U.S. flag

An official website of the United States government

Safe Drinking Water Information System (SDWIS) Federal Reporting Services

Your Drinking Water Query results from SDWIS Fed Reporting Services

PWS IDLA1111015
PWS NameUNION PARISH WATERWORKS DISTRICT 1
PWS TypeCommunity water system
Owner TypeLocal government
Primary SourceGround water
Primacy TypeState
Is Wholesaler?No
Population Served1626
County ServedUnion Parish

Note


The tables below list all violations that the state reported to EPA for this water system. Health-based violations are listed first, followed by treatment technique, MRDL, monitoring, reporting, and other violations.

Health-based Violations of maximum contaminant levels (MCLs) or maximum residual disinfectant levels (MRDLs), which specify the highest concentrations of contaminants or disinfectants, respectively, allowed in drinking water; or of treatment technique (TT) rules, which specify required processes intended to reduce the amounts of contaminants in drinking water. MCLs, MRDLs, and treatment technique rules are all health-based drinking water standards.
Maximum Contaminant Level or MCL The highest level of a contaminant that is allowed in drinking water. MCLs are set as close to the MCLGs as feasible using the best available treatment technology.
Treatment Technique A required process intended to reduce the level of a contaminant in drinking water.
Maximum residual disinfectant level or MRDL The highest level of a disinfectant allowed in drinking water. There is convincing evidence that addition of a disinfectant is necessary for control of microbial contaminants.
Monitoring & reporting Failure to conduct regular monitoring of drinking water quality, as required by SDWA, or to submit monitoring results in a timely fashion to the primacy agency or EPA.
Public notification & other Failure to provide notification to the public as required by the Violations of Public Notification Rule and the Consumer Confidence Report Rule, and violations of other requirements such as those violations related to variances and exemptions.

PWS Violation


Violations

Violation Category CodeViolation Type DescriptionRule NameContaminant NameViolation IDCompliance Status DescriptionCompliance Period Begin DateCompliance Period End DateIs Health Based Ind
OtherPublic Notification Violation for NPDWR ViolationPublic Notice Rule and Revised PN RulePublic Notice8006242Open10-JAN-2026 - No
MCLMaximum Contaminant Level Violation, AverageStage 2 Disinfectants and Disinfection Byproducts RuleTTHM8006239Known01-JAN-202631-MAR-2026Yes
OtherPublic Notification Violation for NPDWR ViolationPublic Notice Rule and Revised PN RulePublic Notice8006237Open18-OCT-2025 - No
MCLMaximum Contaminant Level Violation, AverageStage 2 Disinfectants and Disinfection Byproducts RuleTTHM8006236Known01-OCT-202531-DEC-2025Yes
OtherPublic Notification Violation for NPDWR ViolationPublic Notice Rule and Revised PN RulePublic Notice8006235Open19-JUL-2025 - No
MCLMaximum Contaminant Level Violation, AverageStage 2 Disinfectants and Disinfection Byproducts RuleTTHM8006234Known01-JUL-202530-SEP-2025Yes
OtherPublic Notification Violation for NPDWR ViolationPublic Notice Rule and Revised PN RulePublic Notice8006231Open29-APR-2025 - No
MCLMaximum Contaminant Level Violation, AverageStage 2 Disinfectants and Disinfection Byproducts RuleTTHM8006229Known01-APR-202530-JUN-2025Yes
MCLMaximum Contaminant Level Violation, AverageStage 2 Disinfectants and Disinfection Byproducts RuleTTHM8006228Known01-JAN-202531-MAR-2025Yes
RPTLSL ReportingLead and Copper Rule RevisionsLEAD AND COPPER RULE REVISIONS8006226Returned to Compliance17-OCT-2024 - No
TTLSL InventoryLead and Copper Rule RevisionsLEAD AND COPPER RULE REVISIONS8006227Returned to Compliance17-OCT-2024 - Yes
MCLMaximum Contaminant Level Violation, AverageStage 2 Disinfectants and Disinfection Byproducts RuleTTHM8006225Known01-OCT-202431-DEC-2024Yes
TTTreatment Technique, Level 1 Assessment (RTCR)Revised Total Coliform RuleRevised Total Coliform Rule8006222Returned to Compliance10-AUG-2024 - Yes
MCLMaximum Contaminant Level Violation, AverageStage 2 Disinfectants and Disinfection Byproducts RuleTTHM8006224Known01-JUL-202430-SEP-2024Yes
MCLMaximum Contaminant Level Violation, AverageStage 2 Disinfectants and Disinfection Byproducts RuleTTHM8006218Known01-APR-202430-JUN-2024Yes
OtherPublic Notification Violation for NPDWR ViolationPublic Notice Rule and Revised PN RulePublic Notice8006220Returned to Compliance27-MAR-2024 - No
OtherPublic Notification Violation for NPDWR ViolationPublic Notice Rule and Revised PN RulePublic Notice8006219Returned to Compliance27-JAN-2024 - No
MCLMaximum Contaminant Level Violation, AverageStage 2 Disinfectants and Disinfection Byproducts RuleTTHM8006216Known01-JAN-202431-MAR-2024Yes
MCLMaximum Contaminant Level Violation, AverageStage 2 Disinfectants and Disinfection Byproducts RuleTTHM8006214Known01-OCT-202331-DEC-2023Yes
OtherPublic Notification Violation for NPDWR ViolationPublic Notice Rule and Revised PN RulePublic Notice8006212Open07-MAR-2023 - No
TTFailure To Address DeficiencyGround Water RuleGroundwater Rule8006204Open27-JAN-2023 - Yes
TTFailure To Address DeficiencyGround Water RuleGroundwater Rule8006206Open27-JAN-2023 - Yes
TTFailure To Address DeficiencyGround Water RuleGroundwater Rule8006202Open27-JAN-2023 - Yes
TTFailure To Address DeficiencyGround Water RuleGroundwater Rule8006207Open27-JAN-2023 - Yes
TTFailure To Address DeficiencyGround Water RuleGroundwater Rule8006208Open27-JAN-2023 - Yes
TTFailure To Address DeficiencyGround Water RuleGroundwater Rule8006203Open27-JAN-2023 - Yes
TTFailure To Address DeficiencyGround Water RuleGroundwater Rule8006205Open27-JAN-2023 - Yes
MRLead Consumer NoticeLead and Copper RuleLead and Copper Rule8006209Returned to Compliance30-NOV-2022 - No
OtherPublic Notification Violation for NPDWR ViolationPublic Notice Rule and Revised PN RulePublic Notice8006188Returned to Compliance17-JUL-2020 - No
TTFailure To Address DeficiencyGround Water RuleGroundwater Rule8006182Returned to Compliance27-APR-2020 - Yes
MCLMaximum Contaminant Level Violation, AverageStage 2 Disinfectants and Disinfection Byproducts RuleTTHM8006184Returned to Compliance01-APR-202030-JUN-2020Yes
MRLead Consumer NoticeLead and Copper RuleLead and Copper Rule8006180Returned to Compliance13-FEB-2020 - No
OtherPublic Notification Violation for NPDWR ViolationPublic Notice Rule and Revised PN RulePublic Notice8006181Open22-JAN-2020 - No
MCLMaximum Contaminant Level Violation, AverageStage 2 Disinfectants and Disinfection Byproducts RuleTTHM8006178Returned to Compliance01-JAN-202031-MAR-2020Yes
OtherPublic Notification Violation for NPDWR ViolationPublic Notice Rule and Revised PN RulePublic Notice8006176Open23-OCT-2019 - No
MCLMaximum Contaminant Level Violation, AverageStage 2 Disinfectants and Disinfection Byproducts RuleTTHM8006173Returned to Compliance01-OCT-201931-DEC-2019Yes
MCLMaximum Contaminant Level Violation, AverageStage 2 Disinfectants and Disinfection Byproducts RuleTTHM8006171Returned to Compliance01-JUL-201930-SEP-2019Yes
OtherPublic Notification Violation for NPDWR ViolationPublic Notice Rule and Revised PN RulePublic Notice8006168Returned to Compliance02-MAR-2019 - No
OtherPublic Notification Violation for NPDWR ViolationPublic Notice Rule and Revised PN RulePublic Notice8006165Returned to Compliance30-DEC-2018 - No
OtherPublic Notification Violation for NPDWR ViolationPublic Notice Rule and Revised PN RulePublic Notice8006164Returned to Compliance20-OCT-2018 - No
MCLMaximum Contaminant Level Violation, AverageStage 2 Disinfectants and Disinfection Byproducts RuleTTHM8006162Returned to Compliance01-OCT-201831-DEC-2018Yes
MRFollow-up Or Routine LCR Tap M/RLead and Copper RuleLead and Copper Rule8006160Returned to Compliance01-OCT-2018 - No
TTFailure To Address DeficiencyGround Water RuleGroundwater Rule8006157Returned to Compliance01-OCT-2018 - Yes
TTFailure To Address DeficiencyGround Water RuleGroundwater Rule8006158Returned to Compliance01-OCT-2018 - Yes
TTFailure To Address DeficiencyGround Water RuleGroundwater Rule8006159Returned to Compliance01-OCT-2018 - Yes
TTFailure To Address DeficiencyGround Water RuleGroundwater Rule8006155Open01-OCT-2018 - Yes
TTFailure To Address DeficiencyGround Water RuleGroundwater Rule8006156Returned to Compliance01-OCT-2018 - Yes
MONMonitoring, Routine (RTCR)Revised Total Coliform RuleRevised Total Coliform Rule8006151Returned to Compliance01-AUG-201831-AUG-2018No
MRMonitoring and Reporting (DBP)Stage 1 Disinfectants and Disinfection Byproducts RuleChlorine8006152Known01-JUL-201830-SEP-2018No
MCLMaximum Contaminant Level Violation, AverageStage 2 Disinfectants and Disinfection Byproducts RuleTTHM8006153Returned to Compliance01-JUL-201830-SEP-2018Yes
  • 1 - 50 of 176

Enforcement Actions


Enforcement Actions

Latest Enforcement IDAssociated To Violation IDEnforcement Action Type CodeEnforcement Action DescriptionEnforcement DateOriginator DescriptionEnforcement Comment
56017938006239SIEState Public Notification requested27-MAR-2026State -
56017948006234SIDState Site Visit for enforcement purposes23-MAR-2026StateAO No. C-20-111-006-ETT - O/C with ORAIs 18.), 21.), and 26.), O/C with ORAIs 8.), 17.), 20.), 22.), 25.) - slw.
56017948006229SIDState Site Visit for enforcement purposes23-MAR-2026StateAO No. C-20-111-006-ETT - O/C with ORAIs 18.), 21.), and 26.), O/C with ORAIs 8.), 17.), 20.), 22.), 25.) - slw.
56017948006228SIDState Site Visit for enforcement purposes23-MAR-2026StateAO No. C-20-111-006-ETT - O/C with ORAIs 18.), 21.), and 26.), O/C with ORAIs 8.), 17.), 20.), 22.), 25.) - slw.
56017948006155SIDState Site Visit for enforcement purposes23-MAR-2026StateAO No. C-20-111-006-ETT - O/C with ORAIs 18.), 21.), and 26.), O/C with ORAIs 8.), 17.), 20.), 22.), 25.) - slw.
56017948006236SIDState Site Visit for enforcement purposes23-MAR-2026StateAO No. C-20-111-006-ETT - O/C with ORAIs 18.), 21.), and 26.), O/C with ORAIs 8.), 17.), 20.), 22.), 25.) - slw.
56017918006162SIDState Site Visit for enforcement purposes20-MAR-2026StateAO No. AO No. C-20-111-006-ETT - O/C with ORAI 28.) - slw.
56017918006225SIDState Site Visit for enforcement purposes20-MAR-2026StateAO No. AO No. C-20-111-006-ETT - O/C with ORAI 28.) - slw.
56017918006224SIDState Site Visit for enforcement purposes20-MAR-2026StateAO No. AO No. C-20-111-006-ETT - O/C with ORAI 28.) - slw.
56017918006218SIDState Site Visit for enforcement purposes20-MAR-2026StateAO No. AO No. C-20-111-006-ETT - O/C with ORAI 28.) - slw.
56017918006216SIDState Site Visit for enforcement purposes20-MAR-2026StateAO No. AO No. C-20-111-006-ETT - O/C with ORAI 28.) - slw.
56017918006214SIDState Site Visit for enforcement purposes20-MAR-2026StateAO No. AO No. C-20-111-006-ETT - O/C with ORAI 28.) - slw.
56017918006178SIDState Site Visit for enforcement purposes20-MAR-2026StateAO No. AO No. C-20-111-006-ETT - O/C with ORAI 28.) - slw.
56017918006173SIDState Site Visit for enforcement purposes20-MAR-2026StateAO No. AO No. C-20-111-006-ETT - O/C with ORAI 28.) - slw.
56017918006171SIDState Site Visit for enforcement purposes20-MAR-2026StateAO No. AO No. C-20-111-006-ETT - O/C with ORAI 28.) - slw.
56017918006140SIDState Site Visit for enforcement purposes20-MAR-2026StateAO No. AO No. C-20-111-006-ETT - O/C with ORAI 28.) - slw.
56017918006145SIDState Site Visit for enforcement purposes20-MAR-2026StateAO No. AO No. C-20-111-006-ETT - O/C with ORAI 28.) - slw.
56017918006153SIDState Site Visit for enforcement purposes20-MAR-2026StateAO No. AO No. C-20-111-006-ETT - O/C with ORAI 28.) - slw.
56017898006237SIAState Violation/Reminder Notice19-FEB-2026State -
56017868006235SIAState Violation/Reminder Notice02-DEC-2025State -
56017858006159SIDState Site Visit for enforcement purposes30-OCT-2025StateAO No. C-20-111-006-ETT - I/C with ORAIs 2.), 5.), 7.), 10.), 11.0, 13.), 19.), 24.), and 27.) - slw.
56017858006157SIDState Site Visit for enforcement purposes30-OCT-2025StateAO No. C-20-111-006-ETT - I/C with ORAIs 2.), 5.), 7.), 10.), 11.0, 13.), 19.), 24.), and 27.) - slw.
56017858006156SIDState Site Visit for enforcement purposes30-OCT-2025StateAO No. C-20-111-006-ETT - I/C with ORAIs 2.), 5.), 7.), 10.), 11.0, 13.), 19.), 24.), and 27.) - slw.
56017738006184SIDState Site Visit for enforcement purposes11-APR-2025StateAO No. C-20-111-006-ETT - O/C with ORAIs 2.), 5.), 7.), 10.), 11.), 24.), and 27.) - slw.
56017698006182SIDState Site Visit for enforcement purposes19-MAR-2025StateAO No. C-20-111-006-ETT - O/C with ORAIs 8.), 17.), 18.), 21.), 22.), and 26.) - slw.
56017658006222SIFState Public Notification received21-JAN-2025State -
56017688006227SOXState Compliance achieved06-DEC-2024State -
56017678006226SOXState Compliance achieved23-OCT-2024State -
56017478006220SIAState Violation/Reminder Notice02-JUL-2024State -
56017468006219SIAState Violation/Reminder Notice12-JUN-2024State -
56017288006209SOXState Compliance achieved11-MAY-2023State -
56017198006206SIEState Public Notification requested30-JAN-2023State -
56017198006207SIEState Public Notification requested30-JAN-2023State -
56017198006202SIEState Public Notification requested30-JAN-2023State -
56017198006205SIEState Public Notification requested30-JAN-2023State -
56017198006204SIEState Public Notification requested30-JAN-2023State -
56017198006203SIEState Public Notification requested30-JAN-2023State -
56017198006208SIEState Public Notification requested30-JAN-2023State -
56017208006158SOXState Compliance achieved22-MAR-2021State -
56016938006180SIDState Site Visit for enforcement purposes18-MAR-2021StateAO No. C-20-111-006-ETT - I/C w/ ORA Item 15.) - slw.
56016888006047SFLState Administrative/Compliance Order without penalty issued04-DEC-2020StateAO No. C-20-111-006-ETT - Issued for 1.) erosion due to no splash pad for overflow from GR002; 2.) casing vent not provided on Well 1; 3.) d/c piping on Well 1 showing signs of rust, corrosion, and flaking paint; 4.) casing on Well 1 showing signs of rust; 5.) pressure gauge not provided on d/c piping of Well # 1; 6.) flowmeter not provided on d/c piping on Wells 1-3; 7.)Well 1 has hole in top of casing; 8.) casing vent on Well 2 is not covered by a 24 mesh corrosion resistant screen; 9.)casing on Wells 2 and 3 is showing signs of rust; 10.) Well 3 is inactive after being struck by lightning. Well # 3 has not been properly repaired or plugged and abandoned; 11.) outer casing, case vent piping, d/c piping, and steel base plate used to support pump of Well 4 are showing signs of heavy rust, corrosion, and flaking paint; 12.) casing vent screen on Well 4 is broken; 13.) pressure gauge on Well 4 is installed in the wrong location; 14.) electrical box for Well 4 has four open bolt holes that are a pathway for contamination; 15.) a screen is not provided on the overflow pipe of GR002; 16.) the water system does not have a cccp/ordinance; 17.) TTHMs exceeded MCL running annual averages; 18.) failure to submit OEL reports for exceedance of the OEL MCL for TTHMs and OEL MCL for HAA5s; 19.) failure to submit the required Lead Consumer Notice to customers; 20.) inadequate minimum disinfectant residuals; and 21.) Well 2 is inactive and has not been repaired or properly plugged and abandoned - slw.
56016888006048SFLState Administrative/Compliance Order without penalty issued04-DEC-2020StateAO No. C-20-111-006-ETT - Issued for 1.) erosion due to no splash pad for overflow from GR002; 2.) casing vent not provided on Well 1; 3.) d/c piping on Well 1 showing signs of rust, corrosion, and flaking paint; 4.) casing on Well 1 showing signs of rust; 5.) pressure gauge not provided on d/c piping of Well # 1; 6.) flowmeter not provided on d/c piping on Wells 1-3; 7.)Well 1 has hole in top of casing; 8.) casing vent on Well 2 is not covered by a 24 mesh corrosion resistant screen; 9.)casing on Wells 2 and 3 is showing signs of rust; 10.) Well 3 is inactive after being struck by lightning. Well # 3 has not been properly repaired or plugged and abandoned; 11.) outer casing, case vent piping, d/c piping, and steel base plate used to support pump of Well 4 are showing signs of heavy rust, corrosion, and flaking paint; 12.) casing vent screen on Well 4 is broken; 13.) pressure gauge on Well 4 is installed in the wrong location; 14.) electrical box for Well 4 has four open bolt holes that are a pathway for contamination; 15.) a screen is not provided on the overflow pipe of GR002; 16.) the water system does not have a cccp/ordinance; 17.) TTHMs exceeded MCL running annual averages; 18.) failure to submit OEL reports for exceedance of the OEL MCL for TTHMs and OEL MCL for HAA5s; 19.) failure to submit the required Lead Consumer Notice to customers; 20.) inadequate minimum disinfectant residuals; and 21.) Well 2 is inactive and has not been repaired or properly plugged and abandoned - slw.
56016888006050SFLState Administrative/Compliance Order without penalty issued04-DEC-2020StateAO No. C-20-111-006-ETT - Issued for 1.) erosion due to no splash pad for overflow from GR002; 2.) casing vent not provided on Well 1; 3.) d/c piping on Well 1 showing signs of rust, corrosion, and flaking paint; 4.) casing on Well 1 showing signs of rust; 5.) pressure gauge not provided on d/c piping of Well # 1; 6.) flowmeter not provided on d/c piping on Wells 1-3; 7.)Well 1 has hole in top of casing; 8.) casing vent on Well 2 is not covered by a 24 mesh corrosion resistant screen; 9.)casing on Wells 2 and 3 is showing signs of rust; 10.) Well 3 is inactive after being struck by lightning. Well # 3 has not been properly repaired or plugged and abandoned; 11.) outer casing, case vent piping, d/c piping, and steel base plate used to support pump of Well 4 are showing signs of heavy rust, corrosion, and flaking paint; 12.) casing vent screen on Well 4 is broken; 13.) pressure gauge on Well 4 is installed in the wrong location; 14.) electrical box for Well 4 has four open bolt holes that are a pathway for contamination; 15.) a screen is not provided on the overflow pipe of GR002; 16.) the water system does not have a cccp/ordinance; 17.) TTHMs exceeded MCL running annual averages; 18.) failure to submit OEL reports for exceedance of the OEL MCL for TTHMs and OEL MCL for HAA5s; 19.) failure to submit the required Lead Consumer Notice to customers; 20.) inadequate minimum disinfectant residuals; and 21.) Well 2 is inactive and has not been repaired or properly plugged and abandoned - slw.
56016888006051SFLState Administrative/Compliance Order without penalty issued04-DEC-2020StateAO No. C-20-111-006-ETT - Issued for 1.) erosion due to no splash pad for overflow from GR002; 2.) casing vent not provided on Well 1; 3.) d/c piping on Well 1 showing signs of rust, corrosion, and flaking paint; 4.) casing on Well 1 showing signs of rust; 5.) pressure gauge not provided on d/c piping of Well # 1; 6.) flowmeter not provided on d/c piping on Wells 1-3; 7.)Well 1 has hole in top of casing; 8.) casing vent on Well 2 is not covered by a 24 mesh corrosion resistant screen; 9.)casing on Wells 2 and 3 is showing signs of rust; 10.) Well 3 is inactive after being struck by lightning. Well # 3 has not been properly repaired or plugged and abandoned; 11.) outer casing, case vent piping, d/c piping, and steel base plate used to support pump of Well 4 are showing signs of heavy rust, corrosion, and flaking paint; 12.) casing vent screen on Well 4 is broken; 13.) pressure gauge on Well 4 is installed in the wrong location; 14.) electrical box for Well 4 has four open bolt holes that are a pathway for contamination; 15.) a screen is not provided on the overflow pipe of GR002; 16.) the water system does not have a cccp/ordinance; 17.) TTHMs exceeded MCL running annual averages; 18.) failure to submit OEL reports for exceedance of the OEL MCL for TTHMs and OEL MCL for HAA5s; 19.) failure to submit the required Lead Consumer Notice to customers; 20.) inadequate minimum disinfectant residuals; and 21.) Well 2 is inactive and has not been repaired or properly plugged and abandoned - slw.
56016888006062SFLState Administrative/Compliance Order without penalty issued04-DEC-2020StateAO No. C-20-111-006-ETT - Issued for 1.) erosion due to no splash pad for overflow from GR002; 2.) casing vent not provided on Well 1; 3.) d/c piping on Well 1 showing signs of rust, corrosion, and flaking paint; 4.) casing on Well 1 showing signs of rust; 5.) pressure gauge not provided on d/c piping of Well # 1; 6.) flowmeter not provided on d/c piping on Wells 1-3; 7.)Well 1 has hole in top of casing; 8.) casing vent on Well 2 is not covered by a 24 mesh corrosion resistant screen; 9.)casing on Wells 2 and 3 is showing signs of rust; 10.) Well 3 is inactive after being struck by lightning. Well # 3 has not been properly repaired or plugged and abandoned; 11.) outer casing, case vent piping, d/c piping, and steel base plate used to support pump of Well 4 are showing signs of heavy rust, corrosion, and flaking paint; 12.) casing vent screen on Well 4 is broken; 13.) pressure gauge on Well 4 is installed in the wrong location; 14.) electrical box for Well 4 has four open bolt holes that are a pathway for contamination; 15.) a screen is not provided on the overflow pipe of GR002; 16.) the water system does not have a cccp/ordinance; 17.) TTHMs exceeded MCL running annual averages; 18.) failure to submit OEL reports for exceedance of the OEL MCL for TTHMs and OEL MCL for HAA5s; 19.) failure to submit the required Lead Consumer Notice to customers; 20.) inadequate minimum disinfectant residuals; and 21.) Well 2 is inactive and has not been repaired or properly plugged and abandoned - slw.
56016888006063SFLState Administrative/Compliance Order without penalty issued04-DEC-2020StateAO No. C-20-111-006-ETT - Issued for 1.) erosion due to no splash pad for overflow from GR002; 2.) casing vent not provided on Well 1; 3.) d/c piping on Well 1 showing signs of rust, corrosion, and flaking paint; 4.) casing on Well 1 showing signs of rust; 5.) pressure gauge not provided on d/c piping of Well # 1; 6.) flowmeter not provided on d/c piping on Wells 1-3; 7.)Well 1 has hole in top of casing; 8.) casing vent on Well 2 is not covered by a 24 mesh corrosion resistant screen; 9.)casing on Wells 2 and 3 is showing signs of rust; 10.) Well 3 is inactive after being struck by lightning. Well # 3 has not been properly repaired or plugged and abandoned; 11.) outer casing, case vent piping, d/c piping, and steel base plate used to support pump of Well 4 are showing signs of heavy rust, corrosion, and flaking paint; 12.) casing vent screen on Well 4 is broken; 13.) pressure gauge on Well 4 is installed in the wrong location; 14.) electrical box for Well 4 has four open bolt holes that are a pathway for contamination; 15.) a screen is not provided on the overflow pipe of GR002; 16.) the water system does not have a cccp/ordinance; 17.) TTHMs exceeded MCL running annual averages; 18.) failure to submit OEL reports for exceedance of the OEL MCL for TTHMs and OEL MCL for HAA5s; 19.) failure to submit the required Lead Consumer Notice to customers; 20.) inadequate minimum disinfectant residuals; and 21.) Well 2 is inactive and has not been repaired or properly plugged and abandoned - slw.
56016888006064SFLState Administrative/Compliance Order without penalty issued04-DEC-2020StateAO No. C-20-111-006-ETT - Issued for 1.) erosion due to no splash pad for overflow from GR002; 2.) casing vent not provided on Well 1; 3.) d/c piping on Well 1 showing signs of rust, corrosion, and flaking paint; 4.) casing on Well 1 showing signs of rust; 5.) pressure gauge not provided on d/c piping of Well # 1; 6.) flowmeter not provided on d/c piping on Wells 1-3; 7.)Well 1 has hole in top of casing; 8.) casing vent on Well 2 is not covered by a 24 mesh corrosion resistant screen; 9.)casing on Wells 2 and 3 is showing signs of rust; 10.) Well 3 is inactive after being struck by lightning. Well # 3 has not been properly repaired or plugged and abandoned; 11.) outer casing, case vent piping, d/c piping, and steel base plate used to support pump of Well 4 are showing signs of heavy rust, corrosion, and flaking paint; 12.) casing vent screen on Well 4 is broken; 13.) pressure gauge on Well 4 is installed in the wrong location; 14.) electrical box for Well 4 has four open bolt holes that are a pathway for contamination; 15.) a screen is not provided on the overflow pipe of GR002; 16.) the water system does not have a cccp/ordinance; 17.) TTHMs exceeded MCL running annual averages; 18.) failure to submit OEL reports for exceedance of the OEL MCL for TTHMs and OEL MCL for HAA5s; 19.) failure to submit the required Lead Consumer Notice to customers; 20.) inadequate minimum disinfectant residuals; and 21.) Well 2 is inactive and has not been repaired or properly plugged and abandoned - slw.
56016888006065SFLState Administrative/Compliance Order without penalty issued04-DEC-2020StateAO No. C-20-111-006-ETT - Issued for 1.) erosion due to no splash pad for overflow from GR002; 2.) casing vent not provided on Well 1; 3.) d/c piping on Well 1 showing signs of rust, corrosion, and flaking paint; 4.) casing on Well 1 showing signs of rust; 5.) pressure gauge not provided on d/c piping of Well # 1; 6.) flowmeter not provided on d/c piping on Wells 1-3; 7.)Well 1 has hole in top of casing; 8.) casing vent on Well 2 is not covered by a 24 mesh corrosion resistant screen; 9.)casing on Wells 2 and 3 is showing signs of rust; 10.) Well 3 is inactive after being struck by lightning. Well # 3 has not been properly repaired or plugged and abandoned; 11.) outer casing, case vent piping, d/c piping, and steel base plate used to support pump of Well 4 are showing signs of heavy rust, corrosion, and flaking paint; 12.) casing vent screen on Well 4 is broken; 13.) pressure gauge on Well 4 is installed in the wrong location; 14.) electrical box for Well 4 has four open bolt holes that are a pathway for contamination; 15.) a screen is not provided on the overflow pipe of GR002; 16.) the water system does not have a cccp/ordinance; 17.) TTHMs exceeded MCL running annual averages; 18.) failure to submit OEL reports for exceedance of the OEL MCL for TTHMs and OEL MCL for HAA5s; 19.) failure to submit the required Lead Consumer Notice to customers; 20.) inadequate minimum disinfectant residuals; and 21.) Well 2 is inactive and has not been repaired or properly plugged and abandoned - slw.
56016888006068SFLState Administrative/Compliance Order without penalty issued04-DEC-2020StateAO No. C-20-111-006-ETT - Issued for 1.) erosion due to no splash pad for overflow from GR002; 2.) casing vent not provided on Well 1; 3.) d/c piping on Well 1 showing signs of rust, corrosion, and flaking paint; 4.) casing on Well 1 showing signs of rust; 5.) pressure gauge not provided on d/c piping of Well # 1; 6.) flowmeter not provided on d/c piping on Wells 1-3; 7.)Well 1 has hole in top of casing; 8.) casing vent on Well 2 is not covered by a 24 mesh corrosion resistant screen; 9.)casing on Wells 2 and 3 is showing signs of rust; 10.) Well 3 is inactive after being struck by lightning. Well # 3 has not been properly repaired or plugged and abandoned; 11.) outer casing, case vent piping, d/c piping, and steel base plate used to support pump of Well 4 are showing signs of heavy rust, corrosion, and flaking paint; 12.) casing vent screen on Well 4 is broken; 13.) pressure gauge on Well 4 is installed in the wrong location; 14.) electrical box for Well 4 has four open bolt holes that are a pathway for contamination; 15.) a screen is not provided on the overflow pipe of GR002; 16.) the water system does not have a cccp/ordinance; 17.) TTHMs exceeded MCL running annual averages; 18.) failure to submit OEL reports for exceedance of the OEL MCL for TTHMs and OEL MCL for HAA5s; 19.) failure to submit the required Lead Consumer Notice to customers; 20.) inadequate minimum disinfectant residuals; and 21.) Well 2 is inactive and has not been repaired or properly plugged and abandoned - slw.
56016888006069SFLState Administrative/Compliance Order without penalty issued04-DEC-2020StateAO No. C-20-111-006-ETT - Issued for 1.) erosion due to no splash pad for overflow from GR002; 2.) casing vent not provided on Well 1; 3.) d/c piping on Well 1 showing signs of rust, corrosion, and flaking paint; 4.) casing on Well 1 showing signs of rust; 5.) pressure gauge not provided on d/c piping of Well # 1; 6.) flowmeter not provided on d/c piping on Wells 1-3; 7.)Well 1 has hole in top of casing; 8.) casing vent on Well 2 is not covered by a 24 mesh corrosion resistant screen; 9.)casing on Wells 2 and 3 is showing signs of rust; 10.) Well 3 is inactive after being struck by lightning. Well # 3 has not been properly repaired or plugged and abandoned; 11.) outer casing, case vent piping, d/c piping, and steel base plate used to support pump of Well 4 are showing signs of heavy rust, corrosion, and flaking paint; 12.) casing vent screen on Well 4 is broken; 13.) pressure gauge on Well 4 is installed in the wrong location; 14.) electrical box for Well 4 has four open bolt holes that are a pathway for contamination; 15.) a screen is not provided on the overflow pipe of GR002; 16.) the water system does not have a cccp/ordinance; 17.) TTHMs exceeded MCL running annual averages; 18.) failure to submit OEL reports for exceedance of the OEL MCL for TTHMs and OEL MCL for HAA5s; 19.) failure to submit the required Lead Consumer Notice to customers; 20.) inadequate minimum disinfectant residuals; and 21.) Well 2 is inactive and has not been repaired or properly plugged and abandoned - slw.
  • 1 - 50 of 173

PWS Facilities


All Facilities

Facility NameFacility IDIs SourceFacility Type DescriptionWater Type DescriptionAvailability DescriptionFacility Activity Status
PURCHASE FROM LA1111005 FARMERVILLE18198YesConsecutive ConnectionGround waterEmergencyActive
WELL #3 - HUDSON RD7883YesWell Ground waterPermanentInactive
WELL #4 - OFFICE (WEST WELL)14110YesWell Ground waterPermanentActive
WELL #2 - BEAR CREEK7885YesWell Ground waterEmergencyInactive
WELL #1 - OFFICE (EAST WELL)7884YesWell Ground waterEmergencyActive
MUTUAL AID W/1111016 WARDS CHAPEL WS22809YesConsecutive ConnectionGround waterEmergencyActive
DISTRIBUTION SYSTEM9327NoDistribution System/Zone - - Active
Stage2 IDSE17408NoDistribution System/Zone - - Inactive
HIGH SERVICE PUMPS - OFFICE22971NoPump Facility - - Active
PRE-CHLORINATION TANK - OFFICE21514NoStorage - - Active
ELEVATED STORAGE TANK - OFFICE458NoStorage - - Active
STANDPIPE - HUDSON RD632NoStorage - - Active
GROUND STORAGE TANK - BEAR CREEK20329NoStorage - - Inactive
TREATMENT PLANT - OFFICE14109NoTreatment Plant - - Active
TREATMENT PLANT - WELL #1 (INACTIVE)4314NoTreatment Plant - - Inactive
TREATMENT PLANT - BEAR CREEK4315NoTreatment Plant - - Inactive
TREATMENT PLANT - HUDSON RD4316NoTreatment Plant - - Inactive
  • 1 - 17 of 17

PWS Treatment Processes


Treatment Processes

Facility NameFacility IDTreatment ProcessTreatment Objective
TREATMENT PLANT - OFFICE14109Activated Carbon, GranularDisinfection by-products control
TREATMENT PLANT - OFFICE14109Gaseous Chlorination, PreDisinfection
TREATMENT PLANT - OFFICE14109Gaseous Chlorination, PostDisinfection
TREATMENT PLANT - WELL #1 (INACTIVE)4314Gaseous Chlorination, PostDisinfection
TREATMENT PLANT - BEAR CREEK4315Gaseous Chlorination, PostDisinfection
TREATMENT PLANT - HUDSON RD4316Gaseous Chlorination, PostDisinfection
  • 1 - 6 of 6

For more information on a Water System:
Ask the operators of your water system, contact your primacy agency or file a Freedom of Information Act (FOIA) request.
Drinking water in general: Find out more about your drinking water web site or call the Safe Drinking Water Hotline (1-800-426-4791). EPA has also prepared a table about various regulated drinking water contaminants.
Tools for accessing EPA drinking water data: Safe Drinking Water Information System (SDWIS) Federal Reporting Services and Drinking Water Performance and Results Report.
Research Data: As well as monitoring the levels of drinking water contaminants for which EPA has set standards, EPA, states, and water systems also carry out studies of contaminants that may need to be regulated in the future. For more information about these contaminants, please see the National Contaminant Occurrence Database.