PWS IDAR0000493
PWS NameSARDIS WATER ASSOCIATION
PWS TypeCommunity water system
Owner TypeLocal government
Primary SourceSurface water purchased
Primacy TypeState
Is Wholesaler?No
Population Served15660
County ServedGrant, Saline

Note


The tables below list all violations that the state reported to EPA for this water system. Health-based violations are listed first, followed by treatment technique, MRDL, monitoring, reporting, and other violations.

Health-based Violations of maximum contaminant levels (MCLs) or maximum residual disinfectant levels (MRDLs), which specify the highest concentrations of contaminants or disinfectants, respectively, allowed in drinking water; or of treatment technique (TT) rules, which specify required processes intended to reduce the amounts of contaminants in drinking water. MCLs, MRDLs, and treatment technique rules are all health-based drinking water standards.
Maximum Contaminant Level or MCL The highest level of a contaminant that is allowed in drinking water. MCLs are set as close to the MCLGs as feasible using the best available treatment technology.
Treatment Technique A required process intended to reduce the level of a contaminant in drinking water.
Maximum residual disinfectant level or MRDL The highest level of a disinfectant allowed in drinking water. There is convincing evidence that addition of a disinfectant is necessary for control of microbial contaminants.
Monitoring & reporting Failure to conduct regular monitoring of drinking water quality, as required by SDWA, or to submit monitoring results in a timely fashion to the primacy agency or EPA.
Public notification & other Failure to provide notification to the public as required by the Violations of Public Notification Rule and the Consumer Confidence Report Rule, and violations of other requirements such as those violations related to variances and exemptions.

PWS Violation


Violations

  • 1 - 1 of 1

Enforcement Actions


Enforcement Actions

PWS Facilities


All Facilities

Facility NameFacility IDIs SourceFacility Type DescriptionWater Type DescriptionAvailability DescriptionFacility Activity Status
CENTRAL ARKANSAS WATER5480YesConsecutive ConnectionSurface waterPermanentActive
WATER WELL #86932YesWell Ground waterPermanentActive
WATER WELL #76931YesWell Ground waterPermanentActive
WATER WELL #65334YesWell Ground waterPermanentActive
WATER WELL #11918YesWell Ground waterPermanentActive
WATER WELL #41917YesWell Ground waterPermanentActive
WATER WELL #51916YesWell Ground waterPermanentActive
WATER WELL #31915YesWell Ground waterPermanentActive
WATER WELL #21914YesWell Ground waterPermanentActive
SARDIS WATER ASSOCIATION3045NoDistribution System/Zone - - Active
IRON REMOVAL PLANT #1205NoTreatment Plant - - Active
IRON REMOVAL WTP #2206NoTreatment Plant - - Active
IRON REMOVAL WTP #3207NoTreatment Plant - - Active
WTP #56933NoTreatment Plant - - Active
  • 1 - 14 of 14

PWS Treatment Processes


Treatment Processes

Facility NameFacility IDTreatment ProcessTreatment Objective
IRON REMOVAL PLANT #1205Gaseous Chlorination, PostDisinfection
IRON REMOVAL PLANT #1205Gaseous Chlorination, PostDisinfection
IRON REMOVAL PLANT #1205Gaseous Chlorination, PreIron removal
IRON REMOVAL PLANT #1205Aeration, CascadeIron removal
IRON REMOVAL PLANT #1205Filtration, Pressure SandInorganics removal
IRON REMOVAL PLANT #1205FluoridationOther
IRON REMOVAL WTP #2206Gaseous Chlorination, PostDisinfection
IRON REMOVAL WTP #2206Gaseous Chlorination, PostDisinfection
IRON REMOVAL WTP #2206Aeration, Packed TowerIron removal
IRON REMOVAL WTP #2206Gaseous Chlorination, PreIron removal
IRON REMOVAL WTP #2206Filtration, Rapid SandIron removal
IRON REMOVAL WTP #2206FluoridationOther
IRON REMOVAL WTP #3207Gaseous Chlorination, PostDisinfection
IRON REMOVAL WTP #3207Gaseous Chlorination, PostDisinfection
IRON REMOVAL WTP #3207Aeration, Packed TowerIron removal
IRON REMOVAL WTP #3207Gaseous Chlorination, PreIron removal
IRON REMOVAL WTP #3207Filtration, Rapid SandIron removal
IRON REMOVAL WTP #3207FluoridationOther
WTP #56933pH AdjustmentCorrosion control
WTP #56933PermanganateIron removal
WTP #56933SedimentationInorganics removal
WTP #56933FluoridationOther
WTP #56933Hypochlorination, PostDisinfection
WTP #56933Reducing Agent, Sodium BisulfateDe-chlorination
WTP #56933Reducing AgentsOrganics removal
WTP #56933Inhibitor, PolyphosphateCorrosion control
WTP #56933PermanganateManganese removal
WTP #56933SedimentationIron removal
WTP #56933Filtration, Rapid SandIron removal
WTP #56933PermanganateTaste / odor control
  • 1 - 30 of 30

For more information on a Water System:
Ask the operators of your water system, contact your primacy agency or file a Freedom of Information Act (FOIA) request.
Drinking water in general: Find out more about your drinking water web site or call the Safe Drinking Water Hotline (1-800-426-4791). EPA has also prepared a table about various regulated drinking water contaminants.
Tools for accessing EPA drinking water data: Safe Drinking Water Information System (SDWIS) Federal Reporting Services and Drinking Water Performance and Results Report.
Research Data: As well as monitoring the levels of drinking water contaminants for which EPA has set standards, EPA, states, and water systems also carry out studies of contaminants that may need to be regulated in the future. For more information about these contaminants, please see the National Contaminant Occurrence Database.