGS SITE - 1740 GPM - SP78251NoPump Facility - - Inactive
EGS SITE - 750 GPM - SP78252NoPump Facility - - Inactive
WTP - 500 GPM - SP78253NoPump Facility - - Inactive
WTP AT 701 MISSISSIPPI ST; COLEMAN133869NoSampling Station - - Active
WTP AT 701 MISSISSIPPI ST, COLEMAN49319NoSampling Station - - Active
701 WESTERN DR - 0.03 MG - GR144329NoStorage - - Active
WTP - 0.100 MG - CW151273NoStorage - - Active
E 20TH STREET - 0.5 MG - EL96065NoStorage - - Active
701 WESTERN DR - 0.250 MG - EL96066NoStorage - - Active
AUSTIN ST HILL - 0.367 MG - EL GR96067NoStorage - - Active
AUSTIN ST HILL- 0.343 MG - EL GR96068NoStorage - - Active
PLANT - 701 WESTERN DR155884NoTreatment Plant - - Active
PLANT - 800 MISSISSIPPI ST1025NoTreatment Plant - - Inactive
  • 1 - 28 of 28

PWS Treatment Processes


Treatment Processes

Facility NameFacility IDTreatment ProcessTreatment Objective
PLANT - 800 MISSISSIPPI ST1025Gaseous Chlorination, PreDisinfection
PLANT - 800 MISSISSIPPI ST1025InnovativeDisinfection
PLANT - 800 MISSISSIPPI ST1025InnovativeParticulate removal
PLANT - 800 MISSISSIPPI ST1025InnovativeParticulate removal
PLANT - 800 MISSISSIPPI ST1025InnovativeDisinfection
PLANT - 800 MISSISSIPPI ST1025Gaseous Chlorination, PreDisinfection
PLANT - 800 MISSISSIPPI ST1025InnovativeDisinfection
PLANT - 800 MISSISSIPPI ST1025InnovativeDisinfection
PLANT - 800 MISSISSIPPI ST1025SedimentationParticulate removal
PLANT - 800 MISSISSIPPI ST1025InnovativeParticulate removal
PLANT - 800 MISSISSIPPI ST1025InnovativeDisinfection
PLANT - 701 WESTERN DR155884InnovativeDisinfection
PLANT - 701 WESTERN DR155884Gaseous Chlorination, PreDisinfection
PLANT - 701 WESTERN DR155884Filtration, UltrafiltrationParticulate removal
PLANT - 701 WESTERN DR155884Chlorine DioxideDisinfection
  • 1 - 15 of 15

For more information on a Water System:
Ask the operators of your water system, contact your primacy agency or file a Freedom of Information Act (FOIA) request.
Drinking water in general: Find out more about your drinking water web site or call the Safe Drinking Water Hotline (1-800-426-4791). EPA has also prepared a table about various regulated drinking water contaminants.
Tools for accessing EPA drinking water data: Safe Drinking Water Information System (SDWIS) Federal Reporting Services and Drinking Water Performance and Results Report.
Research Data: As well as monitoring the levels of drinking water contaminants for which EPA has set standards, EPA, states, and water systems also carry out studies of contaminants that may need to be regulated in the future. For more information about these contaminants, please see the National Contaminant Occurrence Database.