U.S. flag

An official website of the United States government

Safe Drinking Water Information System (SDWIS) Federal Reporting Services

Your Drinking Water Query results from SDWIS Fed Reporting Services

PWS IDFL6600330
PWS NameWEBSTER, CITY OF (2 WPS)
PWS TypeCommunity water system
Owner TypeLocal government
Primary SourceGround water
Primacy TypeState
Is Wholesaler?No
Population Served800
County ServedSumter

Note


The tables below list all violations that the state reported to EPA for this water system. Health-based violations are listed first, followed by treatment technique, MRDL, monitoring, reporting, and other violations.

Health-based Violations of maximum contaminant levels (MCLs) or maximum residual disinfectant levels (MRDLs), which specify the highest concentrations of contaminants or disinfectants, respectively, allowed in drinking water; or of treatment technique (TT) rules, which specify required processes intended to reduce the amounts of contaminants in drinking water. MCLs, MRDLs, and treatment technique rules are all health-based drinking water standards.
Maximum Contaminant Level or MCL The highest level of a contaminant that is allowed in drinking water. MCLs are set as close to the MCLGs as feasible using the best available treatment technology.
Treatment Technique A required process intended to reduce the level of a contaminant in drinking water.
Maximum residual disinfectant level or MRDL The highest level of a disinfectant allowed in drinking water. There is convincing evidence that addition of a disinfectant is necessary for control of microbial contaminants.
Monitoring & reporting Failure to conduct regular monitoring of drinking water quality, as required by SDWA, or to submit monitoring results in a timely fashion to the primacy agency or EPA.
Public notification & other Failure to provide notification to the public as required by the Violations of Public Notification Rule and the Consumer Confidence Report Rule, and violations of other requirements such as those violations related to variances and exemptions.

PWS Violation


Violations

Violation Category CodeViolation Type DescriptionRule NameContaminant NameViolation IDCompliance Status DescriptionCompliance Period Begin DateCompliance Period End DateIs Health Based Ind
OtherConsumer Confidence Report Complete Failure to ReportConsumer Confidence RuleConsumer Confidence Rule20140003962Returned to Compliance01-JUL-2014 - No
MRFailure to Conduct Assessment MonitoringGround Water RuleE. COLI20110005216Known01-SEP-201130-SEP-2011No
MCLMaximum Contaminant Level Violation, Monthly (TCR)Total Coliform RuleColiform (TCR)20110005250Known01-SEP-201130-SEP-2011Yes
MRMonitoring, RegularNitrate RuleNitrate0302480Known01-JAN-200231-DEC-2002No
MRMonitoring, RegularNitrate RuleNitrate20030002480Known01-JAN-200231-DEC-2002No
MRMonitoring, RegularInorganic ChemicalsCadmium8970003Known01-MAR-198628-FEB-1989No
MRMonitoring, RegularInorganic ChemicalsBarium8970002Known01-MAR-198628-FEB-1989No
MRMonitoring, RegularInorganic ChemicalsMercury8970007Known01-MAR-198628-FEB-1989No
MRMonitoring, RegularNitrate RuleNitrate8970008Known01-MAR-198628-FEB-1989No
MRMonitoring, RegularInorganic ChemicalsSelenium8970009Known01-MAR-198628-FEB-1989No
MRMonitoring, RegularInorganic ChemicalsChromium8970004Known01-MAR-198628-FEB-1989No
MRMonitoring, RegularArsenic RuleArsenic8970001Known01-MAR-198628-FEB-1989No
MRMonitoring, RegularInorganic ChemicalsFluoride8970005Known01-MAR-198628-FEB-1989No
MRMonitoring, RegularSynthetic Organic Chemicals2,4,5-TP88V0002Known01-OCT-198430-SEP-1987No
MRMonitoring, RegularSynthetic Organic Chemicals2,4-D88V0003Known01-OCT-198430-SEP-1987No
MRMonitoring, RegularSynthetic Organic ChemicalsToxaphene88V0004Known01-OCT-198430-SEP-1987No
MRMonitoring, RegularSynthetic Organic ChemicalsMethoxychlor88V0005Known01-OCT-198430-SEP-1987No
MRMonitoring, RegularSynthetic Organic ChemicalsBHC-GAMMA88V0006Known01-OCT-198430-SEP-1987No
MRMonitoring, RegularSynthetic Organic ChemicalsEndrin88V0007Known01-OCT-198430-SEP-1987No
MRMonitoring, RegularRadionuclides and Revised Rad RuleGross Alpha, Excl. Radon and U88V0001Known01-APR-198431-MAR-1988No
  • 1 - 20 of 20

Enforcement Actions


Enforcement Actions

Latest Enforcement IDAssociated To Violation IDEnforcement Action Type CodeEnforcement Action DescriptionEnforcement DateOriginator DescriptionEnforcement Comment
45228520140003962SOXState Compliance achieved18-JUL-2014State -
33470620110005250SIFState Public Notification received26-OCT-2011State -
33470620110005216SIFState Public Notification received26-OCT-2011State -
88E00028970002SO8State Other20-APR-1988State -
88E00028970001SO8State Other20-APR-1988State -
88E00028970003SO8State Other20-APR-1988State -
88E00028970004SO8State Other20-APR-1988State -
88E00028970005SO8State Other20-APR-1988State -
88E00028970007SO8State Other20-APR-1988State -
88E00028970008SO8State Other20-APR-1988State -
88E00028970009SO8State Other20-APR-1988State -
88E000188V0001SO8State Other22-DEC-1987State -
  • 1 - 12 of 12

PWS Facilities


All Facilities

Facility NameFacility IDIs SourceFacility Type DescriptionWater Type DescriptionAvailability DescriptionFacility Activity Status
WELL # 21878317663YesWell Ground waterPermanentActive
NORTH WTP WELL NO. 114359754604YesWell Ground waterPermanentActive
STANDBY #14359750033YesWell Ground waterPermanentActive
WELL # 61878517665YesWell Ground waterPermanentActive
WELL # 71878417664YesWell Ground waterPermanentActive
CITY OF WEBSTER PLANT # 1159646600330NoTreatment Plant - - Active
CITY OF WEBSTER PLANT # 2-EAST159656600330NoTreatment Plant - - Active
CITY OF WEBSTER #3- WELL7/SOUT159666600330NoTreatment Plant - - Active
CITY OF WEBSTER PLANT 4-WELL6159676600330NoTreatment Plant - - Active
  • 1 - 9 of 9

PWS Treatment Processes


Treatment Processes

Facility NameFacility IDTreatment ProcessTreatment Objective
CITY OF WEBSTER PLANT # 1159646600330Gaseous Chlorination, PostDisinfection
CITY OF WEBSTER PLANT # 2-EAST159656600330Gaseous Chlorination, PostDisinfection
CITY OF WEBSTER PLANT # 2-EAST159656600330SequestrationOther
CITY OF WEBSTER #3- WELL7/SOUT159666600330Gaseous Chlorination, PostDisinfection
CITY OF WEBSTER #3- WELL7/SOUT159666600330SequestrationOther
CITY OF WEBSTER PLANT 4-WELL6159676600330Gaseous Chlorination, PostDisinfection
CITY OF WEBSTER PLANT 4-WELL6159676600330SequestrationOther
  • 1 - 7 of 7

For more information on a Water System:
Ask the operators of your water system, contact your primacy agency or file a Freedom of Information Act (FOIA) request.
Drinking water in general: Find out more about your drinking water web site or call the Safe Drinking Water Hotline (1-800-426-4791). EPA has also prepared a table about various regulated drinking water contaminants.
Tools for accessing EPA drinking water data: Safe Drinking Water Information System (SDWIS) Federal Reporting Services and Drinking Water Performance and Results Report.
Research Data: As well as monitoring the levels of drinking water contaminants for which EPA has set standards, EPA, states, and water systems also carry out studies of contaminants that may need to be regulated in the future. For more information about these contaminants, please see the National Contaminant Occurrence Database.