U.S. flag

An official website of the United States government

Safe Drinking Water Information System (SDWIS) Federal Reporting Services

Your Drinking Water Query results from SDWIS Fed Reporting Services

PWS IDCT1220011
PWS NameAQUARION-SALISBURY
PWS TypeCommunity water system
Owner TypePrivate
Primary SourceSurface water
Primacy TypeState
Is Wholesaler?No
Population Served1932
County ServedLitchfield

Note


The tables below list all violations that the state reported to EPA for this water system. Health-based violations are listed first, followed by treatment technique, MRDL, monitoring, reporting, and other violations.

Health-based Violations of maximum contaminant levels (MCLs) or maximum residual disinfectant levels (MRDLs), which specify the highest concentrations of contaminants or disinfectants, respectively, allowed in drinking water; or of treatment technique (TT) rules, which specify required processes intended to reduce the amounts of contaminants in drinking water. MCLs, MRDLs, and treatment technique rules are all health-based drinking water standards.
Maximum Contaminant Level or MCL The highest level of a contaminant that is allowed in drinking water. MCLs are set as close to the MCLGs as feasible using the best available treatment technology.
Treatment Technique A required process intended to reduce the level of a contaminant in drinking water.
Maximum residual disinfectant level or MRDL The highest level of a disinfectant allowed in drinking water. There is convincing evidence that addition of a disinfectant is necessary for control of microbial contaminants.
Monitoring & reporting Failure to conduct regular monitoring of drinking water quality, as required by SDWA, or to submit monitoring results in a timely fashion to the primacy agency or EPA.
Public notification & other Failure to provide notification to the public as required by the Violations of Public Notification Rule and the Consumer Confidence Report Rule, and violations of other requirements such as those violations related to variances and exemptions.

PWS Violation


Violations

Violation Category CodeViolation Type DescriptionRule NameContaminant NameViolation IDCompliance Status DescriptionCompliance Period Begin DateCompliance Period End DateIs Health Based Ind
MRLead Consumer NoticeLead and Copper RuleLead and Copper Rule8949862Returned to Compliance30-DEC-2021 - No
OtherPublic Notification Violation for NPDWR ViolationPublic Notice Rule and Revised PN RulePublic Notice8949860Returned to Compliance15-SEP-2019 - No
OtherConsumer Confidence Report Complete Failure to ReportConsumer Confidence RuleConsumer Confidence Rule8949858Returned to Compliance01-JUL-2018 - No
MRMonitoring and Reporting (DBP)Stage 1 Disinfectants and Disinfection Byproducts RuleCARBON, TOTAL8949856Known01-APR-201830-JUN-2018No
MRMonitoring, RegularInorganic ChemicalsAsbestos8949861Known01-JAN-201231-DEC-2020No
OtherConsumer Confidence Report Complete Failure to ReportConsumer Confidence RuleConsumer Confidence Rule8948906Returned to Compliance01-JUL-2006 - No
TTFailure to Filter (SWTR)Surface Water Treatment RuleSurface Water Treatment Rule8943793Returned to Compliance01-JAN-1992 - Yes
TTFailure to Filter (SWTR)Surface Water Treatment RuleSurface Water Treatment Rule9999997Known01-JAN-199214-NOV-1996Yes
  • 1 - 8 of 8

Enforcement Actions


Enforcement Actions

Latest Enforcement IDAssociated To Violation IDEnforcement Action Type CodeEnforcement Action DescriptionEnforcement DateOriginator DescriptionEnforcement Comment
11117008949862SOXState Compliance achieved21-JAN-2022StateLead Consumer Notice received
11116998949861SIFState Public Notification received15-SEP-2021State -
11116968949860SOXState Compliance achieved23-OCT-2019StateCertification sent in prior to issuing violation letter. The certification document was late and this is a reporting violation.
11116958949856SIFState Public Notification received18-OCT-2019State -
11116928949858SIAState Violation/Reminder Notice16-JAN-2019State -
11116868948906SOXState Compliance achieved13-JUL-2006State -
11111978943793SOXState Compliance achieved14-NOV-1996State -
99999979999997SFLState Administrative/Compliance Order without penalty issued29-JUN-1993ODSWeb -
  • 1 - 8 of 8

PWS Facilities


All Facilities

Facility NameFacility IDIs SourceFacility Type DescriptionWater Type DescriptionAvailability DescriptionFacility Activity Status
LAKEVILLE RESERVOIR #2 INTAKE23459YesIntakeSurface waterPermanentActive
SALISBURY WELL D27693YesWell Ground waterPermanentActive
SALISBURY WELL C27692YesWell Ground waterPermanentActive
SALISBURY WELL A27691YesWell Ground waterPermanentActive
SALISBURY WELL B27690YesWell Ground waterPermanentActive
LAKEVILLE WELL #327689YesWell Ground waterPermanentActive
LAKEVILLE WELL #2A27688YesWell Ground waterPermanentActive
LAKEVILLE WELL #127687YesWell Ground waterPermanentActive
KENT RESERVOIR32729YesReservoirSurface waterPermanentInactive
LAKEVILLE RESERVOIR #332504YesReservoirSurface waterPermanentActive
LAKEVILLE RESERVOIR #232503YesReservoirSurface waterPermanentActive
LAKEVILLE WELLFIELD CLEARWELL59368NoClear Well - - Active
SALISBURY WELLFIELD CLEARWELL59370NoClear Well - - Active
LAKEVILLE SWTP CLEARWELL59376NoClear Well - - Active
DISTRIBUTION SYSTEM23460NoDistribution System/Zone - - Active
PETTEE ST PUMP STATION59372NoPump Facility - - Active
LAKEVILLE RES WTP ENTRY POINT38074NoSampling Station - - Active
SUPERNATANT/DECANT SAMPLE TAP46225NoSampling Station - - Active
SUPERNATANT/RAW COMBO SAMPLE TAP46226NoSampling Station - - Active
LAKEVILLE WELLFIELD TP ENTRY POINT46227NoSampling Station - - Active
LAKEVILLE WELLFIELD RAW SAMPLE TAP46228NoSampling Station - - Active
SALISBURY WELLFIELD TP ENTRY POINT46231NoSampling Station - - Active
SALISBURY WELLS A/B RAW SAMPLE TAP46232NoSampling Station - - Active
SALISBURY WELLS C/D RAW SAMPLE TAP46233NoSampling Station - - Active
BUNKER HILL (SALISBURY) TANK59374NoStorage - - Active
LAKEVILLE SWTP TANK59378NoStorage - - Active
LAKEVILLE SURFACE WATER TREATMENT PLANT36514NoTreatment Plant - - Active
SALISBURY WELLFIELD TREATMENT PLANT36515NoTreatment Plant - - Active
LAKEVILLE WELLFIELD TREATMENT PLANT46230NoTreatment Plant - - Active
  • 1 - 29 of 29

PWS Treatment Processes


Treatment Processes

Facility NameFacility IDTreatment ProcessTreatment Objective
LAKEVILLE SURFACE WATER TREATMENT PLANT36514pH Adjustment, PostCorrosion control
LAKEVILLE SURFACE WATER TREATMENT PLANT36514Hypochlorination, PostDisinfection
LAKEVILLE SURFACE WATER TREATMENT PLANT36514CoagulationParticulate removal
LAKEVILLE SURFACE WATER TREATMENT PLANT36514pH Adjustment, PreParticulate removal
LAKEVILLE SURFACE WATER TREATMENT PLANT36514Rapid MixParticulate removal
LAKEVILLE SURFACE WATER TREATMENT PLANT36514FlocculationParticulate removal
LAKEVILLE SURFACE WATER TREATMENT PLANT36514SedimentationParticulate removal
LAKEVILLE SURFACE WATER TREATMENT PLANT36514Filtration, Rapid SandParticulate removal
LAKEVILLE SURFACE WATER TREATMENT PLANT36514Inhibitor, OrthophosphateCorrosion control
LAKEVILLE SURFACE WATER TREATMENT PLANT36514Inhibitor, PolyphosphateCorrosion control
SALISBURY WELLFIELD TREATMENT PLANT36515Hypochlorination, PostDisinfection
SALISBURY WELLFIELD TREATMENT PLANT36515SequestrationSoftening (hardness removal)
SALISBURY WELLFIELD TREATMENT PLANT36515Aeration, DiffusedOrganics removal
SALISBURY WELLFIELD TREATMENT PLANT36515Inhibitor, OrthophosphateCorrosion control
SALISBURY WELLFIELD TREATMENT PLANT36515Inhibitor, PolyphosphateCorrosion control
LAKEVILLE WELLFIELD TREATMENT PLANT46230Hypochlorination, PostDisinfection
LAKEVILLE WELLFIELD TREATMENT PLANT46230Aeration, DiffusedCorrosion control
LAKEVILLE WELLFIELD TREATMENT PLANT462304-Log Treatment of VirusesDisinfection
LAKEVILLE WELLFIELD TREATMENT PLANT46230Inhibitor, PolyphosphateCorrosion control
LAKEVILLE WELLFIELD TREATMENT PLANT46230Inhibitor, OrthophosphateCorrosion control
  • 1 - 20 of 20

For more information on a Water System:
Ask the operators of your water system, contact your primacy agency or file a Freedom of Information Act (FOIA) request.
Drinking water in general: Find out more about your drinking water web site or call the Safe Drinking Water Hotline (1-800-426-4791). EPA has also prepared a table about various regulated drinking water contaminants.
Tools for accessing EPA drinking water data: Safe Drinking Water Information System (SDWIS) Federal Reporting Services and Drinking Water Performance and Results Report.
Research Data: As well as monitoring the levels of drinking water contaminants for which EPA has set standards, EPA, states, and water systems also carry out studies of contaminants that may need to be regulated in the future. For more information about these contaminants, please see the National Contaminant Occurrence Database.