PWS IDKS2003706
PWS NameCRAWFORD CO RWD 4
PWS TypeCommunity water system
Owner TypeLocal government
Primary SourceGround water
Primacy TypeState
Is Wholesaler?No
Population Served1580
County ServedCrawford

Note


The tables below list all violations that the state reported to EPA for this water system. Health-based violations are listed first, followed by treatment technique, MRDL, monitoring, reporting, and other violations.

Health-based Violations of maximum contaminant levels (MCLs) or maximum residual disinfectant levels (MRDLs), which specify the highest concentrations of contaminants or disinfectants, respectively, allowed in drinking water; or of treatment technique (TT) rules, which specify required processes intended to reduce the amounts of contaminants in drinking water. MCLs, MRDLs, and treatment technique rules are all health-based drinking water standards.
Maximum Contaminant Level or MCL The highest level of a contaminant that is allowed in drinking water. MCLs are set as close to the MCLGs as feasible using the best available treatment technology.
Treatment Technique A required process intended to reduce the level of a contaminant in drinking water.
Maximum residual disinfectant level or MRDL The highest level of a disinfectant allowed in drinking water. There is convincing evidence that addition of a disinfectant is necessary for control of microbial contaminants.
Monitoring & reporting Failure to conduct regular monitoring of drinking water quality, as required by SDWA, or to submit monitoring results in a timely fashion to the primacy agency or EPA.
Public notification & other Failure to provide notification to the public as required by the Violations of Public Notification Rule and the Consumer Confidence Report Rule, and violations of other requirements such as those violations related to variances and exemptions.

PWS Violation


Violations

Violation Category CodeViolation Type DescriptionRule NameContaminant NameViolation IDCompliance Status DescriptionCompliance Period Begin DateCompliance Period End DateIs Health Based Ind
OtherConsumer Confidence Report Inadequate ReportingConsumer Confidence RuleConsumer Confidence Rule241Returned to Compliance02-JUL-2019 - No
MONMonitoring, Routine (RTCR)Revised Total Coliform RuleRevised Total Coliform Rule209Returned to Compliance01-JUL-201731-JUL-2017No
MRLead Consumer NoticeLead and Copper RuleLead and Copper Rule208Returned to Compliance30-DEC-2016 - No
MRMonitoring, Routine Minor (TCR)Total Coliform RuleColiform (TCR)207Returned to Compliance01-NOV-201230-NOV-2012No
MRMonitoring, Routine (IDSE)Stage 2 Disinfectants and Disinfection Byproducts RuleStage 2 Disinfectants and Disinfection Byproducts Rule#0001Returned to Compliance02-APR-2008 - No
  • 1 - 5 of 5

Enforcement Actions


Enforcement Actions

Latest Enforcement IDAssociated To Violation IDEnforcement Action Type CodeEnforcement Action DescriptionEnforcement DateOriginator DescriptionEnforcement Comment
17241SOXState Compliance achieved07-JUL-2020State -
13209SIFState Public Notification received22-JUN-2018State -
12208SOXState Compliance achieved02-JUN-2017StateRTC achieve date 06/02/2017 SOX entered 11/30/2017
6207SIBState Compliance Meeting conducted24-JUN-2013StatePHONE CONV WITH WILLIAM MORRISON RE TCR M/R & RELATED PN ISSUED.-jeh
#0002#0001EOXFederal Compliance achieved08-MAY-2008ODSWeb -
  • 1 - 5 of 5

PWS Facilities


All Facilities

Facility NameFacility IDIs SourceFacility Type DescriptionWater Type DescriptionAvailability DescriptionFacility Activity Status
WELL 021114YesWell Ground waterPermanentActive
WELL 032669YesWell Ground waterPermanentActive
WELL 011115YesWell Ground waterPermanentActive
CLEARWELL 0212397NoClear Well - - Active
CLEARWELL 0112398NoClear Well - - Active
DISTRIBUTION4866NoDistribution System/Zone - - Active
PUMP FACILITY 018327NoPump Facility - - Active
SYSTEM LOCATION11494NoSampling Station - - Active
STORAGE TANK 01 NONPWS7052NoStorage - - Inactive
TP0013382NoTreatment Plant - - Active
TP0024184NoTreatment Plant - - Active
  • 1 - 11 of 11

PWS Treatment Processes


Treatment Processes

Facility NameFacility IDTreatment ProcessTreatment Objective
TP0013382Aeration, Packed TowerTaste / odor control
TP0013382Gaseous Chlorination, PostDisinfection
TP0013382Gaseous Chlorination, PreDisinfection
TP0013382Filtration, Rapid SandParticulate removal
TP0024184Aeration, Packed TowerTaste / odor control
TP0024184Gaseous Chlorination, PostDisinfection
TP0024184Gaseous Chlorination, PreDisinfection
TP0024184Filtration, Rapid SandParticulate removal
  • 1 - 8 of 8

For more information on a Water System:
Ask the operators of your water system, contact your primacy agency or file a Freedom of Information Act (FOIA) request.
Drinking water in general: Find out more about your drinking water web site or call the Safe Drinking Water Hotline (1-800-426-4791). EPA has also prepared a table about various regulated drinking water contaminants.
Tools for accessing EPA drinking water data: Safe Drinking Water Information System (SDWIS) Federal Reporting Services and Drinking Water Performance and Results Report.
Research Data: As well as monitoring the levels of drinking water contaminants for which EPA has set standards, EPA, states, and water systems also carry out studies of contaminants that may need to be regulated in the future. For more information about these contaminants, please see the National Contaminant Occurrence Database.