U.S. flag

An official website of the United States government

Safe Drinking Water Information System (SDWIS) Federal Reporting Services

Your Drinking Water Query results from SDWIS Fed Reporting Services

PWS IDTX0010036
PWS NameBRUSHY CREEK WSC
PWS TypeCommunity water system
Owner TypeLocal government
Primary SourceGround water
Primacy TypeState
Is Wholesaler?No
Population Served4866
County ServedAnderson

Note


The tables below list all violations that the state reported to EPA for this water system. Health-based violations are listed first, followed by treatment technique, MRDL, monitoring, reporting, and other violations.

Health-based Violations of maximum contaminant levels (MCLs) or maximum residual disinfectant levels (MRDLs), which specify the highest concentrations of contaminants or disinfectants, respectively, allowed in drinking water; or of treatment technique (TT) rules, which specify required processes intended to reduce the amounts of contaminants in drinking water. MCLs, MRDLs, and treatment technique rules are all health-based drinking water standards.
Maximum Contaminant Level or MCL The highest level of a contaminant that is allowed in drinking water. MCLs are set as close to the MCLGs as feasible using the best available treatment technology.
Treatment Technique A required process intended to reduce the level of a contaminant in drinking water.
Maximum residual disinfectant level or MRDL The highest level of a disinfectant allowed in drinking water. There is convincing evidence that addition of a disinfectant is necessary for control of microbial contaminants.
Monitoring & reporting Failure to conduct regular monitoring of drinking water quality, as required by SDWA, or to submit monitoring results in a timely fashion to the primacy agency or EPA.
Public notification & other Failure to provide notification to the public as required by the Violations of Public Notification Rule and the Consumer Confidence Report Rule, and violations of other requirements such as those violations related to variances and exemptions.

PWS Violation


Violations

Violation Category CodeViolation Type DescriptionRule NameContaminant NameViolation IDCompliance Status DescriptionCompliance Period Begin DateCompliance Period End DateIs Health Based Ind
MCLMaximum Contaminant Level Violation, AverageStage 2 Disinfectants and Disinfection Byproducts RuleTTHM90Returned to Compliance01-APR-202330-JUN-2023Yes
OtherPublic Notification Violation for NPDWR ViolationPublic Notice Rule and Revised PN RulePublic Notice67Open02-SEP-2022 - No
MRFollow-up Or Routine LCR Tap M/RLead and Copper RuleLead and Copper Rule40Returned to Compliance01-JUL-2021 - No
OtherPublic Notification Violation for NPDWR ViolationPublic Notice Rule and Revised PN RulePublic Notice34Returned to Compliance28-MAR-2019 - No
MCLMaximum Contaminant Level Violation, AverageStage 2 Disinfectants and Disinfection Byproducts RuleTTHM33Returned to Compliance01-JAN-201931-MAR-2019Yes
MCLMaximum Contaminant Level Violation, AverageStage 2 Disinfectants and Disinfection Byproducts RuleTTHM29Returned to Compliance01-OCT-201831-DEC-2018Yes
MRMonitoring, Source Water (GWR)Ground Water RuleE. COLI25Returned to Compliance27-DEC-2017 - No
MRLead Consumer NoticeLead and Copper RuleLead and Copper Rule11Returned to Compliance30-DEC-2014 - No
MRLead Consumer NoticeLead and Copper RuleLead and Copper Rule10Returned to Compliance30-DEC-2013 - No
  • 1 - 9 of 9

Enforcement Actions


Enforcement Actions

Latest Enforcement IDAssociated To Violation IDEnforcement Action Type CodeEnforcement Action DescriptionEnforcement DateOriginator DescriptionEnforcement Comment
3690SOXState Compliance achieved24-AUG-2023StateVIOL SOX'D BASED ON TTHM DBP2-02 3Q2023 LRAA
2867SIAState Violation/Reminder Notice03-NOV-2022State -
2740SOXState Compliance achieved23-DEC-2021State -
2425SOXState Compliance achieved17-DEC-2019State -
2329SFOState Administrative/Compliance Order with penalty issued05-NOV-2019StateTCEQ DOCKET NO. 2019-0664-PWS-E. FILE CLOSED 1/2/2020.
2333SFOState Administrative/Compliance Order with penalty issued05-NOV-2019StateTCEQ DOCKET NO. 2019-0664-PWS-E. FILE CLOSED 1/2/2020.
2334SFOState Administrative/Compliance Order with penalty issued05-NOV-2019StateTCEQ DOCKET NO. 2019-0664-PWS-E. FILE CLOSED 1/2/2020.
410SOXState Compliance achieved15-JUL-2015State -
311SOXState Compliance achieved26-FEB-2015State -
  • 1 - 9 of 9

PWS Facilities


All Facilities

Facility NameFacility IDIs SourceFacility Type DescriptionWater Type DescriptionAvailability DescriptionFacility Activity Status
3 - CR 44114375YesWell Ground waterOtherInactive
3A - CR 441160362YesWell Ground waterPermanentActive
5 - 1182 ANDERSON COUNTY14377YesWell Ground waterPermanentActive
4 - CR 40414376YesWell Ground waterPermanentActive
2 - CR 40414374YesWell Ground waterPermanentActive
1 - CR 44514363YesWell Ground waterPermanentActive
DISTRIBUTION SYSTEM36153NoDistribution System/Zone - - Active
PLANT 4 - 500 GPM GPM - SP78188NoPump Facility - - Active
PLANT 4 - 500 GPM GPM - SP78189NoPump Facility - - Active
3260 ACR 445, PALESTINE132694NoSampling Station - - Active
1330 ACR 450 , PALESTINE132695NoSampling Station - - Active
790 ACR 441, PALESTINE132696NoSampling Station - - Active
16992 ACR 404, PALESTINE132697NoSampling Station - - Active
1330 ACR 450, PALESTINE132698NoSampling Station - - Active
1330 ACR 450 , PALESTINE47346NoSampling Station - - Active
16992 ACR 404, PALESTINE47347NoSampling Station - - Active
790 ACR 441, PALESTINE47348NoSampling Station - - Active
3260 ACR 445, PALESTINE47349NoSampling Station - - Active
1330 ACR 450, PALESTINE66662NoSampling Station - - Active
PLANT 5 - 0.100 MG - EL95988NoStorage - - Active
PLANT 4 - 0.005 MG - HD95989NoStorage - - Active
PLANT 4 - 0.005 MG - HD95990NoStorage - - Active
PLANT 4 - 0.050 MG - GR95991NoStorage - - Active
PLANT 4 - 0.050 MG - GR95992NoStorage - - Active
PLANT 3 - 0.105 MG - ST95993NoStorage - - Active
PLANT 2 - 0.025 MG - ST95994NoStorage - - Active
PLANT 1 - 0.030 MG - ST95995NoStorage - - Active
PLANT 2 - WILKERSON MOUNTAIN11491NoTreatment Plant - - Active
PLANT 4 - COUNTY RD 4043015NoTreatment Plant - - Active
PLANT 3 - ELMWOOD PLANT3431NoTreatment Plant - - Active
PLANT 5 - CR 45066593NoTreatment Plant - - Active
PLANT 1 - QUICK MOUNTAIN9413NoTreatment Plant - - Active
1182 ANDERSON COUNTY12207NoTreatment Plant - - Inactive
  • 1 - 33 of 33

PWS Treatment Processes


Treatment Processes

Facility NameFacility IDTreatment ProcessTreatment Objective
PLANT 2 - WILKERSON MOUNTAIN11491Gaseous Chlorination, PreDisinfection
PLANT 4 - COUNTY RD 4043015Gaseous Chlorination, PreDisinfection
PLANT 3 - ELMWOOD PLANT3431Inhibitor, PolyphosphateCorrosion control
PLANT 3 - ELMWOOD PLANT3431Gaseous Chlorination, PreDisinfection
PLANT 5 - CR 45066593Gaseous Chlorination, PreDisinfection
PLANT 1 - QUICK MOUNTAIN9413Gaseous Chlorination, PreDisinfection
  • 1 - 6 of 6

For more information on a Water System:
Ask the operators of your water system, contact your primacy agency or file a Freedom of Information Act (FOIA) request.
Drinking water in general: Find out more about your drinking water web site or call the Safe Drinking Water Hotline (1-800-426-4791). EPA has also prepared a table about various regulated drinking water contaminants.
Tools for accessing EPA drinking water data: Safe Drinking Water Information System (SDWIS) Federal Reporting Services and Drinking Water Performance and Results Report.
Research Data: As well as monitoring the levels of drinking water contaminants for which EPA has set standards, EPA, states, and water systems also carry out studies of contaminants that may need to be regulated in the future. For more information about these contaminants, please see the National Contaminant Occurrence Database.