PWS IDIL0890250
PWS NameEAST DUNDEE
PWS TypeCommunity water system
Owner TypeLocal government
Primary SourceGround water
Primacy TypeState
Is Wholesaler?No
Population Served3115
County ServedKane

Note


The tables below list all violations that the state reported to EPA for this water system. Health-based violations are listed first, followed by treatment technique, MRDL, monitoring, reporting, and other violations.

Health-based Violations of maximum contaminant levels (MCLs) or maximum residual disinfectant levels (MRDLs), which specify the highest concentrations of contaminants or disinfectants, respectively, allowed in drinking water; or of treatment technique (TT) rules, which specify required processes intended to reduce the amounts of contaminants in drinking water. MCLs, MRDLs, and treatment technique rules are all health-based drinking water standards.
Maximum Contaminant Level or MCL The highest level of a contaminant that is allowed in drinking water. MCLs are set as close to the MCLGs as feasible using the best available treatment technology.
Treatment Technique A required process intended to reduce the level of a contaminant in drinking water.
Maximum residual disinfectant level or MRDL The highest level of a disinfectant allowed in drinking water. There is convincing evidence that addition of a disinfectant is necessary for control of microbial contaminants.
Monitoring & reporting Failure to conduct regular monitoring of drinking water quality, as required by SDWA, or to submit monitoring results in a timely fashion to the primacy agency or EPA.
Public notification & other Failure to provide notification to the public as required by the Violations of Public Notification Rule and the Consumer Confidence Report Rule, and violations of other requirements such as those violations related to variances and exemptions.

PWS Violation


Violations

  • 1 - 1 of 1

Enforcement Actions


Enforcement Actions

No enforcement action(s) found. EPA has no record of enforcement action(s) reported by the primacy agency for this water system.

PWS Facilities


All Facilities

Facility NameFacility IDIs SourceFacility Type DescriptionWater Type DescriptionAvailability DescriptionFacility Activity Status
CC 04-RECHLORINATION 0.5 MG ELEV TANK32257YesConsecutive ConnectionGround waterPermanentInactive
WELL 6 (01830)35062YesWell Ground waterPermanentActive
WELL 5 (01829)35061YesWell Ground waterPermanentActive
WELL 2 (20033) SEALED19750YesWell Ground waterOtherInactive
WELL (20032)19749YesWell Ground waterOtherInactive
WELL 3 (20034) EMERGENCY19751YesWell Ground waterEmergencyActive
WELL 4 (01089) EMERGENCY18885YesWell Ground waterEmergencyActive
EAST DUNDEE24012NoDistribution System/Zone - - Active
SCHOOL LEAD SAMPLING45276NoDistribution System/Zone - - Active
CHILDCARE FACILITY LEAD SAMPLING45277NoDistribution System/Zone - - Active
GENERIC FINISHED SAMPLING STATION27671NoSampling Station - - Active
GENERIC RAW SAMPLING STATION30093NoSampling Station - - Active
WATER QUALITY SAMPLING45515NoSampling Station - - Active
ELEV01-500K GALLON TOWER ON ROUTE 6811297NoStorage - - Active
SP01-70K GALLON STANDPIPE AT TP0214389NoStorage - - Active
ELEV02-500K GALLON TOWER ON ROUTE 2544806NoStorage - - Active
DISTRIBUTION GROUND STORAGE12230NoStorage - - Inactive
TAP 01 GROUND STORAGE12849NoStorage - - Inactive
TP02 -GROUND STORAGE35415NoStorage - - Inactive
TP 02-WELL 3 (EMERGENCY)15761NoTreatment Plant - - Active
TP 03-WELL 4 (EMERGENCY)15762NoTreatment Plant - - Active
TP 04-RECHLORINATION RT. 25 TOWER31801NoTreatment Plant - - Active
TP06-WELLS #5 & #6 FE FILTER & ION-EXCHA40662NoTreatment Plant - - Active
TP05 -- RECHLORINATION RT 68 TOWER15759NoTreatment Plant - - Inactive
TP 01-WELL 215760NoTreatment Plant - - Inactive
  • 1 - 25 of 25

PWS Treatment Processes


Treatment Processes

Facility NameFacility IDTreatment ProcessTreatment Objective
TP05 -- RECHLORINATION RT 68 TOWER15759Hypochlorination, PostDisinfection
TP 01-WELL 215760SequestrationInorganics removal
TP 02-WELL 3 (EMERGENCY)15761Gaseous Chlorination, PreDisinfection
TP 02-WELL 3 (EMERGENCY)15761SequestrationIron removal
TP 03-WELL 4 (EMERGENCY)15762Gaseous Chlorination, PreDisinfection
TP 03-WELL 4 (EMERGENCY)15762SequestrationIron removal
TP 04-RECHLORINATION RT. 25 TOWER31801Hypochlorination, PostDisinfection
TP06-WELLS #5 & #6 FE FILTER & ION-EXCHA40662Filtration, Pressure SandIron removal
TP06-WELLS #5 & #6 FE FILTER & ION-EXCHA40662Ion ExchangeRadionuclides removal
TP06-WELLS #5 & #6 FE FILTER & ION-EXCHA40662Inhibitor, PolyphosphateCorrosion control
TP06-WELLS #5 & #6 FE FILTER & ION-EXCHA40662FluoridationOther
TP06-WELLS #5 & #6 FE FILTER & ION-EXCHA40662Gaseous Chlorination, PostDisinfection
TP06-WELLS #5 & #6 FE FILTER & ION-EXCHA40662PermanganateIron removal
TP06-WELLS #5 & #6 FE FILTER & ION-EXCHA40662Aeration, DiffusedIron removal
  • 1 - 14 of 14

For more information on a Water System:
Ask the operators of your water system, contact your primacy agency or file a Freedom of Information Act (FOIA) request.
Drinking water in general: Find out more about your drinking water web site or call the Safe Drinking Water Hotline (1-800-426-4791). EPA has also prepared a table about various regulated drinking water contaminants.
Tools for accessing EPA drinking water data: Safe Drinking Water Information System (SDWIS) Federal Reporting Services and Drinking Water Performance and Results Report.
Research Data: As well as monitoring the levels of drinking water contaminants for which EPA has set standards, EPA, states, and water systems also carry out studies of contaminants that may need to be regulated in the future. For more information about these contaminants, please see the National Contaminant Occurrence Database.