U.S. flag

An official website of the United States government

Safe Drinking Water Information System (SDWIS) Federal Reporting Services

Your Drinking Water Query results from SDWIS Fed Reporting Services

PWS IDAL0000254
PWS NameFULTON, UTILITIES BOARD OF THE TOWN OF
PWS TypeCommunity water system
Owner TypeLocal government
Primary SourceGround water
Primacy TypeState
Is Wholesaler?No
Population Served534
County ServedClarke

Note


The tables below list all violations that the state reported to EPA for this water system. Health-based violations are listed first, followed by treatment technique, MRDL, monitoring, reporting, and other violations.

Health-based Violations of maximum contaminant levels (MCLs) or maximum residual disinfectant levels (MRDLs), which specify the highest concentrations of contaminants or disinfectants, respectively, allowed in drinking water; or of treatment technique (TT) rules, which specify required processes intended to reduce the amounts of contaminants in drinking water. MCLs, MRDLs, and treatment technique rules are all health-based drinking water standards.
Maximum Contaminant Level or MCL The highest level of a contaminant that is allowed in drinking water. MCLs are set as close to the MCLGs as feasible using the best available treatment technology.
Treatment Technique A required process intended to reduce the level of a contaminant in drinking water.
Maximum residual disinfectant level or MRDL The highest level of a disinfectant allowed in drinking water. There is convincing evidence that addition of a disinfectant is necessary for control of microbial contaminants.
Monitoring & reporting Failure to conduct regular monitoring of drinking water quality, as required by SDWA, or to submit monitoring results in a timely fashion to the primacy agency or EPA.
Public notification & other Failure to provide notification to the public as required by the Violations of Public Notification Rule and the Consumer Confidence Report Rule, and violations of other requirements such as those violations related to variances and exemptions.

PWS Violation


Violations

Violation Category CodeViolation Type DescriptionRule NameContaminant NameViolation IDCompliance Status DescriptionCompliance Period Begin DateCompliance Period End DateIs Health Based Ind
MCLMaximum Contaminant Level Violation, Monthly (TCR)Total Coliform RuleColiform (TCR)75305Known01-FEB-200528-FEB-2005Yes
MCLMaximum Contaminant Level Violation, Monthly (TCR)Total Coliform RuleColiform (TCR)25402Known01-JUL-200231-JUL-2002Yes
MRMonitoring, Routine Minor (TCR)Total Coliform RuleColiform (TCR)4394Known01-NOV-199330-NOV-1993No
MRMonitoring, Routine Minor (TCR)Total Coliform RuleColiform (TCR)794Known01-OCT-199331-OCT-1993No
MRMonitoring, Routine Minor (TCR)Total Coliform RuleColiform (TCR)75292Known01-JUN-199230-JUN-1992No
  • 1 - 5 of 5

Enforcement Actions


Enforcement Actions

Latest Enforcement IDAssociated To Violation IDEnforcement Action Type CodeEnforcement Action DescriptionEnforcement DateOriginator DescriptionEnforcement Comment
10040575305SIFState Public Notification received01-APR-2005State -
2350225402SIFState Public Notification received23-SEP-2002StateJULY 2002 BACTERIOLOGICAL MCL VIOLATION
301944394SIFState Public Notification received09-FEB-1994State**Original Initiator from FRDS '' was unidentified**
12094794SIFState Public Notification received30-NOV-1993State**Original Initiator from FRDS '' was unidentified**
10019275292SIFState Public Notification received06-AUG-1992State**Original Initiator from FRDS '' was unidentified**
  • 1 - 5 of 5

PWS Facilities


All Facilities

Facility NameFacility IDIs SourceFacility Type DescriptionWater Type DescriptionAvailability DescriptionFacility Activity Status
MID-CENTRAL WATER & FPA7852YesConsecutive ConnectionGround waterEmergencyActive
WELL 23912YesWell Ground waterPermanentActive
WELL 1 INACTIVE (NOT IN USE)3911YesWell Ground waterOtherInactive
WELL #2 - CLEARWELL 111951NoClear Well - - Active
DISTRIBUTION SYSTEM5780NoDistribution System/Zone - - Active
TANK 1378NoStorage - - Active
WELL 2 TREATMENT PLANT2715NoTreatment Plant - - Active
  • 1 - 7 of 7

PWS Treatment Processes


Treatment Processes

Facility NameFacility IDTreatment ProcessTreatment Objective
WELL 2 TREATMENT PLANT2715PermanganateIron removal
WELL 2 TREATMENT PLANT2715Aeration, CascadeIron removal
WELL 2 TREATMENT PLANT2715Filtration, Pressure SandIron removal
WELL 2 TREATMENT PLANT2715Gaseous Chlorination, PostDisinfection
  • 1 - 4 of 4

For more information on a Water System:
Ask the operators of your water system, contact your primacy agency or file a Freedom of Information Act (FOIA) request.
Drinking water in general: Find out more about your drinking water web site or call the Safe Drinking Water Hotline (1-800-426-4791). EPA has also prepared a table about various regulated drinking water contaminants.
Tools for accessing EPA drinking water data: Safe Drinking Water Information System (SDWIS) Federal Reporting Services and Drinking Water Performance and Results Report.
Research Data: As well as monitoring the levels of drinking water contaminants for which EPA has set standards, EPA, states, and water systems also carry out studies of contaminants that may need to be regulated in the future. For more information about these contaminants, please see the National Contaminant Occurrence Database.