U.S. flag

An official website of the United States government

Safe Drinking Water Information System (SDWIS) Federal Reporting Services

Your Drinking Water Query results from SDWIS Fed Reporting Services

PWS IDCA1910189
PWS NameSAN GABRIEL VALLEY WATER CO-MONTEBELLO 1
PWS TypeCommunity water system
Owner TypePrivate
Primary SourceGround water purchased
Primacy TypeState
Is Wholesaler?No
Population Served9630
County ServedLos Angeles

Note


The tables below list all violations that the state reported to EPA for this water system. Health-based violations are listed first, followed by treatment technique, MRDL, monitoring, reporting, and other violations.

Health-based Violations of maximum contaminant levels (MCLs) or maximum residual disinfectant levels (MRDLs), which specify the highest concentrations of contaminants or disinfectants, respectively, allowed in drinking water; or of treatment technique (TT) rules, which specify required processes intended to reduce the amounts of contaminants in drinking water. MCLs, MRDLs, and treatment technique rules are all health-based drinking water standards.
Maximum Contaminant Level or MCL The highest level of a contaminant that is allowed in drinking water. MCLs are set as close to the MCLGs as feasible using the best available treatment technology.
Treatment Technique A required process intended to reduce the level of a contaminant in drinking water.
Maximum residual disinfectant level or MRDL The highest level of a disinfectant allowed in drinking water. There is convincing evidence that addition of a disinfectant is necessary for control of microbial contaminants.
Monitoring & reporting Failure to conduct regular monitoring of drinking water quality, as required by SDWA, or to submit monitoring results in a timely fashion to the primacy agency or EPA.
Public notification & other Failure to provide notification to the public as required by the Violations of Public Notification Rule and the Consumer Confidence Report Rule, and violations of other requirements such as those violations related to variances and exemptions.

PWS Violation


Violations

Violation Category CodeViolation Type DescriptionRule NameContaminant NameViolation IDCompliance Status DescriptionCompliance Period Begin DateCompliance Period End DateIs Health Based Ind
MRMonitoring and Reporting (DBP)Stage 1 Disinfectants and Disinfection Byproducts RuleTTHM922004Returned to Compliance01-JAN-200930-SEP-2009No
MRMonitoring and Reporting (DBP)Stage 1 Disinfectants and Disinfection Byproducts RuleTotal Haloacetic Acids (HAA5)922003Returned to Compliance01-JAN-200930-SEP-2009No
MRMonitoring and Reporting (DBP)Stage 1 Disinfectants and Disinfection Byproducts RuleTTHM822001Returned to Compliance01-DEC-200730-SEP-2008No
MRMonitoring and Reporting (DBP)Stage 1 Disinfectants and Disinfection Byproducts RuleTotal Haloacetic Acids (HAA5)822002Returned to Compliance01-DEC-200730-SEP-2008No
OtherNotification, PublicMiscellaneous Other Rules - 8700806Known01-AUG-198731-AUG-1987No
  • 1 - 5 of 5

Enforcement Actions


Enforcement Actions

Latest Enforcement IDAssociated To Violation IDEnforcement Action Type CodeEnforcement Action DescriptionEnforcement DateOriginator DescriptionEnforcement Comment
9407007822001SOXState Compliance achieved10-OCT-2010State -
9407007822002SOXState Compliance achieved10-OCT-2010State -
1022021922003SOXState Compliance achieved23-NOV-2009StateNOV LTR FAIL TO SUBMIT QTRLY RPTS
1022021922004SOXState Compliance achieved23-NOV-2009StateNOV LTR FAIL TO SUBMIT QTRLY RPTS
  • 1 - 4 of 4

PWS Facilities


All Facilities

Facility NameFacility IDIs SourceFacility Type DescriptionWater Type DescriptionAvailability DescriptionFacility Activity Status
MWD CB-40 - EMERGENCY ONLY28557YesConsecutive ConnectionSurface waterEmergencyActive
WELL M 02-B - DESTROYED18565YesWell Ground waterOtherInactive
WELL M 02-A - DESTROYED18562YesWell Ground waterOtherInactive
M2 CONN-EL MONTE/WHITTIER SYSTEM28556YesConsecutive ConnectionGround waterPermanentActive
DISTRIBUTION SYSTEM28555NoDistribution System/Zone - - Active
  • 1 - 5 of 5

PWS Treatment Processes


Treatment Processes

No treatment process(es) found. EPA has no record of treatment process(es) reported by the primacy agency for this water system.

For more information on a Water System:
Ask the operators of your water system, contact your primacy agency or file a Freedom of Information Act (FOIA) request.
Drinking water in general: Find out more about your drinking water web site or call the Safe Drinking Water Hotline (1-800-426-4791). EPA has also prepared a table about various regulated drinking water contaminants.
Tools for accessing EPA drinking water data: Safe Drinking Water Information System (SDWIS) Federal Reporting Services and Drinking Water Performance and Results Report.
Research Data: As well as monitoring the levels of drinking water contaminants for which EPA has set standards, EPA, states, and water systems also carry out studies of contaminants that may need to be regulated in the future. For more information about these contaminants, please see the National Contaminant Occurrence Database.