U.S. flag

An official website of the United States government

Safe Drinking Water Information System (SDWIS) Federal Reporting Services

Your Drinking Water Query results from SDWIS Fed Reporting Services

PWS IDIL1190500
PWS NameHARTFORD
PWS TypeCommunity water system
Owner TypeLocal government
Primary SourceGround water
Primacy TypeState
Is Wholesaler?No
Population Served1260
County ServedMadison

Note


The tables below list all violations that the state reported to EPA for this water system. Health-based violations are listed first, followed by treatment technique, MRDL, monitoring, reporting, and other violations.

Health-based Violations of maximum contaminant levels (MCLs) or maximum residual disinfectant levels (MRDLs), which specify the highest concentrations of contaminants or disinfectants, respectively, allowed in drinking water; or of treatment technique (TT) rules, which specify required processes intended to reduce the amounts of contaminants in drinking water. MCLs, MRDLs, and treatment technique rules are all health-based drinking water standards.
Maximum Contaminant Level or MCL The highest level of a contaminant that is allowed in drinking water. MCLs are set as close to the MCLGs as feasible using the best available treatment technology.
Treatment Technique A required process intended to reduce the level of a contaminant in drinking water.
Maximum residual disinfectant level or MRDL The highest level of a disinfectant allowed in drinking water. There is convincing evidence that addition of a disinfectant is necessary for control of microbial contaminants.
Monitoring & reporting Failure to conduct regular monitoring of drinking water quality, as required by SDWA, or to submit monitoring results in a timely fashion to the primacy agency or EPA.
Public notification & other Failure to provide notification to the public as required by the Violations of Public Notification Rule and the Consumer Confidence Report Rule, and violations of other requirements such as those violations related to variances and exemptions.

PWS Violation


Violations

Violation Category CodeViolation Type DescriptionRule NameContaminant NameViolation IDCompliance Status DescriptionCompliance Period Begin DateCompliance Period End DateIs Health Based Ind
MRMonitoring and Reporting (DBP)Stage 2 Disinfectants and Disinfection Byproducts RuleTTHM7057010Returned to Compliance01-JUL-202330-SEP-2023No
MRMonitoring and Reporting (DBP)Stage 2 Disinfectants and Disinfection Byproducts RuleTotal Haloacetic Acids (HAA5)7057011Returned to Compliance01-JUL-202330-SEP-2023No
OtherConsumer Confidence Report Complete Failure to ReportConsumer Confidence RuleConsumer Confidence Rule7057012Returned to Compliance01-JUL-2023 - No
OtherConsumer Confidence Report Inadequate ReportingConsumer Confidence RuleConsumer Confidence Rule7057008Returned to Compliance01-JUL-2018 - No
OtherConsumer Confidence Report Complete Failure to ReportConsumer Confidence RuleConsumer Confidence Rule7057007Returned to Compliance01-JUL-2018 - No
MCLMaximum Contaminant Level Violation, Monthly (TCR)Total Coliform RuleColiform (TCR)7056806Returned to Compliance01-APR-200630-APR-2006Yes
MCLMaximum Contaminant Level Violation, Monthly (TCR)Total Coliform RuleColiform (TCR)2650694Known01-SEP-199430-SEP-1994Yes
MRMonitoring, Routine Minor (TCR)Total Coliform RuleColiform (TCR)1830093Known01-APR-199330-APR-1993No
MRMonitoring, RegularRadionuclides and Revised Rad RuleGross Alpha, Excl. Radon and U7056280Known30-JUN-197729-JUN-1981No
  • 1 - 9 of 9

Enforcement Actions


Enforcement Actions

Latest Enforcement IDAssociated To Violation IDEnforcement Action Type CodeEnforcement Action DescriptionEnforcement DateOriginator DescriptionEnforcement Comment
39626177057010SIFState Public Notification received07-JUN-2024State -
39626177057011SIFState Public Notification received07-JUN-2024State -
39626157057012SOXState Compliance achieved05-JAN-2024State -
39626117057008SOXState Compliance achieved10-SEP-2018State -
39626087057007SIAState Violation/Reminder Notice21-AUG-2018State -
39626077056806SOXState Compliance achieved01-NOV-2006StateSUPPLY WITHOUT TCR VIOLATIONS FOR 6 MOS
39618952650694SIEState Public Notification requested26-NOV-1994State -
19719931830093SIEState Public Notification requested05-JUN-1993State -
  • 1 - 8 of 8

PWS Facilities


All Facilities

Facility NameFacility IDIs SourceFacility Type DescriptionWater Type DescriptionAvailability DescriptionFacility Activity Status
CC04 - BSTR STA ROXANA (ABANDONED)44028YesConsecutive ConnectionGround waterOtherInactive
WELL 4 (60106)22400YesWell Ground waterPermanentActive
WELL 3 (60105)22399YesWell Ground waterPermanentActive
WELL 2 (60104) ABANDONED22398YesWell Ground waterOtherInactive
WELL 1 (60103) ABANDONED22397YesWell Ground waterOtherInactive
CC03 - ROXANA MASTER METER26383YesConsecutive ConnectionGround waterPermanentActive
CC05 - MASTER METER 2 @ BOC44029YesConsecutive ConnectionGround waterPermanentActive
CC 04-BSTR STATION - ROXANA INTERCONNECT26384YesConsecutive ConnectionGround waterPermanentInactive
CC 05-MASTER METER 2 - AT BOC PLANT26385YesConsecutive ConnectionGround waterPermanentInactive
CW01 - CLEARWELL AT WTP44017NoClear Well - - Active
NORTHERN DISTRIBUTION SYSTEM24553NoDistribution System/Zone - - Active
DS2 - SOUTHERN ROXANA PRESSURE ZONE44019NoDistribution System/Zone - - Active
SCHOOL LEAD SAMPLING45086NoDistribution System/Zone - - Active
PF04 - ROXANA WATER BOOSTER PUMP STATION44018NoPump Facility - - Active
GENERIC FINISHED SAMPLING STATION28212NoSampling Station - - Active
GENERIC RAW SAMPLING STATION30634NoSampling Station - - Active
DISTRIBUTION ELEVATED STORAGE11532NoStorage - - Active
GR01 - GROUND TANK AT TP0112958NoStorage - - Active
GR04 - GROUND TANK AT PF0412959NoStorage - - Active
DISTRIBUTION GROUND STORAGE (INACTIVE)12334NoStorage - - Inactive
TP01 - 1972 WATER TREATMENT PLANT16671NoTreatment Plant - - Active
TP 02-OLD TREATMENT PLANT (ABANDONED)16672NoTreatment Plant - - Inactive
  • 1 - 22 of 22

PWS Treatment Processes


Treatment Processes

Facility NameFacility IDTreatment ProcessTreatment Objective
TP01 - 1972 WATER TREATMENT PLANT16671FluoridationOther
TP01 - 1972 WATER TREATMENT PLANT16671Filtration, Rapid SandInorganics removal
TP01 - 1972 WATER TREATMENT PLANT16671SedimentationSoftening (hardness removal)
TP01 - 1972 WATER TREATMENT PLANT16671Gaseous Chlorination, PostDisinfection
TP01 - 1972 WATER TREATMENT PLANT16671Aeration, CascadeIron removal
TP01 - 1972 WATER TREATMENT PLANT16671pH Adjustment, PreIron removal
TP01 - 1972 WATER TREATMENT PLANT16671Aeration, CascadeCorrosion control
TP01 - 1972 WATER TREATMENT PLANT16671pH Adjustment, PostCorrosion control
TP01 - 1972 WATER TREATMENT PLANT16671CoagulationSoftening (hardness removal)
TP01 - 1972 WATER TREATMENT PLANT16671Rapid MixSoftening (hardness removal)
TP01 - 1972 WATER TREATMENT PLANT16671pH Adjustment, PreSoftening (hardness removal)
  • 1 - 11 of 11

For more information on a Water System:
Ask the operators of your water system, contact your primacy agency or file a Freedom of Information Act (FOIA) request.
Drinking water in general: Find out more about your drinking water web site or call the Safe Drinking Water Hotline (1-800-426-4791). EPA has also prepared a table about various regulated drinking water contaminants.
Tools for accessing EPA drinking water data: Safe Drinking Water Information System (SDWIS) Federal Reporting Services and Drinking Water Performance and Results Report.
Research Data: As well as monitoring the levels of drinking water contaminants for which EPA has set standards, EPA, states, and water systems also carry out studies of contaminants that may need to be regulated in the future. For more information about these contaminants, please see the National Contaminant Occurrence Database.