U.S. flag

An official website of the United States government

Safe Drinking Water Information System (SDWIS) Federal Reporting Services

Your Drinking Water Query results from SDWIS Fed Reporting Services

PWS IDMN1460003
PWS NameFairmont
PWS TypeCommunity water system
Owner TypeLocal government
Primary SourceSurface water
Primacy TypeState
Is Wholesaler?Yes
Population Served10328
County ServedMartin

Note


The tables below list all violations that the state reported to EPA for this water system. Health-based violations are listed first, followed by treatment technique, MRDL, monitoring, reporting, and other violations.

Health-based Violations of maximum contaminant levels (MCLs) or maximum residual disinfectant levels (MRDLs), which specify the highest concentrations of contaminants or disinfectants, respectively, allowed in drinking water; or of treatment technique (TT) rules, which specify required processes intended to reduce the amounts of contaminants in drinking water. MCLs, MRDLs, and treatment technique rules are all health-based drinking water standards.
Maximum Contaminant Level or MCL The highest level of a contaminant that is allowed in drinking water. MCLs are set as close to the MCLGs as feasible using the best available treatment technology.
Treatment Technique A required process intended to reduce the level of a contaminant in drinking water.
Maximum residual disinfectant level or MRDL The highest level of a disinfectant allowed in drinking water. There is convincing evidence that addition of a disinfectant is necessary for control of microbial contaminants.
Monitoring & reporting Failure to conduct regular monitoring of drinking water quality, as required by SDWA, or to submit monitoring results in a timely fashion to the primacy agency or EPA.
Public notification & other Failure to provide notification to the public as required by the Violations of Public Notification Rule and the Consumer Confidence Report Rule, and violations of other requirements such as those violations related to variances and exemptions.

PWS Violation


Violations

Violation Category CodeViolation Type DescriptionRule NameContaminant NameViolation IDCompliance Status DescriptionCompliance Period Begin DateCompliance Period End DateIs Health Based Ind
MRLead Consumer NoticeLead and Copper RuleLead and Copper Rule60103Returned to Compliance01-JAN-2021 - No
MCLMaximum Contaminant Level Violation, AverageNitrate RuleNitrate51007Returned to Compliance01-APR-201630-JUN-2016Yes
MCLMaximum Contaminant Level Violation, AverageStage 1 Disinfectants and Disinfection Byproducts RuleChlorite738348Known01-OCT-201331-OCT-2013Yes
TTMonthly Turbidity Exceed (Enhanced SWTR)Interim and Long Term 1 Enhanced Surface Water Treatment RuleInterim Enhanced Surface Water Treatment Rule40464Returned to Compliance01-OCT-201031-OCT-2010Yes
MRMonitoring, Routine Minor (TCR)Total Coliform RuleColiform (TCR)3291Known01-MAR-199731-MAR-1997No
  • 1 - 5 of 5

Enforcement Actions


Enforcement Actions

Latest Enforcement IDAssociated To Violation IDEnforcement Action Type CodeEnforcement Action DescriptionEnforcement DateOriginator DescriptionEnforcement Comment
738348SIE738348SIEState Public Notification requested15-SEP-2021State -
72970360103SOXState Compliance achieved14-APR-2021State -
60700951007SOXState Compliance achieved03-JUN-2016State -
38778140464SIFState Public Notification received12-JAN-2011State -
830103291SFJState Formal Notice of Violation issued15-APR-1997State -
  • 1 - 5 of 5

PWS Facilities


All Facilities

Facility NameFacility IDIs SourceFacility Type DescriptionWater Type DescriptionAvailability DescriptionFacility Activity Status
Budd Lake1YesIntakeSurface waterPermanentActive
Well #12YesWell Ground waterEmergencyActive
Distribution System5NoDistribution System/Zone - - Active
Industrial Park Booster Station12NoPump Facility - - Active
TREATMENT PLANT3NoTreatment Plant - - Active
  • 1 - 5 of 5

PWS Treatment Processes


Treatment Processes

Facility NameFacility IDTreatment ProcessTreatment Objective
TREATMENT PLANT3Hypochlorination, PostDisinfection
TREATMENT PLANT3FilteredParticulate removal
TREATMENT PLANT3SedimentationParticulate removal
TREATMENT PLANT3pH AdjustmentSoftening (hardness removal)
TREATMENT PLANT3Activated Carbon, GranularTaste / odor control
TREATMENT PLANT3FluoridationOther
TREATMENT PLANT3CoagulationParticulate removal
TREATMENT PLANT3ChloraminesDisinfection
TREATMENT PLANT3Lime - Soda Ash AdditionSoftening (hardness removal)
TREATMENT PLANT3Inhibitor, PolyphosphateCorrosion control
TREATMENT PLANT3Aeration, DiffusedTaste / odor control
TREATMENT PLANT3InnovativeOther
  • 1 - 12 of 12

For more information on a Water System:
Ask the operators of your water system, contact your primacy agency or file a Freedom of Information Act (FOIA) request.
Drinking water in general: Find out more about your drinking water web site or call the Safe Drinking Water Hotline (1-800-426-4791). EPA has also prepared a table about various regulated drinking water contaminants.
Tools for accessing EPA drinking water data: Safe Drinking Water Information System (SDWIS) Federal Reporting Services and Drinking Water Performance and Results Report.
Research Data: As well as monitoring the levels of drinking water contaminants for which EPA has set standards, EPA, states, and water systems also carry out studies of contaminants that may need to be regulated in the future. For more information about these contaminants, please see the National Contaminant Occurrence Database.