U.S. flag

An official website of the United States government

Safe Drinking Water Information System (SDWIS) Federal Reporting Services

Your Drinking Water Query results from SDWIS Fed Reporting Services

PWS IDCA4210007
PWS NameMONTECITO WATER DIST
PWS TypeCommunity water system
Owner TypeLocal government
Primary SourceSurface water
Primacy TypeState
Is Wholesaler?No
Population Served11962
County ServedSanta Barbara

Note


The tables below list all violations that the state reported to EPA for this water system. Health-based violations are listed first, followed by treatment technique, MRDL, monitoring, reporting, and other violations.

Health-based Violations of maximum contaminant levels (MCLs) or maximum residual disinfectant levels (MRDLs), which specify the highest concentrations of contaminants or disinfectants, respectively, allowed in drinking water; or of treatment technique (TT) rules, which specify required processes intended to reduce the amounts of contaminants in drinking water. MCLs, MRDLs, and treatment technique rules are all health-based drinking water standards.
Maximum Contaminant Level or MCL The highest level of a contaminant that is allowed in drinking water. MCLs are set as close to the MCLGs as feasible using the best available treatment technology.
Treatment Technique A required process intended to reduce the level of a contaminant in drinking water.
Maximum residual disinfectant level or MRDL The highest level of a disinfectant allowed in drinking water. There is convincing evidence that addition of a disinfectant is necessary for control of microbial contaminants.
Monitoring & reporting Failure to conduct regular monitoring of drinking water quality, as required by SDWA, or to submit monitoring results in a timely fashion to the primacy agency or EPA.
Public notification & other Failure to provide notification to the public as required by the Violations of Public Notification Rule and the Consumer Confidence Report Rule, and violations of other requirements such as those violations related to variances and exemptions.

PWS Violation


Violations

Violation Category CodeViolation Type DescriptionRule NameContaminant NameViolation IDCompliance Status DescriptionCompliance Period Begin DateCompliance Period End DateIs Health Based Ind
MRMonitoring of Treatment (SWTR-Filter)Surface Water Treatment RuleSurface Water Treatment Rule9706005Known01-MAR-202431-MAR-2024No
MCLMaximum Contaminant Level Violation, AverageStage 2 Disinfectants and Disinfection Byproducts RuleTTHM9706003Returned to Compliance01-APR-201530-JUN-2015Yes
TTTreatment Technique (SWTR and GWR)Surface Water Treatment RuleSurface Water Treatment Rule9706002Returned to Compliance01-MAR-199731-MAR-1997Yes
TTTreatment Technique (SWTR and GWR)Surface Water Treatment RuleSurface Water Treatment Rule9306001Returned to Compliance01-JUL-199331-JUL-1993Yes
  • 1 - 4 of 4

Enforcement Actions


Enforcement Actions

Latest Enforcement IDAssociated To Violation IDEnforcement Action Type CodeEnforcement Action DescriptionEnforcement DateOriginator DescriptionEnforcement Comment
99060119706005SFLState Administrative/Compliance Order without penalty issued16-APR-2024StateFailure to collect raw water coliform samples from the raw water sources prior to surface water treatment plant operation
99060099706003SOXState Compliance achieved01-JUL-2015State06_15C_007
97060069706002SFJState Formal Notice of Violation issued16-APR-1997StateENF_NO:04-06-97C-017; SWTR FAILURE - DISINFECTION
95060059306001SOXState Compliance achieved28-JAN-1991State -
  • 1 - 4 of 4

PWS Facilities


All Facilities

Facility NameFacility IDIs SourceFacility Type DescriptionWater Type DescriptionAvailability DescriptionFacility Activity Status
CATER TP TREATED XCLD31513YesConsecutive ConnectionSurface waterPermanentActive
T MOSBY WELL63783YesWell Ground waterPermanentActive
PADEN WELL #257109YesWell Ground waterPermanentActive
ENNISBROOK WELL 02 (1984)13505YesWell Ground waterPermanentActive
AMAPOLA WELL13502YesWell Ground waterPermanentActive
ENNISBROOK WELL 05 (1990) - ACTIVE13501YesWell Ground waterPermanentActive
PADEN WELL - LAS ENTRADAS NO 1-ACTIVECA4210007017YesWell Ground waterOtherInactive
EVR WELL 08 - ABANDONED7913YesWell Ground waterOtherInactive
EVR WELL 07 - ABANDONED7912YesWell Ground waterOtherInactive
ENNISBROOK WELL 03 (1989) - ABANDONED7909YesWell Ground waterOtherInactive
SEAVIEW 02 (WEST) - ABANDONED7878YesWell Ground waterOtherInactive
LAS ENTRADAS WELL 02 (1985) - INACTIVE24401YesWell Ground waterOtherInactive
SEAVIEW 01 (EAST) - INACTIVE21319YesWell Ground waterOtherInactive
VALLEY CLUB ROAD WELL - INACTIVE21313YesWell Ground waterOtherInactive
UNDERWOOD WELL (1985) - INACTIVE21309YesWell Ground waterOtherInactive
PICAY WELL - INACTIVE21302YesWell Ground waterOtherInactive
OFFICE WELL - INACTIVE21301YesWell Ground waterOtherInactive
NEAL WELL - INACTIVE21277YesWell Ground waterOtherInactive
LIVE OAKS WELL - INACTIVE21253YesWell Ground waterOtherInactive
HODGES WELL - INACTIVE21250YesWell Ground waterOtherInactive
EVR WELL 06 - INACTIVE21249YesWell Ground waterOtherInactive
MORGAN WELL - INACTIVE21246YesWell Ground waterOtherInactive
PADEN WELL - LAS ENTRADAS NO 1- INACTIVE13242YesWell Ground waterOtherInactive
JAMESON LAKE RAW31519YesIntakeSurface waterPermanentActive
FOX CANYON (MORRIS CREEK)31518YesIntakeSurface waterPermanentActive
DOULTON TP - RAW31517YesIntakeSurface waterPermanentActive
DOULTON TUNNEL SOUTH PORTAL31516YesIntakeSurface waterPermanentActive
BELLA VISTA TP - RAW31512YesIntakeSurface waterPermanentActive
CCWA - TREATED XCLD31514YesConsecutive ConnectionSurface waterPermanentActive
SCC BLENDED WATER67004YesConsecutive ConnectionSurface waterPermanentActive
ENNISBROOK WELL 2/CISTERN BLEND58077NoCistern - - Active
DISTRIBUTION SYSTEM31515NoDistribution System/Zone - - Active
ENNISBROOK WELL 02 - CL2 & FE/MN FP228NoTreatment Plant - - Active
BELLA VISTA TP - TREATED229NoTreatment Plant - - Active
DOULTON TUNNEL TP - TREATED230NoTreatment Plant - - Active
AMAPOLA WELL - TRT CL451NoTreatment Plant - - Active
PADEN WELL #2 - TRT FE_MN, CL57110NoTreatment Plant - - Active
ENNISBROOK WELL 05 (1990) - TRT CL257566NoTreatment Plant - - Active
PADEN WELL 2 FINAL BLEND57839NoTreatment Plant - - Active
ENNISBROOK WELL 5 - FINAL BLEND58078NoTreatment Plant - - Active
T. MOSBY WELL BLEND - FINAL64600NoTreatment Plant - - Active
PADEN/LAS ENTRADAS-TRT FE/MN CL2227NoTreatment Plant - - Inactive
MORGAN WELL - INACTIVE - TREATED XCLD6449NoTreatment Plant - - Inactive
VALLEY CLUB ROAD WELL (1985) - TRT CL6461NoTreatment Plant - - Inactive
LAS ENTRADAS WELL 02-CL2 & FE/MN FP7203NoTreatment Plant - - Inactive
  • 1 - 45 of 45

PWS Treatment Processes


Treatment Processes

Facility NameFacility IDTreatment ProcessTreatment Objective
ENNISBROOK WELL 02 - CL2 & FE/MN FP228Filtration, Pressure SandIron removal
BELLA VISTA TP - TREATED229FlocculationParticulate removal
BELLA VISTA TP - TREATED229FilteredParticulate removal
BELLA VISTA TP - TREATED229CoagulationParticulate removal
BELLA VISTA TP - TREATED229Hypochlorination, PostDisinfection
BELLA VISTA TP - TREATED229Hypochlorination, PreDisinfection
DOULTON TUNNEL TP - TREATED230FilteredParticulate removal
DOULTON TUNNEL TP - TREATED230Hypochlorination, PostDisinfection
DOULTON TUNNEL TP - TREATED230FlocculationParticulate removal
DOULTON TUNNEL TP - TREATED230CoagulationParticulate removal
DOULTON TUNNEL TP - TREATED230Hypochlorination, PreDisinfection
AMAPOLA WELL - TRT CL451Hypochlorination, PreDisinfection
PADEN WELL #2 - TRT FE_MN, CL57110Filtration, GreensandManganese removal
ENNISBROOK WELL 05 (1990) - TRT CL257566Hypochlorination, PostDisinfection
PADEN WELL 2 FINAL BLEND57839Rapid MixManganese removal
ENNISBROOK WELL 5 - FINAL BLEND58078Rapid MixSoftening (hardness removal)
T. MOSBY WELL BLEND - FINAL64600Rapid MixInorganics removal
T. MOSBY WELL BLEND - FINAL64600Hypochlorination, PostDisinfection
LAS ENTRADAS WELL 02-CL2 & FE/MN FP7203Hypochlorination, PreDisinfection
LAS ENTRADAS WELL 02-CL2 & FE/MN FP7203PermanganateIron removal
LAS ENTRADAS WELL 02-CL2 & FE/MN FP7203Filtration, GreensandIron removal
LAS ENTRADAS WELL 02-CL2 & FE/MN FP7203Filtration, GreensandManganese removal
  • 1 - 22 of 22

For more information on a Water System:
Ask the operators of your water system, contact your primacy agency or file a Freedom of Information Act (FOIA) request.
Drinking water in general: Find out more about your drinking water web site or call the Safe Drinking Water Hotline (1-800-426-4791). EPA has also prepared a table about various regulated drinking water contaminants.
Tools for accessing EPA drinking water data: Safe Drinking Water Information System (SDWIS) Federal Reporting Services and Drinking Water Performance and Results Report.
Research Data: As well as monitoring the levels of drinking water contaminants for which EPA has set standards, EPA, states, and water systems also carry out studies of contaminants that may need to be regulated in the future. For more information about these contaminants, please see the National Contaminant Occurrence Database.