Your Drinking Water Query results from SDWIS Fed Reporting Services

PWS IDNY5801241
PWS NameSODUS VILLAGE
PWS TypeCommunity water system
Owner TypeLocal government
Primary SourceSurface water
Primacy TypeState
Is Wholesaler?No
Population Served1709
County ServedWayne

Note


The tables below list all violations that the state reported to EPA for this water system. Health-based violations are listed first, followed by treatment technique, MRDL, monitoring, reporting, and other violations.

Health-based Violations of maximum contaminant levels (MCLs) or maximum residual disinfectant levels (MRDLs), which specify the highest concentrations of contaminants or disinfectants, respectively, allowed in drinking water; or of treatment technique (TT) rules, which specify required processes intended to reduce the amounts of contaminants in drinking water. MCLs, MRDLs, and treatment technique rules are all health-based drinking water standards.
Maximum Contaminant Level or MCL The highest level of a contaminant that is allowed in drinking water. MCLs are set as close to the MCLGs as feasible using the best available treatment technology.
Treatment Technique A required process intended to reduce the level of a contaminant in drinking water.
Maximum residual disinfectant level or MRDL The highest level of a disinfectant allowed in drinking water. There is convincing evidence that addition of a disinfectant is necessary for control of microbial contaminants.
Monitoring & reporting Failure to conduct regular monitoring of drinking water quality, as required by SDWA, or to submit monitoring results in a timely fashion to the primacy agency or EPA.
Public notification & other Failure to provide notification to the public as required by the Violations of Public Notification Rule and the Consumer Confidence Report Rule, and violations of other requirements such as those violations related to variances and exemptions.

PWS Violation


Violations

Violation Category CodeViolation Type DescriptionRule NameContaminant NameViolation IDCompliance Status DescriptionCompliance Period Begin DateCompliance Period End DateIs Health Based Ind
MRMonitoring, RegularInorganic ChemicalsMercury816Known01-JAN-202531-MAR-2025No
RPTNotification, Known or Potential LSLLead and Copper Rule RevisionsLEAD AND COPPER RULE REVISIONS817Open16-NOV-2024 - No
MCLMaximum Contaminant Level Violation, Monthly (TCR)Total Coliform RuleColiform (TCR)806Returned to Compliance01-SEP-201130-SEP-2011Yes
MRMonitoring and Reporting (DBP)Stage 1 Disinfectants and Disinfection Byproducts RuleTotal Haloacetic Acids (HAA5)704Returned to Compliance01-JAN-200431-MAR-2004No
  • 1 - 4 of 4

Enforcement Actions


Enforcement Actions

Latest Enforcement IDAssociated To Violation IDEnforcement Action Type CodeEnforcement Action DescriptionEnforcement DateOriginator DescriptionEnforcement Comment
929817SIEState Public Notification requested21-AUG-2025State -
927816SIEState Public Notification requested17-JUN-2025State -
912806SOXState Compliance achieved14-OCT-2011State -
908704SOXState Compliance achieved02-OCT-2007State -
  • 1 - 4 of 4

PWS Facilities


All Facilities

Facility NameFacility IDIs SourceFacility Type DescriptionWater Type DescriptionAvailability DescriptionFacility Activity Status
LAKE ONTARIO30795YesIntakeSurface waterPermanentActive
RT 88 WELL28898YesWell Ground waterPermanentActive
DISTRIBUTION SYSTEM34620NoDistribution System/Zone - - Active
IDSE999975419NoDistribution System/Zone - - Active
CONNECT TO MARION-ARCADIA-SODUS@STATE ST36655NoOther - - Active
CONNECT TO MARION-ARCADIA-SODUS@OLDRIDGE36662NoOther - - Active
CONNECT TO MARION-ARCADIA-SODUS@ROUTE8868963NoOther - - Active
CONNECT TO SODUS-SHAKER-HURON@MIDDLEROAD84426NoOther - - Active
CONNECT TO SODUS-SHAKER-HURO@RIDGERDWEST84427NoOther - - Active
CONNECT TO SODUS TV B @ ROUTE 8836656NoOther - - Inactive
CONNECT TO SODUS #4 @ MIDDLE RD36667NoOther - - Inactive
CONNECT TO SODUS #5 @ LAKE RD36668NoOther - - Inactive
ORCHARD TERRACE BOOSTER PUMP STATION65383NoPump Facility - - Active
1.5 MG STORAGE TANK76222NoStorage - - Active
RT 88 WELL WTP8810NoTreatment Plant - - Active
LAKE WTP9551NoTreatment Plant - - Active
  • 1 - 16 of 16

PWS Treatment Processes


Treatment Processes

Facility NameFacility IDTreatment ProcessTreatment Objective
RT 88 WELL WTP8810FluoridationOther
RT 88 WELL WTP8810Gaseous Chlorination, PostDisinfection
LAKE WTP9551CoagulationParticulate removal
LAKE WTP9551Rapid MixParticulate removal
LAKE WTP9551FluoridationOther
LAKE WTP9551Gaseous Chlorination, PostDisinfection
LAKE WTP9551Gaseous Chlorination, PreDisinfection
LAKE WTP9551Filtration, Rapid SandParticulate removal
  • 1 - 8 of 8

For more information on a Water System:
Ask the operators of your water system, contact your primacy agency or file a Freedom of Information Act (FOIA) request.
Drinking water in general: Find out more about your drinking water web site or call the Safe Drinking Water Hotline (1-800-426-4791). EPA has also prepared a table about various regulated drinking water contaminants.
Tools for accessing EPA drinking water data: Safe Drinking Water Information System (SDWIS) Federal Reporting Services and Drinking Water Performance and Results Report.
Research Data: As well as monitoring the levels of drinking water contaminants for which EPA has set standards, EPA, states, and water systems also carry out studies of contaminants that may need to be regulated in the future. For more information about these contaminants, please see the National Contaminant Occurrence Database.