U.S. flag

An official website of the United States government

Safe Drinking Water Information System (SDWIS) Federal Reporting Services

Your Drinking Water Query results from SDWIS Fed Reporting Services

PWS IDIL0975550
PWS NameFOX LAKE HILLS SUBDIVISION - LAKE CO PW
PWS TypeCommunity water system
Owner TypeLocal government
Primary SourceSurface water purchased
Primacy TypeState
Is Wholesaler?No
Population Served2628
County ServedLake

Note


The tables below list all violations that the state reported to EPA for this water system. Health-based violations are listed first, followed by treatment technique, MRDL, monitoring, reporting, and other violations.

Health-based Violations of maximum contaminant levels (MCLs) or maximum residual disinfectant levels (MRDLs), which specify the highest concentrations of contaminants or disinfectants, respectively, allowed in drinking water; or of treatment technique (TT) rules, which specify required processes intended to reduce the amounts of contaminants in drinking water. MCLs, MRDLs, and treatment technique rules are all health-based drinking water standards.
Maximum Contaminant Level or MCL The highest level of a contaminant that is allowed in drinking water. MCLs are set as close to the MCLGs as feasible using the best available treatment technology.
Treatment Technique A required process intended to reduce the level of a contaminant in drinking water.
Maximum residual disinfectant level or MRDL The highest level of a disinfectant allowed in drinking water. There is convincing evidence that addition of a disinfectant is necessary for control of microbial contaminants.
Monitoring & reporting Failure to conduct regular monitoring of drinking water quality, as required by SDWA, or to submit monitoring results in a timely fashion to the primacy agency or EPA.
Public notification & other Failure to provide notification to the public as required by the Violations of Public Notification Rule and the Consumer Confidence Report Rule, and violations of other requirements such as those violations related to variances and exemptions.

PWS Violation


Violations

Violation Category CodeViolation Type DescriptionRule NameContaminant NameViolation IDCompliance Status DescriptionCompliance Period Begin DateCompliance Period End DateIs Health Based Ind
MRMonitoring and Reporting (DBP)Stage 2 Disinfectants and Disinfection Byproducts RuleTTHM7044084Returned to Compliance01-JUL-202430-SEP-2024No
OtherConsumer Confidence Report Inadequate ReportingConsumer Confidence RuleConsumer Confidence Rule7044081Returned to Compliance01-JUL-2012 - No
MRMonitoring, RegularRadionuclides and Revised Rad RuleGross Alpha, Excl. Radon and U7044080Known30-JUN-197729-JUN-1981No
  • 1 - 3 of 3

Enforcement Actions


Enforcement Actions

Latest Enforcement IDAssociated To Violation IDEnforcement Action Type CodeEnforcement Action DescriptionEnforcement DateOriginator DescriptionEnforcement Comment
815027044084SIFState Public Notification received30-JUN-2025State -
814917044081SOXState Compliance achieved10-JUL-2013State -
  • 1 - 2 of 2

PWS Facilities


All Facilities

Facility NameFacility IDIs SourceFacility Type DescriptionWater Type DescriptionAvailability DescriptionFacility Activity Status
CC02-CLCJAWA WATER41587YesConsecutive ConnectionSurface waterPermanentActive
WL20009 - WELL 2 (ABANDONED)19726YesWell Ground waterOtherInactive
WL20008 - WELL 1 (EMERGENCY)19725YesWell Ground waterEmergencyActive
FOX LAKE HLS SBDV24225NoDistribution System/Zone - - Active
SCHOOL LEAD SAMPLING45555NoDistribution System/Zone - - Active
GENERIC FINISHED SAMPLING STATION27884NoSampling Station - - Active
GENERIC RAW SAMPLING STATION30306NoSampling Station - - Active
ELEV01-150K GALLON ELEVATED TANK11380NoStorage - - Active
DISTRIBUTION PRESSURE STORAGE13518NoStorage - - Inactive
TAP 01 PRESSURE STORAGE14160NoStorage - - Inactive
TAP 02 IRON FILTRATION14161NoStorage - - Inactive
TP 01-WELL 1 (EMERGENCY)16190NoTreatment Plant - - Active
TP 02-CLCJAWA WATER W/ NA HYPOCHLORITE16191NoTreatment Plant - - Active
  • 1 - 13 of 13

PWS Treatment Processes


Treatment Processes

Facility NameFacility IDTreatment ProcessTreatment Objective
TP 01-WELL 1 (EMERGENCY)16190Hypochlorination, PostDisinfection
TP 02-CLCJAWA WATER W/ NA HYPOCHLORITE16191Hypochlorination, PostDisinfection
  • 1 - 2 of 2

For more information on a Water System:
Ask the operators of your water system, contact your primacy agency or file a Freedom of Information Act (FOIA) request.
Drinking water in general: Find out more about your drinking water web site or call the Safe Drinking Water Hotline (1-800-426-4791). EPA has also prepared a table about various regulated drinking water contaminants.
Tools for accessing EPA drinking water data: Safe Drinking Water Information System (SDWIS) Federal Reporting Services and Drinking Water Performance and Results Report.
Research Data: As well as monitoring the levels of drinking water contaminants for which EPA has set standards, EPA, states, and water systems also carry out studies of contaminants that may need to be regulated in the future. For more information about these contaminants, please see the National Contaminant Occurrence Database.