PWS IDNY2902856
PWS NameWESTBURY WD
PWS TypeCommunity water system
Owner TypePublic/Private
Primary SourceGround water
Primacy TypeState
Is Wholesaler?No
Population Served20500
County ServedNassau

Note


The tables below list all violations that the state reported to EPA for this water system. Health-based violations are listed first, followed by treatment technique, MRDL, monitoring, reporting, and other violations.

Health-based Violations of maximum contaminant levels (MCLs) or maximum residual disinfectant levels (MRDLs), which specify the highest concentrations of contaminants or disinfectants, respectively, allowed in drinking water; or of treatment technique (TT) rules, which specify required processes intended to reduce the amounts of contaminants in drinking water. MCLs, MRDLs, and treatment technique rules are all health-based drinking water standards.
Maximum Contaminant Level or MCL The highest level of a contaminant that is allowed in drinking water. MCLs are set as close to the MCLGs as feasible using the best available treatment technology.
Treatment Technique A required process intended to reduce the level of a contaminant in drinking water.
Maximum residual disinfectant level or MRDL The highest level of a disinfectant allowed in drinking water. There is convincing evidence that addition of a disinfectant is necessary for control of microbial contaminants.
Monitoring & reporting Failure to conduct regular monitoring of drinking water quality, as required by SDWA, or to submit monitoring results in a timely fashion to the primacy agency or EPA.
Public notification & other Failure to provide notification to the public as required by the Violations of Public Notification Rule and the Consumer Confidence Report Rule, and violations of other requirements such as those violations related to variances and exemptions.

PWS Violation


Violations

Violation Category CodeViolation Type DescriptionRule NameContaminant NameViolation IDCompliance Status DescriptionCompliance Period Begin DateCompliance Period End DateIs Health Based Ind
MRMonitoring, RegularNitrate RuleNitrate315Returned to Compliance01-JAN-201431-MAR-2014No
MCLMaximum Contaminant Level Violation, Monthly (TCR)Total Coliform RuleColiform (TCR)313Returned to Compliance01-JUL-201331-JUL-2013Yes
MCLMaximum Contaminant Level Violation, Monthly (TCR)Total Coliform RuleColiform (TCR)311Returned to Compliance01-NOV-201130-NOV-2011Yes
MRMonitoring, RegularNitrate RuleNitrate310Returned to Compliance01-JAN-201031-MAR-2010No
MRMonitoring, RegularNitrate RuleNitrate309Returned to Compliance01-JUL-200830-SEP-2008No
MRMonitoring, RegularNitrate RuleNitrate205Returned to Compliance01-JUL-200430-SEP-2004No
MRMonitoring, RegularNitrate RuleNitrate105Returned to Compliance01-JAN-200431-MAR-2004No
  • 1 - 7 of 7

Enforcement Actions


Enforcement Actions

Latest Enforcement IDAssociated To Violation IDEnforcement Action Type CodeEnforcement Action DescriptionEnforcement DateOriginator DescriptionEnforcement Comment
1029315SOXState Compliance achieved28-MAY-2015State -
1023313SOXState Compliance achieved16-AUG-2013State -
1019311SOXState Compliance achieved14-DEC-2011State -
1015310SOXState Compliance achieved26-MAY-2011State -
1013309SOXState Compliance achieved22-MAY-2009State -
406205SOXState Compliance achieved24-MAY-2006State -
406105SOXState Compliance achieved24-MAY-2006State -
  • 1 - 7 of 7

PWS Facilities


All Facilities

Facility NameFacility IDIs SourceFacility Type DescriptionWater Type DescriptionAvailability DescriptionFacility Activity Status
WELL 12A OOS VOCS17663YesWell Ground waterEmergencyActive
WELL 1860698YesWell Ground waterPermanentActive
WELL 1444072YesWell Ground waterPermanentActive
WELL 7A17671YesWell Ground waterPermanentActive
WELL 917670YesWell Ground waterPermanentActive
WELL 1017669YesWell Ground waterPermanentActive
WELL 1117668YesWell Ground waterPermanentActive
WELL 617667YesWell Ground waterPermanentActive
WELL 1617666YesWell Ground waterPermanentActive
WELL 1717664YesWell Ground waterPermanentActive
WELL 1517662YesWell Ground waterPermanentActive
WELL 12 OOS34350YesWell Ground waterEmergencyInactive
WELL 12A OOS VOCS34348YesWell Ground waterEmergencyInactive
WELL 1217665YesWell Ground waterEmergencyActive
WELL 6 & 7A CLEARWELL69240NoClear Well - - Active
DISTRIBUTION SYSTEM48279NoDistribution System/Zone - - Active
STATE STREET GROUND TANK111NoStorage - - Active
DRYDEN ST. ELEVATED TANK112NoStorage - - Active
WELL 14:CL2 & CAUSTIC44073NoTreatment Plant - - Active
WELL 18:CL2 & CAUSTIC60699NoTreatment Plant - - Active
WELL 6 & 7A: AIRSTRIPPER69239NoTreatment Plant - - Active
WELL 6 & 7A CLEARWELL:CL2 & CAUSTIC69241NoTreatment Plant - - Active
WELL 9:CL2 & CAUSTIC7625NoTreatment Plant - - Active
WELL 10:CL2 & CAUSTIC7626NoTreatment Plant - - Active
WELL 11:CL2 & CAUSTIC7651NoTreatment Plant - - Active
WELL 15:CL2 & CAUSTIC7657NoTreatment Plant - - Active
WELL 16:CL2 & CAUSTIC7658NoTreatment Plant - - Active
WELL 17:CL2 & CAUSTIC7659NoTreatment Plant - - Active
WELLS 10 & 14: NITRATE BLENDING76816NoTreatment Plant - - Active
WELLS 9 & 16 NITRATE BLENDING88274NoTreatment Plant - - Active
WELL 12 GAC91579NoTreatment Plant - - Active
WELL 6 & 7A GAC COMBINED EFFLUENT92215NoTreatment Plant - - Active
WELLS 15 & 18 NITRATE BLENDING92221NoTreatment Plant - - Active
WELL 12 TREATMENT OOS21673NoTreatment Plant - - Inactive
WELL 12A:CL2 & CAUSTIC - OOS VOCS21698NoTreatment Plant - - Inactive
WELL 12 TREATMENT OOS7619NoTreatment Plant - - Inactive
WELL 12A:CL2 & CAUSTIC - OOS VOCS7641NoTreatment Plant - - Inactive
WELL 6 & 7A NITRATE BLENDING84067NoTreatment Plant - - Inactive
  • 1 - 38 of 38

PWS Treatment Processes


Treatment Processes

Facility NameFacility IDTreatment ProcessTreatment Objective
WELL 12 TREATMENT OOS21673Hypochlorination, PostDisinfection
WELL 12 TREATMENT OOS21673Hypochlorination, PreDisinfection
WELL 12 TREATMENT OOS21673pH AdjustmentCorrosion control
WELL 12A:CL2 & CAUSTIC - OOS VOCS21698Hypochlorination, PreDisinfection
WELL 12A:CL2 & CAUSTIC - OOS VOCS21698pH AdjustmentCorrosion control
WELL 14:CL2 & CAUSTIC44073Hypochlorination, PostDisinfection
WELL 14:CL2 & CAUSTIC44073pH AdjustmentCorrosion control
WELL 18:CL2 & CAUSTIC60699pH AdjustmentCorrosion control
WELL 18:CL2 & CAUSTIC60699Hypochlorination, PreDisinfection
WELL 6 & 7A: AIRSTRIPPER69239Aeration, Packed TowerOrganics removal
WELL 6 & 7A CLEARWELL:CL2 & CAUSTIC69241Hypochlorination, PostDisinfection
WELL 6 & 7A CLEARWELL:CL2 & CAUSTIC69241pH Adjustment, PostCorrosion control
WELL 9:CL2 & CAUSTIC7625Hypochlorination, PreDisinfection
WELL 9:CL2 & CAUSTIC7625pH AdjustmentCorrosion control
WELL 10:CL2 & CAUSTIC7626Hypochlorination, PreDisinfection
WELL 10:CL2 & CAUSTIC7626pH AdjustmentCorrosion control
WELL 11:CL2 & CAUSTIC7651Hypochlorination, PreDisinfection
WELL 11:CL2 & CAUSTIC7651pH AdjustmentCorrosion control
WELL 15:CL2 & CAUSTIC7657Hypochlorination, PreDisinfection
WELL 15:CL2 & CAUSTIC7657pH AdjustmentCorrosion control
WELL 16:CL2 & CAUSTIC7658Hypochlorination, PreDisinfection
WELL 16:CL2 & CAUSTIC7658pH AdjustmentCorrosion control
WELL 17:CL2 & CAUSTIC7659Hypochlorination, PreDisinfection
WELL 17:CL2 & CAUSTIC7659pH AdjustmentCorrosion control
WELLS 10 & 14: NITRATE BLENDING76816InnovativeOther
WELL 6 & 7A NITRATE BLENDING84067InnovativeOther
WELLS 9 & 16 NITRATE BLENDING88274InnovativeOther
  • 1 - 27 of 27

For more information on a Water System:
Ask the operators of your water system, contact your primacy agency or file a Freedom of Information Act (FOIA) request.
Drinking water in general: Find out more about your drinking water web site or call the Safe Drinking Water Hotline (1-800-426-4791). EPA has also prepared a table about various regulated drinking water contaminants.
Tools for accessing EPA drinking water data: Safe Drinking Water Information System (SDWIS) Federal Reporting Services and Drinking Water Performance and Results Report.
Research Data: As well as monitoring the levels of drinking water contaminants for which EPA has set standards, EPA, states, and water systems also carry out studies of contaminants that may need to be regulated in the future. For more information about these contaminants, please see the National Contaminant Occurrence Database.