U.S. flag

An official website of the United States government

Safe Drinking Water Information System (SDWIS) Federal Reporting Services

Your Drinking Water Query results from SDWIS Fed Reporting Services

PWS IDSC0810001
PWS NameMONCKS CORNER CITY OF (SC0810001)
PWS TypeCommunity water system
Owner TypeLocal government
Primary SourceSurface water purchased
Primacy TypeState
Is Wholesaler?No
Population Served8956
County ServedBerkeley

Note


The tables below list all violations that the state reported to EPA for this water system. Health-based violations are listed first, followed by treatment technique, MRDL, monitoring, reporting, and other violations.

Health-based Violations of maximum contaminant levels (MCLs) or maximum residual disinfectant levels (MRDLs), which specify the highest concentrations of contaminants or disinfectants, respectively, allowed in drinking water; or of treatment technique (TT) rules, which specify required processes intended to reduce the amounts of contaminants in drinking water. MCLs, MRDLs, and treatment technique rules are all health-based drinking water standards.
Maximum Contaminant Level or MCL The highest level of a contaminant that is allowed in drinking water. MCLs are set as close to the MCLGs as feasible using the best available treatment technology.
Treatment Technique A required process intended to reduce the level of a contaminant in drinking water.
Maximum residual disinfectant level or MRDL The highest level of a disinfectant allowed in drinking water. There is convincing evidence that addition of a disinfectant is necessary for control of microbial contaminants.
Monitoring & reporting Failure to conduct regular monitoring of drinking water quality, as required by SDWA, or to submit monitoring results in a timely fashion to the primacy agency or EPA.
Public notification & other Failure to provide notification to the public as required by the Violations of Public Notification Rule and the Consumer Confidence Report Rule, and violations of other requirements such as those violations related to variances and exemptions.

PWS Violation


Violations

Violation Category CodeViolation Type DescriptionRule NameContaminant NameViolation IDCompliance Status DescriptionCompliance Period Begin DateCompliance Period End DateIs Health Based Ind
OtherConsumer Confidence Report Complete Failure to ReportConsumer Confidence RuleConsumer Confidence Rule3069697Returned to Compliance01-JUL-2009 - No
MRMonitoring, Routine Major (TCR)Total Coliform RuleColiform (TCR)3069695Known01-JUN-199530-JUN-1995No
  • 1 - 2 of 2

Enforcement Actions


Enforcement Actions

Latest Enforcement IDAssociated To Violation IDEnforcement Action Type CodeEnforcement Action DescriptionEnforcement DateOriginator DescriptionEnforcement Comment
11115983069697SOXState Compliance achieved19-AUG-2009State -
11115953069695SIAState Violation/Reminder Notice11-AUG-1995State -
  • 1 - 2 of 2

PWS Facilities


All Facilities

Facility NameFacility IDIs SourceFacility Type DescriptionWater Type DescriptionAvailability DescriptionFacility Activity Status
0880011 (P08134)15855YesConsecutive ConnectionSurface waterOtherInactive
WELL 8(G08106) GAS CL2 RM.500,000TK937YesWell Ground waterOtherInactive
WELL 5(G08105) AIRPORT936YesWell Ground waterOtherInactive
WELL 7(G08104) JONES LUMBER935YesWell Ground waterOtherInactive
WELL 4(G08103) FIRE STATION934YesWell Ground waterOtherInactive
WELL 1(G08102) OUTSIDE 75000 GAL ST933YesWell Ground waterOtherInactive
WELL 2(G08101) INSIDE 75000 GAL STO932YesWell Ground waterOtherInactive
WELL (G08108) SANTEE COOPER 52 BY-PASS939YesWell Ground waterEmergencyActive
WELL (G08107) WINTER ST 500,000 GAL TANK938YesWell Ground waterEmergencyActive
SC0820008 SANTEE COOPER REG WTR (P08129)8464YesConsecutive ConnectionSurface waterPermanentActive
DISTRIBUTION9848NoDistribution System/Zone - - Active
PUMPS19779NoPump Facility - - Active
STORAGE TANKS19778NoStorage - - Active
PLANT 1(B08001) WELL (G08107) WINTER ST7111NoTreatment Plant - - Inactive
PLANT 2(B08002) WELL (G08108) SANTEE COO9376NoTreatment Plant - - Inactive
  • 1 - 15 of 15

PWS Treatment Processes


Treatment Processes

Facility NameFacility IDTreatment ProcessTreatment Objective
PLANT 1(B08001) WELL (G08107) WINTER ST7111Gaseous Chlorination, PostDisinfection
  • 1 - 1 of 1

For more information on a Water System:
Ask the operators of your water system, contact your primacy agency or file a Freedom of Information Act (FOIA) request.
Drinking water in general: Find out more about your drinking water web site or call the Safe Drinking Water Hotline (1-800-426-4791). EPA has also prepared a table about various regulated drinking water contaminants.
Tools for accessing EPA drinking water data: Safe Drinking Water Information System (SDWIS) Federal Reporting Services and Drinking Water Performance and Results Report.
Research Data: As well as monitoring the levels of drinking water contaminants for which EPA has set standards, EPA, states, and water systems also carry out studies of contaminants that may need to be regulated in the future. For more information about these contaminants, please see the National Contaminant Occurrence Database.