U.S. flag

An official website of the United States government

Safe Drinking Water Information System (SDWIS) Federal Reporting Services

Your Drinking Water Query results from SDWIS Fed Reporting Services

PWS IDIN5221001
PWS NameCONNERSVILLE UTILITIES
PWS TypeCommunity water system
Owner TypeLocal government
Primary SourceGround water
Primacy TypeState
Is Wholesaler?No
Population Served13282
County ServedFayette

Note


The tables below list all violations that the state reported to EPA for this water system. Health-based violations are listed first, followed by treatment technique, MRDL, monitoring, reporting, and other violations.

Health-based Violations of maximum contaminant levels (MCLs) or maximum residual disinfectant levels (MRDLs), which specify the highest concentrations of contaminants or disinfectants, respectively, allowed in drinking water; or of treatment technique (TT) rules, which specify required processes intended to reduce the amounts of contaminants in drinking water. MCLs, MRDLs, and treatment technique rules are all health-based drinking water standards.
Maximum Contaminant Level or MCL The highest level of a contaminant that is allowed in drinking water. MCLs are set as close to the MCLGs as feasible using the best available treatment technology.
Treatment Technique A required process intended to reduce the level of a contaminant in drinking water.
Maximum residual disinfectant level or MRDL The highest level of a disinfectant allowed in drinking water. There is convincing evidence that addition of a disinfectant is necessary for control of microbial contaminants.
Monitoring & reporting Failure to conduct regular monitoring of drinking water quality, as required by SDWA, or to submit monitoring results in a timely fashion to the primacy agency or EPA.
Public notification & other Failure to provide notification to the public as required by the Violations of Public Notification Rule and the Consumer Confidence Report Rule, and violations of other requirements such as those violations related to variances and exemptions.

PWS Violation


Violations

Violation Category CodeViolation Type DescriptionRule NameContaminant NameViolation IDCompliance Status DescriptionCompliance Period Begin DateCompliance Period End DateIs Health Based Ind
MCLMaximum Contaminant Level Violation, Monthly (TCR)Total Coliform RuleColiform (TCR)102Returned to Compliance01-APR-200230-APR-2002Yes
MRMonitoring, RegularRadionuclides and Revised Rad RuleGross Alpha, Excl. Radon and U7008280Known30-JUN-198029-SEP-1980No
  • 1 - 2 of 2

Enforcement Actions


Enforcement Actions

PWS Facilities


All Facilities

Facility NameFacility IDIs SourceFacility Type DescriptionWater Type DescriptionAvailability DescriptionFacility Activity Status
WELL #418702YesWell Ground waterOtherInactive
WELL #15970YesWell Ground waterPermanentActive
WELL #638371YesWell Ground waterPermanentActive
WELL #1218706YesWell Ground waterPermanentActive
WELL #1118705YesWell Ground waterPermanentActive
WELL #1018704YesWell Ground waterPermanentActive
WELL #518703YesWell Ground waterPermanentActive
WELL #318701YesWell Ground waterPermanentActive
WELL #218700YesWell Ground waterPermanentActive
DISTRIBUTION SYSTEM13706NoDistribution System/Zone - - Active
PUMPING FACILITY33378NoPump Facility - - Active
STORAGE TANK #121501NoStorage - - Active
STORAGE TANK #221502NoStorage - - Active
STORAGE TANK #321503NoStorage - - Active
TREATMENT PLANT #221504NoTreatment Plant - - Active
TREATMENT PLANT #17252NoTreatment Plant - - Active
  • 1 - 16 of 16

PWS Treatment Processes


Treatment Processes

Facility NameFacility IDTreatment ProcessTreatment Objective
TREATMENT PLANT #221504Aeration, CascadeOrganics removal
TREATMENT PLANT #221504Gaseous Chlorination, PostDisinfection
TREATMENT PLANT #221504Filtration, Pressure SandParticulate removal
TREATMENT PLANT #17252Hypochlorination, PostDisinfection
TREATMENT PLANT #17252Hypochlorination, PreDisinfection
TREATMENT PLANT #17252Hypochlorination, PostDisinfection
TREATMENT PLANT #17252Gaseous Chlorination, PostDisinfection
TREATMENT PLANT #17252Aeration, CascadeOrganics removal
TREATMENT PLANT #17252Filtration, Pressure SandInorganics removal
TREATMENT PLANT #17252FluoridationOther
  • 1 - 10 of 10

For more information on a Water System:
Ask the operators of your water system, contact your primacy agency or file a Freedom of Information Act (FOIA) request.
Drinking water in general: Find out more about your drinking water web site or call the Safe Drinking Water Hotline (1-800-426-4791). EPA has also prepared a table about various regulated drinking water contaminants.
Tools for accessing EPA drinking water data: Safe Drinking Water Information System (SDWIS) Federal Reporting Services and Drinking Water Performance and Results Report.
Research Data: As well as monitoring the levels of drinking water contaminants for which EPA has set standards, EPA, states, and water systems also carry out studies of contaminants that may need to be regulated in the future. For more information about these contaminants, please see the National Contaminant Occurrence Database.