U.S. flag

An official website of the United States government

Safe Drinking Water Information System (SDWIS) Federal Reporting Services

Your Drinking Water Query results from SDWIS Fed Reporting Services

PWS IDSC0320002
PWS NameALLENDALE INDUSTRIAL PARK (SC0320002)
PWS TypeCommunity water system
Owner TypeLocal government
Primary SourceGround water
Primacy TypeState
Is Wholesaler?No
Population Served2694
County ServedAllendale

Note


The tables below list all violations that the state reported to EPA for this water system. Health-based violations are listed first, followed by treatment technique, MRDL, monitoring, reporting, and other violations.

Health-based Violations of maximum contaminant levels (MCLs) or maximum residual disinfectant levels (MRDLs), which specify the highest concentrations of contaminants or disinfectants, respectively, allowed in drinking water; or of treatment technique (TT) rules, which specify required processes intended to reduce the amounts of contaminants in drinking water. MCLs, MRDLs, and treatment technique rules are all health-based drinking water standards.
Maximum Contaminant Level or MCL The highest level of a contaminant that is allowed in drinking water. MCLs are set as close to the MCLGs as feasible using the best available treatment technology.
Treatment Technique A required process intended to reduce the level of a contaminant in drinking water.
Maximum residual disinfectant level or MRDL The highest level of a disinfectant allowed in drinking water. There is convincing evidence that addition of a disinfectant is necessary for control of microbial contaminants.
Monitoring & reporting Failure to conduct regular monitoring of drinking water quality, as required by SDWA, or to submit monitoring results in a timely fashion to the primacy agency or EPA.
Public notification & other Failure to provide notification to the public as required by the Violations of Public Notification Rule and the Consumer Confidence Report Rule, and violations of other requirements such as those violations related to variances and exemptions.

PWS Violation


Violations

Violation Category CodeViolation Type DescriptionRule NameContaminant NameViolation IDCompliance Status DescriptionCompliance Period Begin DateCompliance Period End DateIs Health Based Ind
MRFollow-up Or Routine LCR Tap M/RLead and Copper RuleLead and Copper Rule4818423Returned to Compliance01-OCT-2024 - No
MRMonitoring, Source Water (GWR)Ground Water RuleE. COLI4818418Returned to Compliance06-JUL-2022 - No
MRMonitoring and Reporting (DBP)Stage 2 Disinfectants and Disinfection Byproducts RuleTTHM4818414Returned to Compliance01-JAN-201831-DEC-2018No
MRMonitoring and Reporting (DBP)Stage 2 Disinfectants and Disinfection Byproducts RuleTotal Haloacetic Acids (HAA5)4818415Returned to Compliance01-JAN-201831-DEC-2018No
MRFollow-up Or Routine LCR Tap M/RLead and Copper RuleLead and Copper Rule4818411Returned to Compliance01-OCT-2012 - No
MRFailure Submit IDSE/Subpart V Plan RptStage 2 Disinfectants and Disinfection Byproducts RuleStage 2 Disinfectants and Disinfection Byproducts Rule4818409Returned to Compliance02-JUL-2010 - No
MCLMaximum Contaminant Level Violation, Monthly (TCR)Total Coliform RuleColiform (TCR)4818407Returned to Compliance01-MAR-201031-MAR-2010Yes
MRMonitoring of Treatment (SWTR-Unfilt/GWR)Ground Water RuleGroundwater Rule4818408Returned to Compliance01-MAR-201031-MAR-2010No
MRMonitoring, Routine (IDSE)Stage 2 Disinfectants and Disinfection Byproducts RuleStage 2 Disinfectants and Disinfection Byproducts Rule4818410Returned to Compliance02-APR-2008 - No
OtherConsumer Confidence Report Complete Failure to ReportConsumer Confidence RuleConsumer Confidence Rule4818405Returned to Compliance01-JUL-2005 - No
MRMonitoring, Routine Minor (TCR)Total Coliform RuleColiform (TCR)4818303Returned to Compliance01-JAN-200331-JAN-2003No
MRMonitoring, Routine Minor (TCR)Total Coliform RuleColiform (TCR)4777903Known01-OCT-200231-DEC-2002No
MRMonitoring, Routine Major (TCR)Total Coliform RuleColiform (TCR)4072502Returned to Compliance01-JUL-200130-SEP-2001No
MRMonitoring, Routine Major (TCR)Total Coliform RuleColiform (TCR)3686798Known01-JAN-199831-MAR-1998No
MRInitial Tap Sampling for Pb and CuLead and Copper RuleLead and Copper Rule2860895Returned to Compliance01-JUL-1994 - No
  • 1 - 15 of 15

Enforcement Actions


Enforcement Actions

Latest Enforcement IDAssociated To Violation IDEnforcement Action Type CodeEnforcement Action DescriptionEnforcement DateOriginator DescriptionEnforcement Comment
26425304818423SOXState Compliance achieved20-MAY-2025StateSamples taken 02/03/2025
26425274818418SIFState Public Notification received26-APR-2023State -
26425254818415SOXState Compliance achieved30-SEP-2019State -
26425254818414SOXState Compliance achieved30-SEP-2019State -
26425204818411SIEState Public Notification requested04-MAR-2016State -
26425184818409SOXState Compliance achieved03-APR-2012State -
26425164818410SOXState Compliance achieved09-FEB-2011State -
26425114818408SOXState Compliance achieved01-JUL-2010State -
26425114818407SOXState Compliance achieved01-JUL-2010State -
26425064818405SOXState Compliance achieved30-JUN-2010State -
26421034818303SOXState Compliance achieved01-JUL-2003State -
23851034777903SIAState Violation/Reminder Notice03-DEC-2002State -
24759024072502SOXState Compliance achieved01-MAR-2002State -
16848983686798SIAState Violation/Reminder Notice22-APR-1998State -
13177952860895SOXState Compliance achieved30-JAN-1996State -
  • 1 - 15 of 15

PWS Facilities


All Facilities

Facility NameFacility IDIs SourceFacility Type DescriptionWater Type DescriptionAvailability DescriptionFacility Activity Status
FAIRFAX TOWN OF (W03002)9623YesConsecutive ConnectionGround waterEmergencyInactive
INDUSTRIAL PARK WELL (G03106)336YesWell Ground waterPermanentActive
DISTRIBUTION9727NoDistribution System/Zone - - Active
PLANT (B03001) WELL (G03106)6981NoTreatment Plant - - Active
  • 1 - 4 of 4

PWS Treatment Processes


Treatment Processes

Facility NameFacility IDTreatment ProcessTreatment Objective
PLANT (B03001) WELL (G03106)6981Hypochlorination, PreDisinfection
  • 1 - 1 of 1

For more information on a Water System:
Ask the operators of your water system, contact your primacy agency or file a Freedom of Information Act (FOIA) request.
Drinking water in general: Find out more about your drinking water web site or call the Safe Drinking Water Hotline (1-800-426-4791). EPA has also prepared a table about various regulated drinking water contaminants.
Tools for accessing EPA drinking water data: Safe Drinking Water Information System (SDWIS) Federal Reporting Services and Drinking Water Performance and Results Report.
Research Data: As well as monitoring the levels of drinking water contaminants for which EPA has set standards, EPA, states, and water systems also carry out studies of contaminants that may need to be regulated in the future. For more information about these contaminants, please see the National Contaminant Occurrence Database.