U.S. flag

An official website of the United States government

Safe Drinking Water Information System (SDWIS) Federal Reporting Services

Your Drinking Water Query results from SDWIS Fed Reporting Services

PWS IDAL0000048
PWS NameLOXLEY, CITY OF
PWS TypeCommunity water system
Owner TypeLocal government
Primary SourceGround water
Primacy TypeState
Is Wholesaler?No
Population Served10104
County ServedBaldwin

Note


The tables below list all violations that the state reported to EPA for this water system. Health-based violations are listed first, followed by treatment technique, MRDL, monitoring, reporting, and other violations.

Health-based Violations of maximum contaminant levels (MCLs) or maximum residual disinfectant levels (MRDLs), which specify the highest concentrations of contaminants or disinfectants, respectively, allowed in drinking water; or of treatment technique (TT) rules, which specify required processes intended to reduce the amounts of contaminants in drinking water. MCLs, MRDLs, and treatment technique rules are all health-based drinking water standards.
Maximum Contaminant Level or MCL The highest level of a contaminant that is allowed in drinking water. MCLs are set as close to the MCLGs as feasible using the best available treatment technology.
Treatment Technique A required process intended to reduce the level of a contaminant in drinking water.
Maximum residual disinfectant level or MRDL The highest level of a disinfectant allowed in drinking water. There is convincing evidence that addition of a disinfectant is necessary for control of microbial contaminants.
Monitoring & reporting Failure to conduct regular monitoring of drinking water quality, as required by SDWA, or to submit monitoring results in a timely fashion to the primacy agency or EPA.
Public notification & other Failure to provide notification to the public as required by the Violations of Public Notification Rule and the Consumer Confidence Report Rule, and violations of other requirements such as those violations related to variances and exemptions.

PWS Violation


Violations

Violation Category CodeViolation Type DescriptionRule NameContaminant NameViolation IDCompliance Status DescriptionCompliance Period Begin DateCompliance Period End DateIs Health Based Ind
MRMonitoring, Routine Minor (TCR)Total Coliform RuleColiform (TCR)37702Known01-JUL-200631-JUL-2006No
MRMonitoring, Repeat Minor (TCR)Total Coliform RuleColiform (TCR)37701Known01-MAY-200131-MAY-2001No
  • 1 - 2 of 2

Enforcement Actions


Enforcement Actions

  • 1 - 1 of 1

PWS Facilities


All Facilities

Facility NameFacility IDIs SourceFacility Type DescriptionWater Type DescriptionAvailability DescriptionFacility Activity Status
EAST CENTRAL BALDWIN COUNTY WATER & FPA7934YesConsecutive ConnectionGround water under the influence of surface waterEmergencyActive
WELL #49069YesWell Ground waterPermanentActive
WELL #39068YesWell Ground waterPermanentActive
WELL #23702YesWell Ground waterPermanentActive
WELL #13701YesWell Ground waterOtherInactive
BELFOREST WATER SYSTEM11998YesConsecutive ConnectionGround waterEmergencyActive
NORTH BALDWIN UTILITIES12000YesConsecutive ConnectionGround waterEmergencyActive
ROBERTSDALE UTILITIES7932YesConsecutive ConnectionGround waterEmergencyActive
PLANT #2 - CLEARWELL 111996NoClear Well - - Active
PLANT #3 - CLEARWELL 111997NoClear Well - - Active
PLANT #1 - CLEARWELL 111995NoClear Well - - Inactive
DISTRIBUTION SYSTEM5644NoDistribution System/Zone - - Active
CR 49 N PUMP STATION #19892NoPump Facility - - Active
TANK #185NoStorage - - Active
TANK #286NoStorage - - Active
TANK #387NoStorage - - Active
TANK #488NoStorage - - Active
PLANT #2 (WELL 2)2572NoTreatment Plant - - Active
PLANT #3 (WELL 3, WELL 4)9070NoTreatment Plant - - Active
PLANT #1 (WELL 1)2571NoTreatment Plant - - Inactive
  • 1 - 20 of 20

PWS Treatment Processes


Treatment Processes

Facility NameFacility IDTreatment ProcessTreatment Objective
PLANT #1 (WELL 1)2571Gaseous Chlorination, PostDisinfection
PLANT #1 (WELL 1)2571pH AdjustmentCorrosion control
PLANT #1 (WELL 1)2571Aeration, CascadeOrganics removal
PLANT #1 (WELL 1)2571Aeration, CascadeIron removal
PLANT #2 (WELL 2)2572Gaseous Chlorination, PostDisinfection
PLANT #2 (WELL 2)2572Aeration, CascadeIron removal
PLANT #2 (WELL 2)2572Lime - Soda Ash AdditionSoftening (hardness removal)
PLANT #3 (WELL 3, WELL 4)9070Gaseous Chlorination, PostDisinfection
PLANT #3 (WELL 3, WELL 4)9070Lime - Soda Ash AdditionSoftening (hardness removal)
PLANT #3 (WELL 3, WELL 4)9070Aeration, Packed TowerDisinfection by-products control
  • 1 - 10 of 10

For more information on a Water System:
Ask the operators of your water system, contact your primacy agency or file a Freedom of Information Act (FOIA) request.
Drinking water in general: Find out more about your drinking water web site or call the Safe Drinking Water Hotline (1-800-426-4791). EPA has also prepared a table about various regulated drinking water contaminants.
Tools for accessing EPA drinking water data: Safe Drinking Water Information System (SDWIS) Federal Reporting Services and Drinking Water Performance and Results Report.
Research Data: As well as monitoring the levels of drinking water contaminants for which EPA has set standards, EPA, states, and water systems also carry out studies of contaminants that may need to be regulated in the future. For more information about these contaminants, please see the National Contaminant Occurrence Database.