U.S. flag

An official website of the United States government

Safe Drinking Water Information System (SDWIS) Federal Reporting Services

Your Drinking Water Query results from SDWIS Fed Reporting Services

PWS IDFL6142734
PWS NamePEACE RIVER REG WATER PLANT
PWS TypeCommunity water system
Owner TypePublic/Private
Primary SourceSurface water
Primacy TypeState
Is Wholesaler?Yes
Population Served3301
County ServedDeSoto

Note


The tables below list all violations that the state reported to EPA for this water system. Health-based violations are listed first, followed by treatment technique, MRDL, monitoring, reporting, and other violations.

Health-based Violations of maximum contaminant levels (MCLs) or maximum residual disinfectant levels (MRDLs), which specify the highest concentrations of contaminants or disinfectants, respectively, allowed in drinking water; or of treatment technique (TT) rules, which specify required processes intended to reduce the amounts of contaminants in drinking water. MCLs, MRDLs, and treatment technique rules are all health-based drinking water standards.
Maximum Contaminant Level or MCL The highest level of a contaminant that is allowed in drinking water. MCLs are set as close to the MCLGs as feasible using the best available treatment technology.
Treatment Technique A required process intended to reduce the level of a contaminant in drinking water.
Maximum residual disinfectant level or MRDL The highest level of a disinfectant allowed in drinking water. There is convincing evidence that addition of a disinfectant is necessary for control of microbial contaminants.
Monitoring & reporting Failure to conduct regular monitoring of drinking water quality, as required by SDWA, or to submit monitoring results in a timely fashion to the primacy agency or EPA.
Public notification & other Failure to provide notification to the public as required by the Violations of Public Notification Rule and the Consumer Confidence Report Rule, and violations of other requirements such as those violations related to variances and exemptions.

PWS Violation


Violations

Violation Category CodeViolation Type DescriptionRule NameContaminant NameViolation IDCompliance Status DescriptionCompliance Period Begin DateCompliance Period End DateIs Health Based Ind
MRMonitoring and Reporting (DBP)Stage 2 Disinfectants and Disinfection Byproducts RuleTTHM20240001347Returned to Compliance01-OCT-202331-DEC-2023No
MRMonitoring and Reporting (DBP)Stage 2 Disinfectants and Disinfection Byproducts RuleTotal Haloacetic Acids (HAA5)20240001488Returned to Compliance01-OCT-202331-DEC-2023No
MRMonitoring and Reporting (DBP)Stage 2 Disinfectants and Disinfection Byproducts RuleTTHM20230014762Returned to Compliance01-JUL-202330-SEP-2023No
MRMonitoring and Reporting (DBP)Stage 2 Disinfectants and Disinfection Byproducts RuleTotal Haloacetic Acids (HAA5)20230014548Returned to Compliance01-JUL-202330-SEP-2023No
MRMonitoring, Routine Minor (TCR)Total Coliform RuleColiform (TCR)91V0001Known01-SEP-199130-SEP-1991No
  • 1 - 5 of 5

Enforcement Actions


Enforcement Actions

Latest Enforcement IDAssociated To Violation IDEnforcement Action Type CodeEnforcement Action DescriptionEnforcement DateOriginator DescriptionEnforcement Comment
63788020230014548SOXState Compliance achieved02-APR-2024State -
63787920240001488SOXState Compliance achieved02-APR-2024State -
63787920240001347SOXState Compliance achieved02-APR-2024State -
63788020230014762SOXState Compliance achieved02-APR-2024State -
  • 1 - 4 of 4

PWS Facilities


All Facilities

Facility NameFacility IDIs SourceFacility Type DescriptionWater Type DescriptionAvailability DescriptionFacility Activity Status
PEACE RIVER1168620YesIntakeSurface waterPermanentActive
ASR WF 2, WELL S-204359753077YesWell Ground waterPermanentActive
ASR WF 2, WELL S-194359753076YesWell Ground waterPermanentActive
ASR WF 2, WELL S-184359753075YesWell Ground waterPermanentActive
ASR WF 2, WELL S-174359753074YesWell Ground waterPermanentActive
ASR WF 2, WELL S-164359753073YesWell Ground waterPermanentActive
ASR WF 2, WELL S-154359753072YesWell Ground waterPermanentActive
ASR WF 2, WELL S-144359753071YesWell Ground waterPermanentActive
ASR WF 2, WELL S-134359753070YesWell Ground waterPermanentActive
ASR WF 2, WELL S-124359753069YesWell Ground waterPermanentActive
ASR WF 2, WELLS-114359753068YesWell Ground waterPermanentActive
ASR WF 2, WELL S-104359753067YesWell Ground waterPermanentActive
ASR WF 2, WELL S-44359753066YesWell Ground waterPermanentActive
ASR WF 1, WELL S-9R4359753065YesWell Ground waterPermanentActive
ASR WF 1, WELL S-5R4359753064YesWell Ground waterPermanentActive
ASR WF 1, WELL S-3R4359753063YesWell Ground waterPermanentActive
ASR WF 1, WELL S-74359753061YesWell Ground waterPermanentActive
ASR WF 1, WELL S-64359753060YesWell Ground waterPermanentActive
ASR WF 1, WELL S-24359753059YesWell Ground waterPermanentActive
ASR WF 1, WELL S-14359753058YesWell Ground waterPermanentActive
ASR WF 1, WELL T-14359753057YesWell Ground waterPermanentActive
ASR WF 1, WELL S-84359753062YesWell Ground waterOtherActive
SURFACE WATER PLANT104836142734NoTreatment Plant - - Active
DESOTO SOUTH BOOSTER STATION619176142734NoTreatment Plant - - Active
PG1A BOOSTER PLANT620376142734NoTreatment Plant - - Active
  • 1 - 25 of 25

PWS Treatment Processes


Treatment Processes

Facility NameFacility IDTreatment ProcessTreatment Objective
SURFACE WATER PLANT104836142734Gaseous Chlorination, PostDisinfection
SURFACE WATER PLANT104836142734Hypochlorination, PostDisinfection
SURFACE WATER PLANT104836142734ChloraminesDisinfection
SURFACE WATER PLANT104836142734CoagulationParticulate removal
SURFACE WATER PLANT104836142734FlocculationParticulate removal
SURFACE WATER PLANT104836142734SedimentationParticulate removal
SURFACE WATER PLANT104836142734Filtration, Rapid SandParticulate removal
SURFACE WATER PLANT104836142734pH AdjustmentCorrosion control
SURFACE WATER PLANT104836142734Activated Carbon, PowderedOther
SURFACE WATER PLANT104836142734PermanganateOther
DESOTO SOUTH BOOSTER STATION619176142734Hypochlorination, PostDisinfection
DESOTO SOUTH BOOSTER STATION619176142734ChloraminesDisinfection
PG1A BOOSTER PLANT620376142734Hypochlorination, PostDisinfection
PG1A BOOSTER PLANT620376142734ChloraminesDisinfection
  • 1 - 14 of 14

For more information on a Water System:
Ask the operators of your water system, contact your primacy agency or file a Freedom of Information Act (FOIA) request.
Drinking water in general: Find out more about your drinking water web site or call the Safe Drinking Water Hotline (1-800-426-4791). EPA has also prepared a table about various regulated drinking water contaminants.
Tools for accessing EPA drinking water data: Safe Drinking Water Information System (SDWIS) Federal Reporting Services and Drinking Water Performance and Results Report.
Research Data: As well as monitoring the levels of drinking water contaminants for which EPA has set standards, EPA, states, and water systems also carry out studies of contaminants that may need to be regulated in the future. For more information about these contaminants, please see the National Contaminant Occurrence Database.