U.S. flag

An official website of the United States government

Safe Drinking Water Information System (SDWIS) Federal Reporting Services

Your Drinking Water Query results from SDWIS Fed Reporting Services

PWS IDIL1110200
PWS NameFOX RIVER GROVE
PWS TypeCommunity water system
Owner TypeLocal government
Primary SourceGround water
Primacy TypeState
Is Wholesaler?No
Population Served4702
County ServedMcHenry

Note


The tables below list all violations that the state reported to EPA for this water system. Health-based violations are listed first, followed by treatment technique, MRDL, monitoring, reporting, and other violations.

Health-based Violations of maximum contaminant levels (MCLs) or maximum residual disinfectant levels (MRDLs), which specify the highest concentrations of contaminants or disinfectants, respectively, allowed in drinking water; or of treatment technique (TT) rules, which specify required processes intended to reduce the amounts of contaminants in drinking water. MCLs, MRDLs, and treatment technique rules are all health-based drinking water standards.
Maximum Contaminant Level or MCL The highest level of a contaminant that is allowed in drinking water. MCLs are set as close to the MCLGs as feasible using the best available treatment technology.
Treatment Technique A required process intended to reduce the level of a contaminant in drinking water.
Maximum residual disinfectant level or MRDL The highest level of a disinfectant allowed in drinking water. There is convincing evidence that addition of a disinfectant is necessary for control of microbial contaminants.
Monitoring & reporting Failure to conduct regular monitoring of drinking water quality, as required by SDWA, or to submit monitoring results in a timely fashion to the primacy agency or EPA.
Public notification & other Failure to provide notification to the public as required by the Violations of Public Notification Rule and the Consumer Confidence Report Rule, and violations of other requirements such as those violations related to variances and exemptions.

PWS Violation


Violations

Violation Category CodeViolation Type DescriptionRule NameContaminant NameViolation IDCompliance Status DescriptionCompliance Period Begin DateCompliance Period End DateIs Health Based Ind
TTWQP Entry Point/Tap Treatment Technique Non-ComplianceLead and Copper RuleLead and Copper Rule7146515Returned to Compliance01-JUL-202031-DEC-2020Yes
OtherConsumer Confidence Report Inadequate ReportingConsumer Confidence RuleConsumer Confidence Rule7146514Returned to Compliance01-JUL-2014 - No
MRLead Consumer NoticeLead and Copper RuleLead and Copper Rule7146510Returned to Compliance01-OCT-2009 - No
MRWater Quality Parameter M/RLead and Copper RuleLead and Copper Rule7146509Returned to Compliance01-JAN-200830-JUN-2008No
TTWQP Entry Point/Tap Treatment Technique Non-ComplianceLead and Copper RuleLead and Copper Rule7146406Returned to Compliance01-JAN-200630-JUN-2006Yes
MRMonitoring and Reporting (DBP)Stage 1 Disinfectants and Disinfection Byproducts RuleTotal Haloacetic Acids (HAA5)7146507Returned to Compliance01-JAN-200431-DEC-2006No
MCLMaximum Contaminant Level Violation, Monthly (TCR)Total Coliform RuleColiform (TCR)5217400Known01-JUL-200031-JUL-2000Yes
MRMonitoring, Routine Minor (TCR)Total Coliform RuleColiform (TCR)4209198Known01-JUL-199831-JUL-1998No
MRMonitoring, Routine Minor (TCR)Total Coliform RuleColiform (TCR)4054098Known01-MAR-199831-MAR-1998No
MRMonitoring, Routine Minor (TCR)Total Coliform RuleColiform (TCR)2646794Known01-AUG-199431-AUG-1994No
TTOCCT/SOWT Study/RecommendationLead and Copper RuleLead and Copper Rule1977393Returned to Compliance07-DEC-1992 - Yes
MCLMaximum Contaminant Level Violation, AverageVolatile Organic ChemicalsTrichloroethylene1478692Known01-JAN-199231-MAR-1992Yes
MCLMaximum Contaminant Level Violation, AverageVolatile Organic ChemicalsTrichloroethylene1407292Known01-OCT-199131-DEC-1991Yes
MCLMaximum Contaminant Level Violation, AverageVolatile Organic ChemicalsTrichloroethylene1478591Known01-JUL-199130-SEP-1991Yes
MCLMaximum Contaminant Level Violation, AverageVolatile Organic ChemicalsTrichloroethylene1407191Known01-APR-199130-JUN-1991Yes
MCLMaximum Contaminant Level Violation, AverageVolatile Organic ChemicalsTrichloroethylene1407091Known01-JAN-199131-MAR-1991Yes
MCLMaximum Contaminant Level Violation, AverageVolatile Organic ChemicalsTrichloroethylene1406991Known01-OCT-199031-DEC-1990Yes
MRMonitoring, RegularRadionuclides and Revised Rad RuleGross Alpha, Excl. Radon and U7144080Known30-JUN-197729-JUN-1981No
  • 1 - 18 of 18

Enforcement Actions


Enforcement Actions

Latest Enforcement IDAssociated To Violation IDEnforcement Action Type CodeEnforcement Action DescriptionEnforcement DateOriginator DescriptionEnforcement Comment
73666237146515SOXState Compliance achieved02-JUL-2021State -
73666177146514SOXState Compliance achieved08-JUN-2015State -
73666157146510SOXState Compliance achieved09-OCT-2009StateSent in LCRN example and Certification Form
73666137146509SOXState Compliance achieved17-JUL-2008StateReceived form
73666107146406SOXState Compliance achieved05-JUL-2007StateRequested change in ranges on approximately 8/7/2007. Request approved on 9/28/2007
73666077146507SOXState Compliance achieved26-OCT-2006State -
1804005217400SIEState Public Notification requested15-SEP-2000State -
73620984209198SIEState Public Notification requested15-SEP-1998State -
71997984054098SIEState Public Notification requested30-MAY-1998State -
39487952646794SIEState Public Notification requested29-OCT-1994State -
42046931977393SOXState Compliance achieved17-SEP-1993State -
1E921478591EFJFederal issued Formal Notice of Violation02-SEP-1992ODSWeb -
1E921407091EFJFederal issued Formal Notice of Violation02-SEP-1992ODSWeb -
1E921407292EFJFederal issued Formal Notice of Violation02-SEP-1992ODSWeb -
1E921407191EFJFederal issued Formal Notice of Violation02-SEP-1992ODSWeb -
15720921406991SIEState Public Notification requested07-MAY-1992State -
15730921478692SIEState Public Notification requested01-JAN-1992State -
  • 1 - 17 of 17

PWS Facilities


All Facilities

Facility NameFacility IDIs SourceFacility Type DescriptionWater Type DescriptionAvailability DescriptionFacility Activity Status
CC 03-EMERGENCY CONNECTION33986YesConsecutive ConnectionGround waterEmergencyActive
WELL 6 (02196)43845YesWell Ground waterPermanentActive
WELL 4 (01394)32614YesWell Ground waterPermanentActive
WELL 2 (20155)19870YesWell Ground waterPermanentActive
WELL 1 (20154)19869YesWell Ground waterPermanentActive
WELL 5 (02125) (SEALED)41384YesWell Ground waterOtherInactive
WELL 3 (00983) ABANDONED18786YesWell Ground waterOtherInactive
FOX RIVER GROVE24402NoDistribution System/Zone - - Active
SCHOOL LEAD SAMPLING45069NoDistribution System/Zone - - Active
CHILDCARE FACILITY LEAD SAMPLING45070NoDistribution System/Zone - - Active
GENERIC FINISHED SAMPLING STATION28061NoSampling Station - - Active
GENERIC RAW SAMPLING STATION30483NoSampling Station - - Active
ELEV1 - 0.5MG ELEVATED TANK11455NoStorage - - Active
TP 01-WELL #1 & #2 IRON REMOVAL PLANT16469NoTreatment Plant - - Active
TP 02-WELL #4 & #6 IRON REMOVAL PLANT16470NoTreatment Plant - - Active
  • 1 - 15 of 15

PWS Treatment Processes


Treatment Processes

Facility NameFacility IDTreatment ProcessTreatment Objective
TP 01-WELL #1 & #2 IRON REMOVAL PLANT16469FluoridationOther
TP 01-WELL #1 & #2 IRON REMOVAL PLANT16469Aeration, Slat TrayOrganics removal
TP 01-WELL #1 & #2 IRON REMOVAL PLANT16469Inhibitor, PolyphosphateCorrosion control
TP 01-WELL #1 & #2 IRON REMOVAL PLANT16469Gaseous Chlorination, PostDisinfection
TP 01-WELL #1 & #2 IRON REMOVAL PLANT16469Filtration, GreensandIron removal
TP 01-WELL #1 & #2 IRON REMOVAL PLANT16469Aeration, Slat TrayIron removal
TP 01-WELL #1 & #2 IRON REMOVAL PLANT16469Gaseous Chlorination, PreIron removal
TP 01-WELL #1 & #2 IRON REMOVAL PLANT16469PermanganateIron removal
TP 02-WELL #4 & #6 IRON REMOVAL PLANT16470FluoridationOther
TP 02-WELL #4 & #6 IRON REMOVAL PLANT16470Aeration, Slat TrayOrganics removal
TP 02-WELL #4 & #6 IRON REMOVAL PLANT16470Gaseous Chlorination, PreIron removal
TP 02-WELL #4 & #6 IRON REMOVAL PLANT16470Gaseous Chlorination, PostDisinfection
TP 02-WELL #4 & #6 IRON REMOVAL PLANT16470Filtration, GreensandIron removal
TP 02-WELL #4 & #6 IRON REMOVAL PLANT16470Aeration, Slat TrayIron removal
TP 02-WELL #4 & #6 IRON REMOVAL PLANT16470PermanganateIron removal
TP 02-WELL #4 & #6 IRON REMOVAL PLANT16470Inhibitor, PolyphosphateCorrosion control
  • 1 - 16 of 16

For more information on a Water System:
Ask the operators of your water system, contact your primacy agency or file a Freedom of Information Act (FOIA) request.
Drinking water in general: Find out more about your drinking water web site or call the Safe Drinking Water Hotline (1-800-426-4791). EPA has also prepared a table about various regulated drinking water contaminants.
Tools for accessing EPA drinking water data: Safe Drinking Water Information System (SDWIS) Federal Reporting Services and Drinking Water Performance and Results Report.
Research Data: As well as monitoring the levels of drinking water contaminants for which EPA has set standards, EPA, states, and water systems also carry out studies of contaminants that may need to be regulated in the future. For more information about these contaminants, please see the National Contaminant Occurrence Database.