U.S. flag

An official website of the United States government

Safe Drinking Water Information System (SDWIS) Federal Reporting Services

Your Drinking Water Query results from SDWIS Fed Reporting Services

PWS IDKS2003507
PWS NameCOWLEY CO RWD 1
PWS TypeCommunity water system
Owner TypeLocal government
Primary SourceGround water
Primacy TypeState
Is Wholesaler?No
Population Served1500
County ServedCowley

Note


The tables below list all violations that the state reported to EPA for this water system. Health-based violations are listed first, followed by treatment technique, MRDL, monitoring, reporting, and other violations.

Health-based Violations of maximum contaminant levels (MCLs) or maximum residual disinfectant levels (MRDLs), which specify the highest concentrations of contaminants or disinfectants, respectively, allowed in drinking water; or of treatment technique (TT) rules, which specify required processes intended to reduce the amounts of contaminants in drinking water. MCLs, MRDLs, and treatment technique rules are all health-based drinking water standards.
Maximum Contaminant Level or MCL The highest level of a contaminant that is allowed in drinking water. MCLs are set as close to the MCLGs as feasible using the best available treatment technology.
Treatment Technique A required process intended to reduce the level of a contaminant in drinking water.
Maximum residual disinfectant level or MRDL The highest level of a disinfectant allowed in drinking water. There is convincing evidence that addition of a disinfectant is necessary for control of microbial contaminants.
Monitoring & reporting Failure to conduct regular monitoring of drinking water quality, as required by SDWA, or to submit monitoring results in a timely fashion to the primacy agency or EPA.
Public notification & other Failure to provide notification to the public as required by the Violations of Public Notification Rule and the Consumer Confidence Report Rule, and violations of other requirements such as those violations related to variances and exemptions.

PWS Violation


Violations

Violation Category CodeViolation Type DescriptionRule NameContaminant NameViolation IDCompliance Status DescriptionCompliance Period Begin DateCompliance Period End DateIs Health Based Ind
MRLead Consumer NoticeLead and Copper RuleLead and Copper Rule1537Returned to Compliance31-MAR-2020 - No
MONMonitoring, Routine (RTCR)Revised Total Coliform RuleRevised Total Coliform Rule1508Returned to Compliance01-NOV-201730-NOV-2017No
MRMonitoring, Routine Minor (TCR)Total Coliform RuleColiform (TCR)1507Returned to Compliance01-APR-201030-APR-2010No
OtherConsumer Confidence Report Complete Failure to ReportConsumer Confidence RuleConsumer Confidence Rule299Returned to Compliance19-OCT-1999 - No
MRInitial Tap Sampling for Pb and CuLead and Copper RuleLead and Copper Rule194Returned to Compliance01-JAN-1994 - No
  • 1 - 5 of 5

Enforcement Actions


Enforcement Actions

Latest Enforcement IDAssociated To Violation IDEnforcement Action Type CodeEnforcement Action DescriptionEnforcement DateOriginator DescriptionEnforcement Comment
3081537SOXState Compliance achieved01-APR-2020Statesystem submitted LCN for 6M2020_1 samples. --DCS
3061508SIFState Public Notification received01-MAY-2018State -
3031507SIFState Public Notification received17-FEB-2011State -
298299SOXState Compliance achieved25-OCT-1999StateCOWLEY CO RWD #1-SOX
194194SOXState Compliance achieved02-NOV-1994State -
  • 1 - 5 of 5

PWS Facilities


All Facilities

Facility NameFacility IDIs SourceFacility Type DescriptionWater Type DescriptionAvailability DescriptionFacility Activity Status
WELL 041247YesWell Ground waterPermanentActive
WELL 031252YesWell Ground waterPermanentActive
WELL 051251YesWell Ground waterPermanentActive
WELL 071250YesWell Ground waterPermanentActive
WELL 061249YesWell Ground waterPermanentActive
DISTRIBUTION4854NoDistribution System/Zone - - Active
PUMP FACILITY8315NoPump Facility - - Active
SYSTEM LOCATION11479NoSampling Station - - Active
STORAGE TANK 017040NoStorage - - Active
TP0023542NoTreatment Plant - - Active
TP0013543NoTreatment Plant - - Active
  • 1 - 11 of 11

PWS Treatment Processes


Treatment Processes

Facility NameFacility IDTreatment ProcessTreatment Objective
TP0023542Gaseous Chlorination, PostDisinfection
TP0023542Inhibitor, PolyphosphateCorrosion control
TP0013543Gaseous Chlorination, PostDisinfection
TP0013543Inhibitor, PolyphosphateCorrosion control
  • 1 - 4 of 4

For more information on a Water System:
Ask the operators of your water system, contact your primacy agency or file a Freedom of Information Act (FOIA) request.
Drinking water in general: Find out more about your drinking water web site or call the Safe Drinking Water Hotline (1-800-426-4791). EPA has also prepared a table about various regulated drinking water contaminants.
Tools for accessing EPA drinking water data: Safe Drinking Water Information System (SDWIS) Federal Reporting Services and Drinking Water Performance and Results Report.
Research Data: As well as monitoring the levels of drinking water contaminants for which EPA has set standards, EPA, states, and water systems also carry out studies of contaminants that may need to be regulated in the future. For more information about these contaminants, please see the National Contaminant Occurrence Database.