U.S. flag

An official website of the United States government

Safe Drinking Water Information System (SDWIS) Federal Reporting Services

Your Drinking Water Query results from SDWIS Fed Reporting Services

PWS IDOH7604512
PWS NameAQUA OHIO - MASSILLON PWS
PWS TypeCommunity water system
Owner TypePrivate
Primary SourceGround water
Primacy TypeState
Is Wholesaler?No
Population Served95636
County ServedStark

Note


The tables below list all violations that the state reported to EPA for this water system. Health-based violations are listed first, followed by treatment technique, MRDL, monitoring, reporting, and other violations.

Health-based Violations of maximum contaminant levels (MCLs) or maximum residual disinfectant levels (MRDLs), which specify the highest concentrations of contaminants or disinfectants, respectively, allowed in drinking water; or of treatment technique (TT) rules, which specify required processes intended to reduce the amounts of contaminants in drinking water. MCLs, MRDLs, and treatment technique rules are all health-based drinking water standards.
Maximum Contaminant Level or MCL The highest level of a contaminant that is allowed in drinking water. MCLs are set as close to the MCLGs as feasible using the best available treatment technology.
Treatment Technique A required process intended to reduce the level of a contaminant in drinking water.
Maximum residual disinfectant level or MRDL The highest level of a disinfectant allowed in drinking water. There is convincing evidence that addition of a disinfectant is necessary for control of microbial contaminants.
Monitoring & reporting Failure to conduct regular monitoring of drinking water quality, as required by SDWA, or to submit monitoring results in a timely fashion to the primacy agency or EPA.
Public notification & other Failure to provide notification to the public as required by the Violations of Public Notification Rule and the Consumer Confidence Report Rule, and violations of other requirements such as those violations related to variances and exemptions.

PWS Violation


Violations

Violation Category CodeViolation Type DescriptionRule NameContaminant NameViolation IDCompliance Status DescriptionCompliance Period Begin DateCompliance Period End DateIs Health Based Ind
MRMonitoring and Reporting (DBP)Stage 2 Disinfectants and Disinfection Byproducts RuleTTHM756Returned to Compliance01-JAN-202131-DEC-2021No
MRMonitoring and Reporting (DBP)Stage 2 Disinfectants and Disinfection Byproducts RuleTotal Haloacetic Acids (HAA5)757Returned to Compliance01-JAN-202131-DEC-2021No
OtherConsumer Confidence Report Inadequate ReportingConsumer Confidence RuleConsumer Confidence Rule755Open06-FEB-2020 - No
  • 1 - 3 of 3

Enforcement Actions


Enforcement Actions

Latest Enforcement IDAssociated To Violation IDEnforcement Action Type CodeEnforcement Action DescriptionEnforcement DateOriginator DescriptionEnforcement Comment
13756SOXState Compliance achieved02-AUG-2022State -
13757SOXState Compliance achieved02-AUG-2022State -
7755SIAState Violation/Reminder Notice06-FEB-2020State -
  • 1 - 3 of 3

PWS Facilities


All Facilities

Facility NameFacility IDIs SourceFacility Type DescriptionWater Type DescriptionAvailability DescriptionFacility Activity Status
AQUA OHIO - MASSILLON WELL 001118387YesWell Ground waterPermanentActive
AQUA OHIO - MASSILLON WELL 001755276YesWell Ground waterPermanentInactive
AQUA OHIO - MASSILLON WELL 000518392YesWell Ground waterPermanentInactive
AQUA OHIO - MASSILLON WELL 000318391YesWell Ground waterPermanentInactive
AQUA OHIO WELL 001118386YesWell Ground waterPermanentInactive
AQUA OHIO - MASSILLON WELL 001646932YesWell Ground waterPermanentActive
AQUA OHIO - MASSILLON WELL 001545055YesWell Ground waterPermanentActive
AQUA OHIO - MASSILLON WELL 001445054YesWell Ground waterPermanentActive
AQUA OHIO - MASSILLON WELL 001018396YesWell Ground waterPermanentActive
AQUA OHIO - MASSILLON WELL 000918395YesWell Ground waterPermanentActive
AQUA OHIO - MASSILLON WELL 000818394YesWell Ground waterPermanentActive
AQUA OHIO - MASSILLON WELL 000718393YesWell Ground waterPermanentActive
AQUA OHIO - MASSILLON WELL 001318390YesWell Ground waterPermanentActive
AQUA OHIO - MASSILLON WELL 000118389YesWell Ground waterPermanentActive
AQUA OHIO - MASSILLON WELL 001218388YesWell Ground waterPermanentActive
AQUA OHIO - MASSILLON DISTRIBUTION29461NoDistribution System/Zone - - Active
16TH STREET BOOSTER22877NoPump Facility - - Active
23RD STREET BOOSTER22878NoPump Facility - - Active
FORD STREET BOOSTER22879NoPump Facility - - Active
GREEN BOOSTER22880NoPump Facility - - Active
MCDONALDSVILLE BOOSTER22882NoPump Facility - - Active
NAVE STREET BOOSTER22883NoPump Facility - - Active
WALES ROAD BOOSTER22884NoPump Facility - - Active
HIGH SERVICE PUMPS 003-00840709NoPump Facility - - Active
RICHVILLE BOOSTER STATION47231NoPump Facility - - Active
EMERALD ESTATES BOOSTER47232NoPump Facility - - Active
HILLS & DALES BOOSTER22881NoPump Facility - - Inactive
Aqua Ohio, Inc. P01117894NoSampling Station - - Inactive
BAILEY ROAD TANK1158NoStorage - - Active
EASTLAKE TANK1159NoStorage - - Active
FORD RESERVOIR1160NoStorage - - Active
KENYON TANK1161NoStorage - - Active
MCDONALDSVILLE TANK1162NoStorage - - Active
NAVE TANK1163NoStorage - - Active
23RD ST. UNDERGROUND RESERVOIR1165NoStorage - - Active
FULTON RESERVOIR47233NoStorage - - Active
GREEN TANKS (2)47234NoStorage - - Active
AMHERST TANK1157NoStorage - - Inactive
STARK COUNTY WATER TANK1164NoStorage - - Inactive
AQUA OHIO - MASSILLON7570NoTreatment Plant - - Active
  • 1 - 40 of 40

PWS Treatment Processes


Treatment Processes

Facility NameFacility IDTreatment ProcessTreatment Objective
AQUA OHIO - MASSILLON7570Rapid MixParticulate removal
AQUA OHIO - MASSILLON7570Lime - Soda Ash AdditionParticulate removal
AQUA OHIO - MASSILLON7570CoagulationParticulate removal
AQUA OHIO - MASSILLON7570FlocculationParticulate removal
AQUA OHIO - MASSILLON7570SedimentationParticulate removal
AQUA OHIO - MASSILLON7570InnovativeParticulate removal
AQUA OHIO - MASSILLON7570InnovativeParticulate removal
AQUA OHIO - MASSILLON7570InnovativeParticulate removal
AQUA OHIO - MASSILLON7570Inhibitor, PolyphosphateParticulate removal
AQUA OHIO - MASSILLON7570Filtration, Rapid SandParticulate removal
AQUA OHIO - MASSILLON7570Hypochlorination, PostDisinfection
AQUA OHIO - MASSILLON7570FluoridationDisinfection
AQUA OHIO - MASSILLON7570InnovativeDisinfection
AQUA OHIO - MASSILLON7570Rapid MixParticulate removal
AQUA OHIO - MASSILLON7570Lime - Soda Ash AdditionIron removal
AQUA OHIO - MASSILLON7570Lime - Soda Ash AdditionManganese removal
AQUA OHIO - MASSILLON7570Lime - Soda Ash AdditionInorganics removal
AQUA OHIO - MASSILLON7570Lime - Soda Ash AdditionCorrosion control
  • 1 - 18 of 18

For more information on a Water System:
Ask the operators of your water system, contact your primacy agency or file a Freedom of Information Act (FOIA) request.
Drinking water in general: Find out more about your drinking water web site or call the Safe Drinking Water Hotline (1-800-426-4791). EPA has also prepared a table about various regulated drinking water contaminants.
Tools for accessing EPA drinking water data: Safe Drinking Water Information System (SDWIS) Federal Reporting Services and Drinking Water Performance and Results Report.
Research Data: As well as monitoring the levels of drinking water contaminants for which EPA has set standards, EPA, states, and water systems also carry out studies of contaminants that may need to be regulated in the future. For more information about these contaminants, please see the National Contaminant Occurrence Database.