U.S. flag

An official website of the United States government

Safe Drinking Water Information System (SDWIS) Federal Reporting Services

Your Drinking Water Query results from SDWIS Fed Reporting Services

PWS IDFL6382055
PWS NameWILLISTON WTP
PWS TypeCommunity water system
Owner TypeLocal government
Primary SourceGround water
Primacy TypeState
Is Wholesaler?No
Population Served2400
County ServedLevy

Note


The tables below list all violations that the state reported to EPA for this water system. Health-based violations are listed first, followed by treatment technique, MRDL, monitoring, reporting, and other violations.

Health-based Violations of maximum contaminant levels (MCLs) or maximum residual disinfectant levels (MRDLs), which specify the highest concentrations of contaminants or disinfectants, respectively, allowed in drinking water; or of treatment technique (TT) rules, which specify required processes intended to reduce the amounts of contaminants in drinking water. MCLs, MRDLs, and treatment technique rules are all health-based drinking water standards.
Maximum Contaminant Level or MCL The highest level of a contaminant that is allowed in drinking water. MCLs are set as close to the MCLGs as feasible using the best available treatment technology.
Treatment Technique A required process intended to reduce the level of a contaminant in drinking water.
Maximum residual disinfectant level or MRDL The highest level of a disinfectant allowed in drinking water. There is convincing evidence that addition of a disinfectant is necessary for control of microbial contaminants.
Monitoring & reporting Failure to conduct regular monitoring of drinking water quality, as required by SDWA, or to submit monitoring results in a timely fashion to the primacy agency or EPA.
Public notification & other Failure to provide notification to the public as required by the Violations of Public Notification Rule and the Consumer Confidence Report Rule, and violations of other requirements such as those violations related to variances and exemptions.

PWS Violation


Violations

Violation Category CodeViolation Type DescriptionRule NameContaminant NameViolation IDCompliance Status DescriptionCompliance Period Begin DateCompliance Period End DateIs Health Based Ind
MRMonitoring and Reporting (DBP)Stage 2 Disinfectants and Disinfection Byproducts RuleTotal Haloacetic Acids (HAA5)20230014414Returned to Compliance01-JUL-202330-SEP-2023No
MRMonitoring and Reporting (DBP)Stage 2 Disinfectants and Disinfection Byproducts RuleTTHM20230014413Returned to Compliance01-JUL-202330-SEP-2023No
MRMonitoring and Reporting (DBP)Stage 2 Disinfectants and Disinfection Byproducts RuleTotal Haloacetic Acids (HAA5)20220015742Returned to Compliance01-JAN-202231-DEC-2022No
OtherConsumer Confidence Report Inadequate ReportingConsumer Confidence RuleConsumer Confidence Rule20210010743Returned to Compliance01-JUL-2021 - No
MONMonitoring, Routine (RTCR)Revised Total Coliform RuleRevised Total Coliform Rule20200009041Returned to Compliance01-JUL-202031-JUL-2020No
MRFailure to Conduct Assessment MonitoringGround Water RuleE. COLI20200009043Returned to Compliance01-JUL-202031-JUL-2020No
MRMonitoring, RegularNitrate RuleNitrate20160001755Returned to Compliance01-JAN-201531-DEC-2015No
MRMonitoring and Reporting (DBP)Stage 1 Disinfectants and Disinfection Byproducts RuleTTHM20120005235Known01-JUL-201230-SEP-2012No
MRMonitoring and Reporting (DBP)Stage 1 Disinfectants and Disinfection Byproducts RuleTotal Haloacetic Acids (HAA5)20120005259Known01-JUL-201230-SEP-2012No
MCLMaximum Contaminant Level Violation, Single SampleRadionuclides and Revised Rad RuleGross Alpha, Excl. Radon and U92V0001Known01-MAY-199230-APR-1996Yes
MCLMaximum Contaminant Level Violation, Single SampleInorganic ChemicalsMercury91V0012Known01-SEP-199131-AUG-1994Yes
  • 1 - 11 of 11

Enforcement Actions


Enforcement Actions

Latest Enforcement IDAssociated To Violation IDEnforcement Action Type CodeEnforcement Action DescriptionEnforcement DateOriginator DescriptionEnforcement Comment
63994820230014413SOXState Compliance achieved29-SEP-2023State -
63994820230014414SOXState Compliance achieved29-SEP-2023State -
63181520220015742SOXState Compliance achieved04-JAN-2023State -
59595020210010743SOXState Compliance achieved27-DEC-2021State -
56607120200009041SOXState Compliance achieved25-AUG-2020State -
56607120200009043SOXState Compliance achieved25-AUG-2020State -
45062720160001755SOXState Compliance achieved22-JAN-2016State -
36278920120005259SIAState Violation/Reminder Notice14-JAN-2013State -
36278920120005235SIAState Violation/Reminder Notice14-JAN-2013State -
95E000192V0001SIAState Violation/Reminder Notice31-JAN-1995State -
93E000191V0012SICState Technical Assistance Visit22-OCT-1992State -
  • 1 - 11 of 11

PWS Facilities


All Facilities

Facility NameFacility IDIs SourceFacility Type DescriptionWater Type DescriptionAvailability DescriptionFacility Activity Status
WTP1 WELL #11481214130YesWell Ground waterPermanentActive
AIRPORT/WTP4 WELL #24359753642YesWell Ground waterPermanentActive
AIRPORT WELL #14359753641YesWell Ground waterPermanentActive
WELL 14359753640YesWell Ground waterPermanentActive
WELL 14359753639YesWell Ground waterPermanentActive
WELL 14359753638YesWell Ground waterPermanentActive
WTP3 WELL #14359752384YesWell Ground waterPermanentActive
WTP2 WELL #14359751225YesWell Ground waterPermanentActive
WELL4359747532YesWell Ground waterPermanentActive
WELLS #1 #21481314130YesWell Ground waterPermanentActive
WILLISTON WTP #1127036382055NoTreatment Plant - - Active
WILLISTON WTP #2250126382055NoTreatment Plant - - Active
WILLISTON WTP #3400576382055NoTreatment Plant - - Active
WILLISTON WTP #4478576382055NoTreatment Plant - - Active
  • 1 - 14 of 14

PWS Treatment Processes


Treatment Processes

Facility NameFacility IDTreatment ProcessTreatment Objective
WILLISTON WTP #1127036382055Gaseous Chlorination, PostDisinfection
WILLISTON WTP #1127036382055Hypochlorination, PostDisinfection
WILLISTON WTP #2250126382055Gaseous Chlorination, PostDisinfection
WILLISTON WTP #2250126382055Hypochlorination, PostDisinfection
WILLISTON WTP #3400576382055Hypochlorination, PostDisinfection
WILLISTON WTP #4478576382055Hypochlorination, PostDisinfection
  • 1 - 6 of 6

For more information on a Water System:
Ask the operators of your water system, contact your primacy agency or file a Freedom of Information Act (FOIA) request.
Drinking water in general: Find out more about your drinking water web site or call the Safe Drinking Water Hotline (1-800-426-4791). EPA has also prepared a table about various regulated drinking water contaminants.
Tools for accessing EPA drinking water data: Safe Drinking Water Information System (SDWIS) Federal Reporting Services and Drinking Water Performance and Results Report.
Research Data: As well as monitoring the levels of drinking water contaminants for which EPA has set standards, EPA, states, and water systems also carry out studies of contaminants that may need to be regulated in the future. For more information about these contaminants, please see the National Contaminant Occurrence Database.