U.S. flag

An official website of the United States government

Safe Drinking Water Information System (SDWIS) Federal Reporting Services

Your Drinking Water Query results from SDWIS Fed Reporting Services

PWS IDAL0000436
PWS NameLEVEL PLAINS, TOWN OF
PWS TypeCommunity water system
Owner TypeLocal government
Primary SourceGround water
Primacy TypeState
Is Wholesaler?No
Population Served3819
County ServedDale

Note


The tables below list all violations that the state reported to EPA for this water system. Health-based violations are listed first, followed by treatment technique, MRDL, monitoring, reporting, and other violations.

Health-based Violations of maximum contaminant levels (MCLs) or maximum residual disinfectant levels (MRDLs), which specify the highest concentrations of contaminants or disinfectants, respectively, allowed in drinking water; or of treatment technique (TT) rules, which specify required processes intended to reduce the amounts of contaminants in drinking water. MCLs, MRDLs, and treatment technique rules are all health-based drinking water standards.
Maximum Contaminant Level or MCL The highest level of a contaminant that is allowed in drinking water. MCLs are set as close to the MCLGs as feasible using the best available treatment technology.
Treatment Technique A required process intended to reduce the level of a contaminant in drinking water.
Maximum residual disinfectant level or MRDL The highest level of a disinfectant allowed in drinking water. There is convincing evidence that addition of a disinfectant is necessary for control of microbial contaminants.
Monitoring & reporting Failure to conduct regular monitoring of drinking water quality, as required by SDWA, or to submit monitoring results in a timely fashion to the primacy agency or EPA.
Public notification & other Failure to provide notification to the public as required by the Violations of Public Notification Rule and the Consumer Confidence Report Rule, and violations of other requirements such as those violations related to variances and exemptions.

PWS Violation


Violations

Violation Category CodeViolation Type DescriptionRule NameContaminant NameViolation IDCompliance Status DescriptionCompliance Period Begin DateCompliance Period End DateIs Health Based Ind
RPTReport Sample Result/Fail Monitor (RTCR)Revised Total Coliform RuleRevised Total Coliform Rule10597Returned to Compliance11-APR-2022 - No
MCLMaximum Contaminant Level Violation, Acute (TCR)Total Coliform RuleColiform (TCR)10596Known01-MAR-199631-MAR-1996Yes
  • 1 - 2 of 2

Enforcement Actions


Enforcement Actions

Latest Enforcement IDAssociated To Violation IDEnforcement Action Type CodeEnforcement Action DescriptionEnforcement DateOriginator DescriptionEnforcement Comment
4589710597SIAState Violation/Reminder Notice18-APR-2022State -
3869610596SIFState Public Notification received03-APR-1996State**Original Initiator from FRDS '' was unidentified**
  • 1 - 2 of 2

PWS Facilities


All Facilities

Facility NameFacility IDIs SourceFacility Type DescriptionWater Type DescriptionAvailability DescriptionFacility Activity Status
ENTERPRISE10405YesConsecutive ConnectionGround waterEmergencyActive
WELL #4, 300 GPM4116YesWell Ground waterPermanentActive
WELL #3, 200 GPM4115YesWell Ground waterPermanentActive
WELL #2, 180 GPM4114YesWell Ground waterPermanentActive
WELL #1, 150 GPM4113YesWell Ground waterPermanentActive
WELL #5, 500 GPM12238YesWell Ground waterPermanentActive
DALEVILLE DS CONNECTION7008YesConsecutive ConnectionGround waterEmergencyActive
DISTRIBUTION SYSTEM5912NoDistribution System/Zone - - Active
TANK #1, 300,000 GAL632NoStorage - - Active
TANK #2, 150,000 GAL633NoStorage - - Active
WELL #5 TREATMENT PLANT12240NoTreatment Plant - - Active
WELL #1 + TREATMENT PLANT2848NoTreatment Plant - - Active
WELL #2 + TREATMENT PLANT2849NoTreatment Plant - - Active
WELL #3 + TREATMENT PLANT2850NoTreatment Plant - - Active
WELL #4 + TREATMENT PLANT2851NoTreatment Plant - - Active
  • 1 - 15 of 15

PWS Treatment Processes


Treatment Processes

Facility NameFacility IDTreatment ProcessTreatment Objective
WELL #5 TREATMENT PLANT12240Gaseous Chlorination, PostDisinfection
WELL #1 + TREATMENT PLANT2848Gaseous Chlorination, PostDisinfection
WELL #2 + TREATMENT PLANT2849Gaseous Chlorination, PostDisinfection
WELL #3 + TREATMENT PLANT2850Gaseous Chlorination, PostDisinfection
WELL #4 + TREATMENT PLANT2851Gaseous Chlorination, PostDisinfection
  • 1 - 5 of 5

For more information on a Water System:
Ask the operators of your water system, contact your primacy agency or file a Freedom of Information Act (FOIA) request.
Drinking water in general: Find out more about your drinking water web site or call the Safe Drinking Water Hotline (1-800-426-4791). EPA has also prepared a table about various regulated drinking water contaminants.
Tools for accessing EPA drinking water data: Safe Drinking Water Information System (SDWIS) Federal Reporting Services and Drinking Water Performance and Results Report.
Research Data: As well as monitoring the levels of drinking water contaminants for which EPA has set standards, EPA, states, and water systems also carry out studies of contaminants that may need to be regulated in the future. For more information about these contaminants, please see the National Contaminant Occurrence Database.