U.S. flag

An official website of the United States government

Safe Drinking Water Information System (SDWIS) Federal Reporting Services

Your Drinking Water Query results from SDWIS Fed Reporting Services

PWS IDNC0498010
PWS NameWILSON, CITY OF
PWS TypeCommunity water system
Owner TypeLocal government
Primary SourceSurface water
Primacy TypeState
Is Wholesaler?No
Population Served50001
County ServedWilson

Note


The tables below list all violations that the state reported to EPA for this water system. Health-based violations are listed first, followed by treatment technique, MRDL, monitoring, reporting, and other violations.

Health-based Violations of maximum contaminant levels (MCLs) or maximum residual disinfectant levels (MRDLs), which specify the highest concentrations of contaminants or disinfectants, respectively, allowed in drinking water; or of treatment technique (TT) rules, which specify required processes intended to reduce the amounts of contaminants in drinking water. MCLs, MRDLs, and treatment technique rules are all health-based drinking water standards.
Maximum Contaminant Level or MCL The highest level of a contaminant that is allowed in drinking water. MCLs are set as close to the MCLGs as feasible using the best available treatment technology.
Treatment Technique A required process intended to reduce the level of a contaminant in drinking water.
Maximum residual disinfectant level or MRDL The highest level of a disinfectant allowed in drinking water. There is convincing evidence that addition of a disinfectant is necessary for control of microbial contaminants.
Monitoring & reporting Failure to conduct regular monitoring of drinking water quality, as required by SDWA, or to submit monitoring results in a timely fashion to the primacy agency or EPA.
Public notification & other Failure to provide notification to the public as required by the Violations of Public Notification Rule and the Consumer Confidence Report Rule, and violations of other requirements such as those violations related to variances and exemptions.

PWS Violation


Violations

Violation Category CodeViolation Type DescriptionRule NameContaminant NameViolation IDCompliance Status DescriptionCompliance Period Begin DateCompliance Period End DateIs Health Based Ind
MCLMaximum Contaminant Level Violation, AverageFormer Total Trihalomethane RuleTTHM2100384Known01-NOV-198330-SEP-1984Yes
MCLMaximum Contaminant Level Violation, AverageFormer Total Trihalomethane RuleTTHM184Known01-NOV-198331-OCT-1984Yes
  • 1 - 2 of 2

Enforcement Actions


Enforcement Actions

PWS Facilities


All Facilities

Facility NameFacility IDIs SourceFacility Type DescriptionWater Type DescriptionAvailability DescriptionFacility Activity Status
CENTRAL NASH WATER & SEWER78361YesConsecutive ConnectionSurface waterEmergencyActive
WILSON LAKE39345YesIntakeSurface waterPermanentInactive
SILVER LAKE39342YesIntakeSurface waterPermanentInactive
BUCKHORN LAKE39341YesIntakeSurface waterPermanentInactive
WIGGINS MILL POND39344YesIntakeSurface waterPermanentActive
LAWNDALE DR @TOISNOT RESEVOIR39343YesIntakeSurface waterPermanentActive
TAR RIVER67677YesIntakeSurface waterEmergencyInactive
COMMON HEADER239952NoCommon Headers - - Inactive
COMMON HEADER_SOURCE# S01-S0339953NoCommon Headers - - Inactive
DISTRIBUTION SYSTEM61835NoDistribution System/Zone - - Active
STORAGE_ELEVATED_4303NoStorage - - Active
STORAGE_CLEARWELL_439NoStorage - - Active
STORAGE_CLEARWELL_175351NoStorage - - Active
STORAGE_CLEARWELL_275352NoStorage - - Active
STORAGE_CLEARWELL_375353NoStorage - - Active
STORAGE_ELEVATED_175354NoStorage - - Active
STORAGE_ELEVATED_275355NoStorage - - Active
STORAGE_ELEVATED_375356NoStorage - - Active
STORAGE_ELEVATED_575357NoStorage - - Active
BOOSTER_PLT_ELM CITY73351NoTreatment Plant - - Active
BOOSTER_PLT_JOHNSTON COUNTY E74351NoTreatment Plant - - Active
TREATMENT_PLT_WIGGINS MILL #28037NoTreatment Plant - - Active
TREATMENT_PLT_TOISNOT_SOURCE #S01&S038038NoTreatment Plant - - Active
  • 1 - 23 of 23

PWS Treatment Processes


Treatment Processes

Facility NameFacility IDTreatment ProcessTreatment Objective
BOOSTER_PLT_ELM CITY73351Hypochlorination, PostDisinfection
BOOSTER_PLT_JOHNSTON COUNTY E74351Hypochlorination, PostDisinfection
TREATMENT_PLT_WIGGINS MILL #28037Lime - Soda Ash AdditionDisinfection by-products control
TREATMENT_PLT_WIGGINS MILL #28037SequestrationManganese removal
TREATMENT_PLT_WIGGINS MILL #28037Activated Carbon, GranularOrganics removal
TREATMENT_PLT_WIGGINS MILL #28037Inhibitor, SilicateCorrosion control
TREATMENT_PLT_WIGGINS MILL #28037Activated Carbon, PowderedDisinfection by-products control
TREATMENT_PLT_WIGGINS MILL #28037Algae ControlDisinfection by-products control
TREATMENT_PLT_WIGGINS MILL #28037CoagulationDisinfection by-products control
TREATMENT_PLT_WIGGINS MILL #28037Filtration, Rapid SandDisinfection by-products control
TREATMENT_PLT_WIGGINS MILL #28037FlocculationDisinfection by-products control
TREATMENT_PLT_WIGGINS MILL #28037Rapid MixDisinfection by-products control
TREATMENT_PLT_WIGGINS MILL #28037SedimentationDisinfection by-products control
TREATMENT_PLT_WIGGINS MILL #28037pH Adjustment, PostDisinfection by-products control
TREATMENT_PLT_WIGGINS MILL #28037pH Adjustment, PreDisinfection by-products control
TREATMENT_PLT_WIGGINS MILL #28037Inhibitor, PolyphosphateCorrosion control
TREATMENT_PLT_WIGGINS MILL #28037pH AdjustmentCorrosion control
TREATMENT_PLT_WIGGINS MILL #28037pH Adjustment, PostCorrosion control
TREATMENT_PLT_WIGGINS MILL #28037Gaseous Chlorination, PostDisinfection
TREATMENT_PLT_WIGGINS MILL #28037Gaseous Chlorination, PreDisinfection
TREATMENT_PLT_WIGGINS MILL #28037Filtration, Rapid SandIron removal
TREATMENT_PLT_WIGGINS MILL #28037Gaseous Chlorination, PreIron removal
TREATMENT_PLT_WIGGINS MILL #28037PermanganateIron removal
TREATMENT_PLT_WIGGINS MILL #28037SedimentationIron removal
TREATMENT_PLT_WIGGINS MILL #28037Sludge TreatmentIron removal
TREATMENT_PLT_WIGGINS MILL #28037pH AdjustmentIron removal
TREATMENT_PLT_WIGGINS MILL #28037pH Adjustment, PreIron removal
TREATMENT_PLT_WIGGINS MILL #28037CoagulationInorganics removal
TREATMENT_PLT_WIGGINS MILL #28037Filtration, Rapid SandInorganics removal
TREATMENT_PLT_WIGGINS MILL #28037FlocculationInorganics removal
TREATMENT_PLT_WIGGINS MILL #28037Rapid MixInorganics removal
TREATMENT_PLT_WIGGINS MILL #28037SedimentationInorganics removal
TREATMENT_PLT_WIGGINS MILL #28037Sludge TreatmentInorganics removal
TREATMENT_PLT_WIGGINS MILL #28037pH Adjustment, PreInorganics removal
TREATMENT_PLT_WIGGINS MILL #28037Filtration, Rapid SandManganese removal
TREATMENT_PLT_WIGGINS MILL #28037Gaseous Chlorination, PreManganese removal
TREATMENT_PLT_WIGGINS MILL #28037PermanganateManganese removal
TREATMENT_PLT_WIGGINS MILL #28037SedimentationManganese removal
TREATMENT_PLT_WIGGINS MILL #28037Sludge TreatmentManganese removal
TREATMENT_PLT_WIGGINS MILL #28037pH AdjustmentManganese removal
TREATMENT_PLT_WIGGINS MILL #28037pH Adjustment, PreManganese removal
TREATMENT_PLT_WIGGINS MILL #28037Activated Carbon, PowderedOrganics removal
TREATMENT_PLT_WIGGINS MILL #28037Algae ControlOrganics removal
TREATMENT_PLT_WIGGINS MILL #28037CoagulationOrganics removal
TREATMENT_PLT_WIGGINS MILL #28037Filtration, Rapid SandOrganics removal
TREATMENT_PLT_WIGGINS MILL #28037FlocculationOrganics removal
TREATMENT_PLT_WIGGINS MILL #28037Gaseous Chlorination, PreOrganics removal
TREATMENT_PLT_WIGGINS MILL #28037PermanganateOrganics removal
TREATMENT_PLT_WIGGINS MILL #28037SedimentationOrganics removal
TREATMENT_PLT_WIGGINS MILL #28037pH Adjustment, PreOrganics removal
  • 1 - 50 of 121

For more information on a Water System:
Ask the operators of your water system, contact your primacy agency or file a Freedom of Information Act (FOIA) request.
Drinking water in general: Find out more about your drinking water web site or call the Safe Drinking Water Hotline (1-800-426-4791). EPA has also prepared a table about various regulated drinking water contaminants.
Tools for accessing EPA drinking water data: Safe Drinking Water Information System (SDWIS) Federal Reporting Services and Drinking Water Performance and Results Report.
Research Data: As well as monitoring the levels of drinking water contaminants for which EPA has set standards, EPA, states, and water systems also carry out studies of contaminants that may need to be regulated in the future. For more information about these contaminants, please see the National Contaminant Occurrence Database.