Your Drinking Water Query results from SDWIS Fed Reporting Services

PWS IDMD0010011
PWS NameCITY OF FROSTBURG
PWS TypeCommunity water system
Owner TypeLocal government
Primary SourceSurface water
Primacy TypeState
Is Wholesaler?No
Population Served11000
County ServedAllegany

Note


The tables below list all violations that the state reported to EPA for this water system. Health-based violations are listed first, followed by treatment technique, MRDL, monitoring, reporting, and other violations.

Health-based Violations of maximum contaminant levels (MCLs) or maximum residual disinfectant levels (MRDLs), which specify the highest concentrations of contaminants or disinfectants, respectively, allowed in drinking water; or of treatment technique (TT) rules, which specify required processes intended to reduce the amounts of contaminants in drinking water. MCLs, MRDLs, and treatment technique rules are all health-based drinking water standards.
Maximum Contaminant Level or MCL The highest level of a contaminant that is allowed in drinking water. MCLs are set as close to the MCLGs as feasible using the best available treatment technology.
Treatment Technique A required process intended to reduce the level of a contaminant in drinking water.
Maximum residual disinfectant level or MRDL The highest level of a disinfectant allowed in drinking water. There is convincing evidence that addition of a disinfectant is necessary for control of microbial contaminants.
Monitoring & reporting Failure to conduct regular monitoring of drinking water quality, as required by SDWA, or to submit monitoring results in a timely fashion to the primacy agency or EPA.
Public notification & other Failure to provide notification to the public as required by the Violations of Public Notification Rule and the Consumer Confidence Report Rule, and violations of other requirements such as those violations related to variances and exemptions.

PWS Violation


Violations

Violation Category CodeViolation Type DescriptionRule NameContaminant NameViolation IDCompliance Status DescriptionCompliance Period Begin DateCompliance Period End DateIs Health Based Ind
MCLMaximum Contaminant Level Violation, AverageStage 1 Disinfectants and Disinfection Byproducts RuleTotal Haloacetic Acids (HAA5)1Returned to Compliance01-OCT-200231-DEC-2002Yes
TTTreatment Technique (SWTR and GWR)Surface Water Treatment RuleSurface Water Treatment Rule9610001Returned to Compliance01-FEB-199629-FEB-1996Yes
MRMonitoring, Routine Major (TCR)Total Coliform RuleColiform (TCR)93V0001Returned to Compliance01-MAR-199331-MAR-1993No
MRWater Quality Parameter M/RLead and Copper RuleLead and Copper Rule93V0002Returned to Compliance01-JAN-199330-JUN-1993No
  • 1 - 4 of 4

Enforcement Actions


Enforcement Actions

Latest Enforcement IDAssociated To Violation IDEnforcement Action Type CodeEnforcement Action DescriptionEnforcement DateOriginator DescriptionEnforcement Comment
21SOXState Compliance achieved19-FEB-2003StateENFORCEMENTID :0330298;
96100049610001SOXState Compliance achieved31-MAR-1996State -
93E000393V0001SOXState Compliance achieved26-JUL-1993State -
93E000393V0002SOXState Compliance achieved26-JUL-1993State -
  • 1 - 4 of 4

PWS Facilities


All Facilities

Facility NameFacility IDIs SourceFacility Type DescriptionWater Type DescriptionAvailability DescriptionFacility Activity Status
PINEY RESERVOIR15418YesReservoirSurface waterPermanentActive
FROSTBURG NOPERMIT25YesWell Ground waterPermanentInactive
FROSTBURG GA73235324YesWell Ground waterPermanentInactive
FROSTBURG AL81064523YesWell Ground waterPermanentInactive
RESERVOIR 4 AL81064622YesWell Ground waterPermanentInactive
RIFLE RANGE 3 AL73117321YesWell Ground waterPermanentInactive
SAVAGE 2 GA73235420YesWell Ground waterPermanentActive
SAVAGE 1 NOPERMIT19YesWell Ground waterPermanentActive
FROSTBURG SPRINGS 115445YesSpringGround waterPermanentActive
FROSTBURG FILTER PLANT15545NoCommon Headers - - Active
DISTRIBUTION SYSTEM8220NoDistribution System/Zone - - Active
STORAGE TANK18509NoStorage - - Active
FROSTBURG FILTER PLANT25601NoTreatment Plant - - Active
  • 1 - 13 of 13

PWS Treatment Processes


Treatment Processes

Facility NameFacility IDTreatment ProcessTreatment Objective
FROSTBURG FILTER PLANT25601pH Adjustment, PostCorrosion control
FROSTBURG FILTER PLANT25601CoagulationParticulate removal
FROSTBURG FILTER PLANT25601Filtration, Rapid SandParticulate removal
FROSTBURG FILTER PLANT25601FlocculationParticulate removal
FROSTBURG FILTER PLANT25601Rapid MixParticulate removal
FROSTBURG FILTER PLANT25601SedimentationParticulate removal
FROSTBURG FILTER PLANT25601FluoridationOther
FROSTBURG FILTER PLANT25601Hypochlorination, PreDisinfection
FROSTBURG FILTER PLANT25601Hypochlorination, PostDisinfection
FROSTBURG FILTER PLANT25601Activated Carbon, GranularTaste / odor control
FROSTBURG FILTER PLANT25601Inhibitor, OrthophosphateCorrosion control
  • 1 - 11 of 11

For more information on a Water System:
Ask the operators of your water system, contact your primacy agency or file a Freedom of Information Act (FOIA) request.
Drinking water in general: Find out more about your drinking water web site or call the Safe Drinking Water Hotline (1-800-426-4791). EPA has also prepared a table about various regulated drinking water contaminants.
Tools for accessing EPA drinking water data: Safe Drinking Water Information System (SDWIS) Federal Reporting Services and Drinking Water Performance and Results Report.
Research Data: As well as monitoring the levels of drinking water contaminants for which EPA has set standards, EPA, states, and water systems also carry out studies of contaminants that may need to be regulated in the future. For more information about these contaminants, please see the National Contaminant Occurrence Database.