PWS IDCA4810003
PWS NameCITY OF FAIRFIELD
PWS TypeCommunity water system
Owner TypeLocal government
Primary SourceSurface water
Primacy TypeState
Is Wholesaler?Yes
Population Served120377
County ServedSolano

Note


The tables below list all violations that the state reported to EPA for this water system. Health-based violations are listed first, followed by treatment technique, MRDL, monitoring, reporting, and other violations.

Health-based Violations of maximum contaminant levels (MCLs) or maximum residual disinfectant levels (MRDLs), which specify the highest concentrations of contaminants or disinfectants, respectively, allowed in drinking water; or of treatment technique (TT) rules, which specify required processes intended to reduce the amounts of contaminants in drinking water. MCLs, MRDLs, and treatment technique rules are all health-based drinking water standards.
Maximum Contaminant Level or MCL The highest level of a contaminant that is allowed in drinking water. MCLs are set as close to the MCLGs as feasible using the best available treatment technology.
Treatment Technique A required process intended to reduce the level of a contaminant in drinking water.
Maximum residual disinfectant level or MRDL The highest level of a disinfectant allowed in drinking water. There is convincing evidence that addition of a disinfectant is necessary for control of microbial contaminants.
Monitoring & reporting Failure to conduct regular monitoring of drinking water quality, as required by SDWA, or to submit monitoring results in a timely fashion to the primacy agency or EPA.
Public notification & other Failure to provide notification to the public as required by the Violations of Public Notification Rule and the Consumer Confidence Report Rule, and violations of other requirements such as those violations related to variances and exemptions.

PWS Violation


Violations

Violation Category CodeViolation Type DescriptionRule NameContaminant NameViolation IDCompliance Status DescriptionCompliance Period Begin DateCompliance Period End DateIs Health Based Ind
RPTLSL ReportingLead and Copper Rule RevisionsLEAD AND COPPER RULE REVISIONS9904007Open17-OCT-2024 - No
TTLSL InventoryLead and Copper Rule RevisionsLEAD AND COPPER RULE REVISIONS9904008Open17-OCT-2024 - Yes
MRMonitoring of Treatment (SWTR-Filter)Surface Water Treatment RuleSurface Water Treatment Rule804006Returned to Compliance01-DEC-200731-DEC-2007No
MCLMaximum Contaminant Level Violation, Acute (TCR)Total Coliform RuleColiform (TCR)9904005Returned to Compliance01-MAY-199931-MAY-1999Yes
  • 1 - 4 of 4

Enforcement Actions


Enforcement Actions

Latest Enforcement IDAssociated To Violation IDEnforcement Action Type CodeEnforcement Action DescriptionEnforcement DateOriginator DescriptionEnforcement Comment
804012804006SOXState Compliance achieved21-DEC-2007State -
99040119904005SOXState Compliance achieved30-JUN-1999StateThis TCR violation has been closed with this SOX enforcement record due to rTCR implementation on 4/1/2016.
  • 1 - 2 of 2

PWS Facilities


All Facilities

Facility NameFacility IDIs SourceFacility Type DescriptionWater Type DescriptionAvailability DescriptionFacility Activity Status
DICKSON HILL WTP-FINISHED - DESTROYED32497YesIntakeSurface waterOtherInactive
WATERMAN WTP - PUTAH SOUTH CANAL - RAW32503YesIntakeSurface waterPermanentActive
NBR WTP - PUTAH SOUTH CANAL - RAW32502YesIntakeSurface waterPermanentActive
NBR WTP - NORTH BAY AQUEDUCT - RAW32501YesIntakeSurface waterPermanentActive
UNUSED32500YesIntakeSurface waterOtherInactive
DICKSON HILL WTP-RAW-PUTAH SO.-DESTROYED32498YesIntakeSurface waterOtherInactive
DISTRIBUTION SYSTEM32499NoDistribution System/Zone - - Active
NORTH BAY REGIONAL WTP - TREATED1327NoTreatment Plant - - Active
WATERMAN WTP-FINISHED WATER1328NoTreatment Plant - - Active
  • 1 - 9 of 9

PWS Treatment Processes


Treatment Processes

Facility NameFacility IDTreatment ProcessTreatment Objective
NORTH BAY REGIONAL WTP - TREATED1327pH AdjustmentCorrosion control
NORTH BAY REGIONAL WTP - TREATED1327Ozonation, PostDisinfection by-products control
NORTH BAY REGIONAL WTP - TREATED1327Hypochlorination, PostDisinfection
WATERMAN WTP-FINISHED WATER1328pH AdjustmentCorrosion control
WATERMAN WTP-FINISHED WATER1328Hypochlorination, PostDisinfection
WATERMAN WTP-FINISHED WATER1328Ozonation, PreOrganics removal
  • 1 - 6 of 6

For more information on a Water System:
Ask the operators of your water system, contact your primacy agency or file a Freedom of Information Act (FOIA) request.
Drinking water in general: Find out more about your drinking water web site or call the Safe Drinking Water Hotline (1-800-426-4791). EPA has also prepared a table about various regulated drinking water contaminants.
Tools for accessing EPA drinking water data: Safe Drinking Water Information System (SDWIS) Federal Reporting Services and Drinking Water Performance and Results Report.
Research Data: As well as monitoring the levels of drinking water contaminants for which EPA has set standards, EPA, states, and water systems also carry out studies of contaminants that may need to be regulated in the future. For more information about these contaminants, please see the National Contaminant Occurrence Database.