U.S. flag

An official website of the United States government

Safe Drinking Water Information System (SDWIS) Federal Reporting Services

Your Drinking Water Query results from SDWIS Fed Reporting Services

PWS IDSC1110001
PWS NameGAFFNEY BPW (SC1110001)
PWS TypeCommunity water system
Owner TypeLocal government
Primary SourceSurface water
Primacy TypeState
Is Wholesaler?No
Population Served24290
County ServedCherokee

Note


The tables below list all violations that the state reported to EPA for this water system. Health-based violations are listed first, followed by treatment technique, MRDL, monitoring, reporting, and other violations.

Health-based Violations of maximum contaminant levels (MCLs) or maximum residual disinfectant levels (MRDLs), which specify the highest concentrations of contaminants or disinfectants, respectively, allowed in drinking water; or of treatment technique (TT) rules, which specify required processes intended to reduce the amounts of contaminants in drinking water. MCLs, MRDLs, and treatment technique rules are all health-based drinking water standards.
Maximum Contaminant Level or MCL The highest level of a contaminant that is allowed in drinking water. MCLs are set as close to the MCLGs as feasible using the best available treatment technology.
Treatment Technique A required process intended to reduce the level of a contaminant in drinking water.
Maximum residual disinfectant level or MRDL The highest level of a disinfectant allowed in drinking water. There is convincing evidence that addition of a disinfectant is necessary for control of microbial contaminants.
Monitoring & reporting Failure to conduct regular monitoring of drinking water quality, as required by SDWA, or to submit monitoring results in a timely fashion to the primacy agency or EPA.
Public notification & other Failure to provide notification to the public as required by the Violations of Public Notification Rule and the Consumer Confidence Report Rule, and violations of other requirements such as those violations related to variances and exemptions.

PWS Violation


Violations

Violation Category CodeViolation Type DescriptionRule NameContaminant NameViolation IDCompliance Status DescriptionCompliance Period Begin DateCompliance Period End DateIs Health Based Ind
MCLMaximum Contaminant Level Violation, AverageStage 2 Disinfectants and Disinfection Byproducts RuleTTHM4903507Returned to Compliance01-OCT-201431-DEC-2014Yes
MRMonitoring, Repeat Minor (TCR)Total Coliform RuleColiform (TCR)4903506Returned to Compliance01-JUL-200831-JUL-2008No
OtherConsumer Confidence Report Complete Failure to ReportConsumer Confidence RuleConsumer Confidence Rule4903505Returned to Compliance01-JUL-2005 - No
MCLMaximum Contaminant Level Violation, AverageStage 1 Disinfectants and Disinfection Byproducts RuleTotal Haloacetic Acids (HAA5)4892904Returned to Compliance01-OCT-200331-DEC-2003Yes
MCLMaximum Contaminant Level Violation, AverageStage 1 Disinfectants and Disinfection Byproducts RuleTotal Haloacetic Acids (HAA5)4903304Returned to Compliance01-JUL-200330-SEP-2003Yes
MCLMaximum Contaminant Level Violation, AverageStage 1 Disinfectants and Disinfection Byproducts RuleTotal Haloacetic Acids (HAA5)4839903Returned to Compliance01-APR-200330-JUN-2003Yes
MCLMaximum Contaminant Level Violation, AverageFormer Total Trihalomethane RuleTTHM2855395Returned to Compliance01-OCT-199431-DEC-1994Yes
MCLMaximum Contaminant Level Violation, AverageFormer Total Trihalomethane RuleTTHM2855295Returned to Compliance01-JUL-199430-SEP-1994Yes
MRMonitoring, RegularNitrate RuleNitrate2451793Returned to Compliance01-JUL-199330-SEP-1993No
MRMonitoring, RegularNitrate RuleNitrate2451693Returned to Compliance01-APR-199330-JUN-1993No
MRMonitoring, RegularInorganic ChemicalsBarium2477693Returned to Compliance01-JAN-199331-JAN-1993No
MRMonitoring, RegularInorganic ChemicalsChromium2477993Returned to Compliance01-JAN-199331-JAN-1993No
MRMonitoring, RegularInorganic ChemicalsSelenium2478293Returned to Compliance01-JAN-199331-JAN-1993No
MRMonitoring, RegularNitrate RuleNitrate2451593Returned to Compliance01-JAN-199331-MAR-1993No
MRMonitoring, RegularInorganic ChemicalsMercury2477593Returned to Compliance01-JAN-199331-JAN-1993No
MRMonitoring, RegularInorganic ChemicalsCadmium2477893Returned to Compliance01-JAN-199331-JAN-1993No
MCLMaximum Contaminant Level Violation, Acute (TCR)Total Coliform RuleColiform (TCR)1715091Known01-SEP-199130-SEP-1991Yes
  • 1 - 17 of 17

Enforcement Actions


Enforcement Actions

Latest Enforcement IDAssociated To Violation IDEnforcement Action Type CodeEnforcement Action DescriptionEnforcement DateOriginator DescriptionEnforcement Comment
26583214903507SOXState Compliance achieved01-APR-2015State -
26583094903506SOXState Compliance achieved01-OCT-2010State -
26583054903505SOXState Compliance achieved18-JUL-2005State -
26579044839903SOXState Compliance achieved07-JUN-2004State -
26579044903304SOXState Compliance achieved07-JUN-2004State -
26579044892904SOXState Compliance achieved07-JUN-2004State -
11590952855395SOXState Compliance achieved01-MAR-1995State -
11590952855295SOXState Compliance achieved01-MAR-1995State -
9207932477993SOXState Compliance achieved10-JAN-1994State -
9207932477893SOXState Compliance achieved10-JAN-1994State -
9207932477693SOXState Compliance achieved10-JAN-1994State -
9207932477593SOXState Compliance achieved10-JAN-1994State -
9207932478293SOXState Compliance achieved10-JAN-1994State -
8948932451793SOXState Compliance achieved10-OCT-1993State -
8947932451693SOXState Compliance achieved10-JUL-1993State -
8946932451593SOXState Compliance achieved10-APR-1993State -
5125911715091SIFState Public Notification received22-OCT-1991State -
  • 1 - 17 of 17

PWS Facilities


All Facilities

Facility NameFacility IDIs SourceFacility Type DescriptionWater Type DescriptionAvailability DescriptionFacility Activity Status
LAKE WELCHEL (S11101)8604YesIntakeSurface waterPermanentActive
BROAD RIVER (S11102)8605YesIntakeSurface waterPermanentActive
DISTRIBUTION10011NoDistribution System/Zone - - Active
J GRADY RANDOLPH WTP (A11002)7211NoTreatment Plant - - Active
VICTORY GAFFNEY WTP (A11003)7212NoTreatment Plant - - Active
  • 1 - 5 of 5

PWS Treatment Processes


Treatment Processes

Facility NameFacility IDTreatment ProcessTreatment Objective
J GRADY RANDOLPH WTP (A11002)7211pH Adjustment, PreParticulate removal
J GRADY RANDOLPH WTP (A11002)7211Sludge TreatmentParticulate removal
J GRADY RANDOLPH WTP (A11002)7211SedimentationParticulate removal
J GRADY RANDOLPH WTP (A11002)7211Rapid MixParticulate removal
J GRADY RANDOLPH WTP (A11002)7211Filtration, Rapid SandParticulate removal
J GRADY RANDOLPH WTP (A11002)7211CoagulationParticulate removal
J GRADY RANDOLPH WTP (A11002)7211Reducing Agent, Sodium SulfiteDe-chlorination
J GRADY RANDOLPH WTP (A11002)7211Gaseous Chlorination, PreDisinfection
J GRADY RANDOLPH WTP (A11002)7211Gaseous Chlorination, PostDisinfection
J GRADY RANDOLPH WTP (A11002)7211pH Adjustment, PostCorrosion control
J GRADY RANDOLPH WTP (A11002)7211Inhibitor, PolyphosphateCorrosion control
VICTORY GAFFNEY WTP (A11003)7212FluoridationOther
VICTORY GAFFNEY WTP (A11003)7212pH Adjustment, PreParticulate removal
VICTORY GAFFNEY WTP (A11003)7212Sludge TreatmentParticulate removal
VICTORY GAFFNEY WTP (A11003)7212SedimentationParticulate removal
VICTORY GAFFNEY WTP (A11003)7212Rapid MixParticulate removal
VICTORY GAFFNEY WTP (A11003)7212FlocculationParticulate removal
VICTORY GAFFNEY WTP (A11003)7212Filtration, Rapid SandParticulate removal
VICTORY GAFFNEY WTP (A11003)7212pH Adjustment, PostCorrosion control
VICTORY GAFFNEY WTP (A11003)7212Inhibitor, PolyphosphateCorrosion control
VICTORY GAFFNEY WTP (A11003)7212CoagulationParticulate removal
VICTORY GAFFNEY WTP (A11003)7212Reducing Agent, Sodium SulfiteDe-chlorination
VICTORY GAFFNEY WTP (A11003)7212Gaseous Chlorination, PreDisinfection
VICTORY GAFFNEY WTP (A11003)7212Gaseous Chlorination, PostDisinfection
  • 1 - 24 of 24

For more information on a Water System:
Ask the operators of your water system, contact your primacy agency or file a Freedom of Information Act (FOIA) request.
Drinking water in general: Find out more about your drinking water web site or call the Safe Drinking Water Hotline (1-800-426-4791). EPA has also prepared a table about various regulated drinking water contaminants.
Tools for accessing EPA drinking water data: Safe Drinking Water Information System (SDWIS) Federal Reporting Services and Drinking Water Performance and Results Report.
Research Data: As well as monitoring the levels of drinking water contaminants for which EPA has set standards, EPA, states, and water systems also carry out studies of contaminants that may need to be regulated in the future. For more information about these contaminants, please see the National Contaminant Occurrence Database.