U.S. flag

An official website of the United States government

Safe Drinking Water Information System (SDWIS) Federal Reporting Services

Your Drinking Water Query results from SDWIS Fed Reporting Services

PWS IDNY0400884
PWS NameTWIN LAKES MOBILE HOMES
PWS TypeCommunity water system
Owner TypePrivate
Primary SourceGround water
Primacy TypeState
Is Wholesaler?No
Population Served550
County ServedCattaraugus

Note


The tables below list all violations that the state reported to EPA for this water system. Health-based violations are listed first, followed by treatment technique, MRDL, monitoring, reporting, and other violations.

Health-based Violations of maximum contaminant levels (MCLs) or maximum residual disinfectant levels (MRDLs), which specify the highest concentrations of contaminants or disinfectants, respectively, allowed in drinking water; or of treatment technique (TT) rules, which specify required processes intended to reduce the amounts of contaminants in drinking water. MCLs, MRDLs, and treatment technique rules are all health-based drinking water standards.
Maximum Contaminant Level or MCL The highest level of a contaminant that is allowed in drinking water. MCLs are set as close to the MCLGs as feasible using the best available treatment technology.
Treatment Technique A required process intended to reduce the level of a contaminant in drinking water.
Maximum residual disinfectant level or MRDL The highest level of a disinfectant allowed in drinking water. There is convincing evidence that addition of a disinfectant is necessary for control of microbial contaminants.
Monitoring & reporting Failure to conduct regular monitoring of drinking water quality, as required by SDWA, or to submit monitoring results in a timely fashion to the primacy agency or EPA.
Public notification & other Failure to provide notification to the public as required by the Violations of Public Notification Rule and the Consumer Confidence Report Rule, and violations of other requirements such as those violations related to variances and exemptions.

PWS Violation


Violations

Violation Category CodeViolation Type DescriptionRule NameContaminant NameViolation IDCompliance Status DescriptionCompliance Period Begin DateCompliance Period End DateIs Health Based Ind
MCLMaximum Contaminant Level Violation, Single SampleArsenic RuleArsenic5714Returned to Compliance01-JAN-202031-MAR-2020Yes
MCLMaximum Contaminant Level Violation, AverageArsenic RuleArsenic5713Returned to Compliance01-JUL-201230-SEP-2012Yes
MCLMaximum Contaminant Level Violation, AverageArsenic RuleArsenic5712Returned to Compliance01-JAN-201231-MAR-2012Yes
MCLMaximum Contaminant Level Violation, AverageArsenic RuleArsenic5711Returned to Compliance01-OCT-201131-DEC-2011Yes
MRMonitoring, RegularArsenic RuleArsenic5710Returned to Compliance01-JAN-201031-MAR-2010No
MRMonitoring, RegularVolatile Organic Chemicals1,1,2-Trichloroethane4309Returned to Compliance01-JAN-200831-DEC-2008No
MRMonitoring, RegularVolatile Organic Chemicalscis-1,2-Dichloroethylene1509Returned to Compliance01-JAN-200831-DEC-2008No
MRMonitoring, RegularVolatile Organic Chemicals1,2,4-Trichlorobenzene1409Returned to Compliance01-JAN-200831-DEC-2008No
MRMonitoring, RegularVolatile Organic ChemicalsStyrene5409Returned to Compliance01-JAN-200831-DEC-2008No
MRMonitoring, RegularVolatile Organic ChemicalsEthylbenzene5009Returned to Compliance01-JAN-200831-DEC-2008No
MRMonitoring, RegularVolatile Organic ChemicalsToluene4909Returned to Compliance01-JAN-200831-DEC-2008No
MRMonitoring, RegularVolatile Organic ChemicalsBenzene4809Returned to Compliance01-JAN-200831-DEC-2008No
MRMonitoring, RegularVolatile Organic ChemicalsCHLOROBENZENE4709Returned to Compliance01-JAN-200831-DEC-2008No
MRMonitoring, RegularVolatile Organic ChemicalsTetrachloroethylene4509Returned to Compliance01-JAN-200831-DEC-2008No
MRMonitoring, RegularVolatile Organic ChemicalsTrichloroethylene4209Returned to Compliance01-JAN-200831-DEC-2008No
MRMonitoring, RegularVolatile Organic Chemicals1,2-Dichloropropane4109Returned to Compliance01-JAN-200831-DEC-2008No
MRMonitoring, RegularVolatile Organic ChemicalsCarbon tetrachloride4009Returned to Compliance01-JAN-200831-DEC-2008No
MRMonitoring, RegularVolatile Organic Chemicals1,1,1-Trichloroethane3909Returned to Compliance01-JAN-200831-DEC-2008No
MRMonitoring, RegularVolatile Organic Chemicals1,2-Dichloroethane3809Returned to Compliance01-JAN-200831-DEC-2008No
MRMonitoring, RegularVolatile Organic Chemicalstrans-1,2-Dichloroethylene3709Returned to Compliance01-JAN-200831-DEC-2008No
MRMonitoring, RegularVolatile Organic Chemicals1,1-Dichloroethylene3509Returned to Compliance01-JAN-200831-DEC-2008No
MRMonitoring, RegularVolatile Organic ChemicalsVinyl chloride3409Returned to Compliance01-JAN-200831-DEC-2008No
MRMonitoring, RegularVolatile Organic Chemicalsp-Dichlorobenzene3309Returned to Compliance01-JAN-200831-DEC-2008No
MRMonitoring, RegularVolatile Organic Chemicalso-Dichlorobenzene3209Returned to Compliance01-JAN-200831-DEC-2008No
MRMonitoring, RegularVolatile Organic ChemicalsDICHLOROMETHANE2809Returned to Compliance01-JAN-200831-DEC-2008No
MCLMaximum Contaminant Level Violation, Monthly (TCR)Total Coliform RuleColiform (TCR)296Returned to Compliance01-SEP-199630-SEP-1996Yes
MRMonitoring, RegularNitrate RuleNitrate194Returned to Compliance01-JAN-199331-DEC-1993No
  • 1 - 27 of 27

Enforcement Actions


Enforcement Actions

Latest Enforcement IDAssociated To Violation IDEnforcement Action Type CodeEnforcement Action DescriptionEnforcement DateOriginator DescriptionEnforcement Comment
6285714SOXState Compliance achieved23-AUG-2022State -
6245711SOXState Compliance achieved19-FEB-2013StateBlended sample collected, result below MCL.
6245713SOXState Compliance achieved19-FEB-2013StateBlended sample collected, result below MCL.
6245712SOXState Compliance achieved19-FEB-2013StateBlended sample collected, result below MCL.
6135710SIEState Public Notification requested01-SEP-2010State -
6103409SOXState Compliance achieved29-DEC-2009State -
6103509SOXState Compliance achieved29-DEC-2009State -
6103709SOXState Compliance achieved29-DEC-2009State -
6103809SOXState Compliance achieved29-DEC-2009State -
6103909SOXState Compliance achieved29-DEC-2009State -
6104109SOXState Compliance achieved29-DEC-2009State -
6104209SOXState Compliance achieved29-DEC-2009State -
6104309SOXState Compliance achieved29-DEC-2009State -
6104509SOXState Compliance achieved29-DEC-2009State -
6104709SOXState Compliance achieved29-DEC-2009State -
6104809SOXState Compliance achieved29-DEC-2009State -
6104909SOXState Compliance achieved29-DEC-2009State -
6105009SOXState Compliance achieved29-DEC-2009State -
6105409SOXState Compliance achieved29-DEC-2009State -
6103309SOXState Compliance achieved29-DEC-2009State -
6103209SOXState Compliance achieved29-DEC-2009State -
6102809SOXState Compliance achieved29-DEC-2009State -
6101509SOXState Compliance achieved29-DEC-2009State -
6101409SOXState Compliance achieved29-DEC-2009State -
6104009SOXState Compliance achieved29-DEC-2009State -
597296SOXState Compliance achieved31-OCT-1996State -
494194SOXState Compliance achieved31-MAR-1994State -
  • 1 - 27 of 27

PWS Facilities


All Facilities

Facility NameFacility IDIs SourceFacility Type DescriptionWater Type DescriptionAvailability DescriptionFacility Activity Status
#1 - OLSON WELL (35 FT)10314YesWell Ground waterEmergencyInactive
#2A - LAKE LANE WELL #226517YesWell Ground waterPermanentInactive
#2 - LAKE LANE WELL #110313YesWell Ground waterPermanentInactive
#3 - PIONEER WELL #310316YesWell Ground waterPermanentActive
#2A - LAKE LANE WELL #210315YesWell Ground waterPermanentActive
#3A - PIONEER WELL #3A10312YesWell Ground waterPermanentActive
#1 - OLSON WELL (35 FT)26516YesWell Ground waterEmergencyInactive
DISTRIBUTION SYSTEM63323NoDistribution System/Zone - - Active
PIONEER SAMPLING STATION67535NoSampling Station - - Inactive
LAKE LANE PRESSURE STORAGE67533NoStorage - - Active
PIONEER STORAGE TANKS67534NoStorage - - Active
OLSON PRESSURE STORAGE67532NoStorage - - Inactive
OLSON PRESSURE STORAGE99822NoStorage - - Inactive
TREATMENT PLANT - LAKE LANE2049NoTreatment Plant - - Active
TREATMENT PLANT - PIONEER2051NoTreatment Plant - - Active
TREATMENT PLANT - OLSON13463NoTreatment Plant - - Inactive
TREATMENT PLANT - OLSON2050NoTreatment Plant - - Inactive
  • 1 - 17 of 17

PWS Treatment Processes


Treatment Processes

Facility NameFacility IDTreatment ProcessTreatment Objective
TREATMENT PLANT - OLSON13463Hypochlorination, PreDisinfection
TREATMENT PLANT - LAKE LANE2049Hypochlorination, PreDisinfection
TREATMENT PLANT - PIONEER2051Hypochlorination, PreDisinfection
  • 1 - 3 of 3

For more information on a Water System:
Ask the operators of your water system, contact your primacy agency or file a Freedom of Information Act (FOIA) request.
Drinking water in general: Find out more about your drinking water web site or call the Safe Drinking Water Hotline (1-800-426-4791). EPA has also prepared a table about various regulated drinking water contaminants.
Tools for accessing EPA drinking water data: Safe Drinking Water Information System (SDWIS) Federal Reporting Services and Drinking Water Performance and Results Report.
Research Data: As well as monitoring the levels of drinking water contaminants for which EPA has set standards, EPA, states, and water systems also carry out studies of contaminants that may need to be regulated in the future. For more information about these contaminants, please see the National Contaminant Occurrence Database.