U.S. flag

An official website of the United States government

Safe Drinking Water Information System (SDWIS) Federal Reporting Services

Your Drinking Water Query results from SDWIS Fed Reporting Services

PWS IDCT0740011
PWS NameAQUARION-LITCHFIELD REGIONAL
PWS TypeCommunity water system
Owner TypePrivate
Primary SourceSurface water purchased
Primacy TypeState
Is Wholesaler?No
Population Served3097
County ServedLitchfield

Note


The tables below list all violations that the state reported to EPA for this water system. Health-based violations are listed first, followed by treatment technique, MRDL, monitoring, reporting, and other violations.

Health-based Violations of maximum contaminant levels (MCLs) or maximum residual disinfectant levels (MRDLs), which specify the highest concentrations of contaminants or disinfectants, respectively, allowed in drinking water; or of treatment technique (TT) rules, which specify required processes intended to reduce the amounts of contaminants in drinking water. MCLs, MRDLs, and treatment technique rules are all health-based drinking water standards.
Maximum Contaminant Level or MCL The highest level of a contaminant that is allowed in drinking water. MCLs are set as close to the MCLGs as feasible using the best available treatment technology.
Treatment Technique A required process intended to reduce the level of a contaminant in drinking water.
Maximum residual disinfectant level or MRDL The highest level of a disinfectant allowed in drinking water. There is convincing evidence that addition of a disinfectant is necessary for control of microbial contaminants.
Monitoring & reporting Failure to conduct regular monitoring of drinking water quality, as required by SDWA, or to submit monitoring results in a timely fashion to the primacy agency or EPA.
Public notification & other Failure to provide notification to the public as required by the Violations of Public Notification Rule and the Consumer Confidence Report Rule, and violations of other requirements such as those violations related to variances and exemptions.

PWS Violation


Violations

Violation Category CodeViolation Type DescriptionRule NameContaminant NameViolation IDCompliance Status DescriptionCompliance Period Begin DateCompliance Period End DateIs Health Based Ind
MRLead Consumer NoticeLead and Copper RuleLead and Copper Rule45212Returned to Compliance30-DEC-2019 - No
OtherConsumer Confidence Report Complete Failure to ReportConsumer Confidence RuleConsumer Confidence Rule45211Returned to Compliance01-JUL-2018 - No
OtherConsumer Confidence Report Inadequate ReportingConsumer Confidence RuleConsumer Confidence Rule45207Returned to Compliance10-AUG-2016 - No
OtherConsumer Confidence Report Complete Failure to ReportConsumer Confidence RuleConsumer Confidence Rule45208Returned to Compliance01-JUL-2016 - No
OtherConsumer Confidence Report Complete Failure to ReportConsumer Confidence RuleConsumer Confidence Rule45205Returned to Compliance01-JUL-2014 - No
OtherConsumer Confidence Report Complete Failure to ReportConsumer Confidence RuleConsumer Confidence Rule44506Returned to Compliance01-JUL-2006 - No
  • 1 - 6 of 6

Enforcement Actions


Enforcement Actions

Latest Enforcement IDAssociated To Violation IDEnforcement Action Type CodeEnforcement Action DescriptionEnforcement DateOriginator DescriptionEnforcement Comment
59945212SOXState Compliance achieved16-JAN-2020State -
59745211SIAState Violation/Reminder Notice16-JAN-2019State -
59045208SIAState Violation/Reminder Notice23-FEB-2017State -
59145207SOXState Compliance achieved23-FEB-2017State -
58845205SIAState Violation/Reminder Notice14-JAN-2015State -
40744506SIAState Violation/Reminder Notice13-OCT-2006State -
  • 1 - 6 of 6

PWS Facilities


All Facilities

Facility NameFacility IDIs SourceFacility Type DescriptionWater Type DescriptionAvailability DescriptionFacility Activity Status
INTERCONNECTION - TORRINGTON WATER CO.46047YesConsecutive ConnectionSurface waterPermanentActive
CIRCLE DRIVE WELL #259919YesWell Ground waterPermanentInactive
CIRCLE DRIVE WELL #159918YesWell Ground waterPermanentInactive
GOSHEN WELL #3-200045485YesWell Ground waterPermanentInactive
GOSHEN WELL #127726YesWell Ground waterPermanentInactive
GOSHEN WELL #1-200348131YesWell Ground waterPermanentActive
HAMILL WELL #227872YesWell Ground waterPermanentActive
DUDLEY STREET WELL48626YesWell Ground waterOtherInactive
BERTACCINNI WELL48624YesWell Ground waterOtherInactive
GOSHEN WELL #2-201058005YesWell Ground waterEmergencyInactive
HAMILL WELL #327873YesWell Ground waterEmergencyInactive
GOSHEN WELL #227724YesWell Ground waterEmergencyInactive
LITCHFIELD RESERVOIR48628YesReservoirSurface waterOtherInactive
DISTRIBUTION SYSTEM21668NoDistribution System/Zone - - Active
GOSHEN WELLFIELD BOOSTER PS60145NoPump Facility - - Active
HAMILL WELLFIELD BOOSTER PS60147NoPump Facility - - Active
HAMILL WELLFIELD TP ENTRY POINT45987NoSampling Station - - Active
GOSHEN WELLFIELD RAW SAMPLE TAP45988NoSampling Station - - Active
HAMILL WELLFIELD RAW SAMPLE TAP45989NoSampling Station - - Active
GOSHEN WELLFIELD TP ENTRY POINT58003NoSampling Station - - Active
GOSHEN WELLFIELD TP ENTRY POINT38491NoSampling Station - - Inactive
CIRCLE DRIVE WELLFIELD ENTRY POINT59920NoSampling Station - - Inactive
LITCHFIELD TANK37091NoStorage - - Active
GOSHEN WELLFIELD TANK60137NoStorage - - Active
HAMILL WELLFIELD TANK #160139NoStorage - - Active
HAMILL WELLFIELD TANK #260141NoStorage - - Active
CIRCLE DRIVE WELLFIELD TANK60143NoStorage - - Inactive
GOSHEN WELLFIELD TREATMENT PLANT36366NoTreatment Plant - - Active
HAMILL WELLFIELD TREATMENT PLANT36367NoTreatment Plant - - Active
  • 1 - 29 of 29

PWS Treatment Processes


Treatment Processes

Facility NameFacility IDTreatment ProcessTreatment Objective
GOSHEN WELLFIELD TREATMENT PLANT36366Aeration, DiffusedRadionuclides removal
GOSHEN WELLFIELD TREATMENT PLANT36366Hypochlorination, PostDisinfection
GOSHEN WELLFIELD TREATMENT PLANT36366SequestrationIron removal
GOSHEN WELLFIELD TREATMENT PLANT36366SequestrationManganese removal
GOSHEN WELLFIELD TREATMENT PLANT36366Inhibitor, PolyphosphateCorrosion control
GOSHEN WELLFIELD TREATMENT PLANT36366Inhibitor, OrthophosphateCorrosion control
HAMILL WELLFIELD TREATMENT PLANT36367Hypochlorination, PostDisinfection
HAMILL WELLFIELD TREATMENT PLANT36367SequestrationIron removal
HAMILL WELLFIELD TREATMENT PLANT36367SequestrationManganese removal
HAMILL WELLFIELD TREATMENT PLANT36367Inhibitor, OrthophosphateCorrosion control
HAMILL WELLFIELD TREATMENT PLANT36367Inhibitor, PolyphosphateCorrosion control
  • 1 - 11 of 11

For more information on a Water System:
Ask the operators of your water system, contact your primacy agency or file a Freedom of Information Act (FOIA) request.
Drinking water in general: Find out more about your drinking water web site or call the Safe Drinking Water Hotline (1-800-426-4791). EPA has also prepared a table about various regulated drinking water contaminants.
Tools for accessing EPA drinking water data: Safe Drinking Water Information System (SDWIS) Federal Reporting Services and Drinking Water Performance and Results Report.
Research Data: As well as monitoring the levels of drinking water contaminants for which EPA has set standards, EPA, states, and water systems also carry out studies of contaminants that may need to be regulated in the future. For more information about these contaminants, please see the National Contaminant Occurrence Database.